3BDH000723R1 ABB Analog Output Module Advant 800xA
-
Dimensions: 18.5 x 8.5 x 30.5cm
-
Country of origin: Sweden
-
Payment: T/T, Western Union
-
Shipping port: Xiamen
Configured for high-density signal distribution in Advant 800xA systems, the ABB 3BDH000723R1 (CAO10-P Analog Output Module) provides direct physical execution of control commands. This module outputs sixteen independent channels, supporting both 4–20 mA current loops and 0–10 V voltage signals. It processes incoming data from the controller and converts values into precise analog signals for downstream actuators, valves, or positioners. The hardware design facilitates integration into standard DCS backplanes, providing signal isolation and loop-level monitoring to maintain continuous process regulation.
Module Configuration
The CAO10-P is a fixed-hardware unit identified by part number 3BDH000723R1. There are no configurable hardware sub-versions for this module; all performance specifications are determined by the base module design.
Technical Specifications
| Parameter | Specification |
| Model | CAO10-P |
| Part Number | 3BDH000723R1 |
| Brand | ABB |
| Origin | Sweden |
| Weight | 1.08 kg |
| Shipping Dimensions | 18.5 x 8.5 x 30.5 cm |
| Operating Temp | 0 deg C to +60 deg C |
| Power Consumption | 5 W (typical) |
| Output Channels | 16 independent analog outputs |
| Signal Types | 4–20 mA or 0–10 V DC |
| Resolution | 12-bit |
| Electrical Isolation | 500 VAC |
Deterministic Control and Backplane Communication
The module integrates with the Advant 800xA backplane bus communication velocity architecture, ensuring high-speed data transfer between the central processor and the analog output stages. The I/O density scaling allows for sixteen channels to operate simultaneously without bus contention. Firmware flash compatibility is managed through the Advant OCS interface, allowing for system-wide updates without manual intervention at the module level. This integration ensures deterministic network performance when executing time-critical control loops.
Ordering Information
-
CAO10-P Analog Output Module unit
-
Static-dissipative protective packaging
-
Technical documentation/manual insert
-
No mounting base or terminal blocks included (sold separately)
Field Installation Guidelines
-
Grounding: Secure the module to the backplane chassis to establish a common ground connection. Ensure the cabinet earth ground is low-impedance.
-
Wiring Constraints: Limit output loop resistance according to the 4–20 mA loop budget to maintain signal accuracy.
-
Shielding: Utilize shielded twisted-pair cabling for all analog outputs. Terminate shields at the cabinet entry point to suppress electromagnetic interference.
-
Insertion: Ensure the backplane connector is fully seated. Verify that no mechanical obstruction exists in the rack slot before final locking.
Frequently Asked Questions
-
Q: Does the module support hot-swap capability?
-
A: No, module removal requires the rack to be de-energized to prevent short-circuiting the backplane voltage rails or causing signal transients.
-
Q: How are channels configured for 4–20 mA vs 0–10 V?
-
A: Configuration is handled via the 800xA software environment; internal hardware logic switches the output mode per channel.
-
Q: Is HART protocol supported on all 16 channels?
-
A: Yes, the module supports HART 5.0/5.1 communication protocols across all channels for field device diagnostics.
-
Q: What is the maximum load the module can drive?
-
A: Refer to the loop impedance specifications; current output must remain within the compliance voltage limits defined in the technical manual.
-
Q: Does the module provide channel-to-channel isolation?
-
A: The module features 500 VAC electrical isolation; however, specific channel isolation depends on the system grounding scheme.
-
Q: Can this module be configured in a redundant pair?
-
A: Yes, the CAO10-P supports redundant I/O configurations when paired with the appropriate Advant 800xA redundancy hardware and software.
-
Q: How does the system detect an open-loop condition?
-
A: The internal diagnostic logic monitors the return current; an open loop is reported via the controller diagnostic flags in real-time.
-
Q: Is firmware field-upgradeable?
-
A: Yes, firmware can be updated via the Advant 800xA system interface using the standard download procedure.
Maxwell PLC is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.