Omron E5EK-AA2-DRT CompoBus/D-type Digital Controller E5EK Series
-
Dimensions: 4.8cm x 11.35cm x 9.6cm
-
Country of origin: Japan
-
Payment: T/T, Western Union
-
Shipping port: Xiamen
The Omron E5EK-AA2-DRT, also cataloged as the E5EK-AA2 CompoBus/D-type Digital Controller, operates as a dedicated hardware component for closed-loop process control and process parameter digitizing within CompoBus/D (DeviceNet) fieldbus networks. Powered by a supply voltage of 100 to 240 VAC (or 24 VAC/DC), the unit executes process loop control routines across an allowable operating voltage range of 85% to 110%. The controller maintains low power consumption (15 VA max for AC models; 8 W for 24 VDC), transmitting digitized PV/SV dataset profiles to master PLCs.
Part Number Code Structure
- E5EK: Omron 1/8 DIN digital process controller product family.
- AA2: Advanced process control input/output structure specification.
- DRT: Integrated CompoBus/D (DeviceNet) fieldbus communication module prefix.
Technical Performance Metrics
| Parameter | Specification |
|---|---|
| Model | E5EK-AA2-DRT |
| Brand | Omron |
| Origin | Japan |
| Weight | 0.3 kg |
| Shipping Dimensions | 11.35 x 4.8 x 9.6 cm |
| Operating Temp | -10 to 55 deg C |
| Power Consumption | 15 VA (100 to 240 VAC), 12 VA (24 VAC), 8 W (24 VDC) |
| Power Supply Voltage | 100 to 240 VAC (50/60 Hz), 24 VAC/DC |
| Operating Voltage Range | 85% to 110% of rated supply voltage |
| Overall Dimensions | 4.8 x 11.35 x 9.6 cm (WxLxH) |
| Shipping Weight | 2 kg |
Fieldbus Bus Communication & Dynamic Scaling
Connecting directly to DeviceNet trunklines, the controller exchanges cyclic I/O data with remote masters at fast backplane bus communication velocity. High I/O density scaling allows distributed temperature and process loops to transmit setpoints, alarm flags, and real-time process variables without overloading PLC main processing units. Solid-state internal memory preserves firmware flash compatibility during online node reconfiguration and power cycling.
Package & Delivery Contents
- 1 x Omron E5EK-AA2-DRT Digital Controller
- 1 x Panel Mounting Adapter Kit
- 1 x Operating Instruction Manual
Field Installation & Wiring Guidelines
- Panel Cutout Fastening: Insert the 1/8 DIN chassis into the panel cutout and secure with side mounting brackets to ensure tight environmental sealing.
- Power Supply Wiring: Connect AC line voltage (100 to 240 VAC) or 24 VAC/DC power to designated terminals, verifying operating voltage remains within 85% to 110%.
- CompoBus/D Communication Cable: Attach DeviceNet 5-wire shielded drop cable to trunkline connectors; ground shield wire at a single point.
- Sensor Input Isolation: Route thermocouple, RTD, or linear analog input cables away from AC motor drives and high-current power conduits.
- Ground Terminal Connection: Wire the earth protective terminal to the panel grounding bus using a short, low-impedance copper conductor.
Technical Knowledge Base
-
Does the E5EK-AA2-DRT support hot-swapping on active DeviceNet fieldbus trunks?
No. Disconnect power and bus communication connectors before replacing the unit to prevent signal corruption on active trunklines.
-
How does the unit react when supply voltage drops below the 85% operating threshold?
Under-voltage conditions trigger an internal reset mechanism, causing the unit to fail-safe into a hold state and halt control outputs.
-
What precautions prevent noise interference on sensor input channels?
Use shielded twisted-pair cables for analog signals and maintain dedicated conduit separation from high-voltage AC power wiring.
-
How does CompoBus/D communication latency affect process loop execution?
Internal PID loops operate independently of bus update rates, ensuring uninterrupted closed-loop control during network load peaks.
-
Is external power required for the CompoBus/D network transceiver circuit?
Yes. DeviceNet fieldbus communications require 24 VDC bus power supplied separately across the thick/thin trunkline cable.
-
How is firmware consistency maintained across multi-node controller networks?
The unit features non-volatile flash memory, maintaining parameters and firmware flash compatibility during total power outages.
-
What mounting clearance is recommended for effective thermal dissipation?
Maintain minimum 20 mm vertical clearance between adjacent DIN panel cutouts to allow natural convective heat dissipation.
-
Can the controller be powered directly from a 24 VDC battery supply?
Yes. The multi-voltage power supply module accepts nominal 24 VDC inputs within an operating range of 20.4 VDC to 26.4 VDC.
Maxwell PLC is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.