20F11ND077JA0NNNNN Allen-Bradley PowerFlex 753 AC Drive
-
Dimensions: 29.5 x 40.5 x 17.2 cm
-
Country of origin: USA
-
Payment: T/T, Western Union
-
Shipping port: Xiamen
Configured for high-power motor control in industrial automation, the Allen-Bradley 20F11ND077JA0NNNNN (20F11ND077JA0NNNNN AC Drive) provides direct physical/electrical execution. This PowerFlex 753 drive operates with 480 VAC, 3-phase input and features integrated I/O functionality for localized machine control. The unit utilizes a Frame 5 chassis with standard forced-air cooling, supporting both normal duty and heavy duty application requirements through its variable output current profiles.
Model Matrix & Suffix Breakdown
-
20F: PowerFlex 753 drive series.
-
11N: 480 VAC, 3-phase input with DC terminals.
-
D077: 77 Amps continuous output current (ND).
-
J: Frame 5 chassis size.
-
A0: Filtered EMC option with CM jumper installed.
-
N: Standard protection and forced-air cooling.
-
N: Blank HIM (Human Interface Module).
-
NNN: No additional factory-installed options.
Hardware Specifications
| Parameter | Specification |
| Model | 20F11ND077JA0NNNNN |
| Brand | Allen-Bradley |
| Origin | USA |
| Weight | 6 kg |
| Shipping Dimensions | 29.5 cm x 40.5 cm x 17.2 cm |
| Voltage Rating | 480 VAC / 650 VDC |
| Output Current (ND) | 77 A (60 HP) |
| Output Current (HD) | 65 A (50 HP) |
| Enclosure Type | IP20 / IP00 (Open Type) |
Deterministic Industrial Network Control
The PowerFlex 753 series is engineered for seamless integration into high-speed industrial networks, utilizing EtherNet/IP and related protocols to maintain deterministic communication. The architecture supports advanced I/O density scaling, allowing for the precise configuration of input and output points via the internal backplane bus. Firmware flash compatibility is included, permitting field-side updates to communication stacks and motor control algorithms. This design ensures that motion profiles and setpoints remain synchronized across multi-axis platforms, minimizing command-to-execution latency within the control network.
Ordering Info
-
1 20F11ND077JA0NNNNN AC Drive
-
1 I/O terminal block kit
-
1 Technical installation and safety manual
Field Installation Guidelines
-
Mechanical Mounting
-
Secure the unit vertically on a rigid, flat surface.
-
Maintain minimum airflow clearance zones above and below the Frame 5 chassis to support effective forced-air cooling.
-
Electrical Grounding
-
Terminate all power input and motor leads to the drive’s terminals following specified torque values.
-
Establish a robust connection to the facility earth ground to optimize EMC performance and maintain the functional integrity of the installed CM jumper.
Frequently Asked Questions
-
Does this drive support hot-swappable I/O modules?
No, all I/O cards and control modules must be installed or removed while the drive is de-energized to prevent electrical damage to the backplane communication pins.
-
What is the difference between ND and HD modes?
ND (Normal Duty) supports 77 A for standard constant torque applications, while HD (Heavy Duty) supports 65 A with increased overload capacity for demanding start cycles.
-
Can the CM jumper be removed?
The CM jumper is factory-configured for optimal EMC performance; removing it may increase electrical noise levels and violate regulatory electromagnetic compatibility standards.
-
How is the HIM added if it is currently blank?
A standard PowerFlex 753 HIM can be attached to the front of the drive at any time to provide a local human-machine interface for programming and diagnostics.
-
What protection is provided by the open-type enclosure?
The IP20 open-type enclosure provides limited protection against solid objects larger than 12 mm; it requires installation within a controlled, NEMA-rated cabinet.
-
How is firmware updated?
Firmware updates are performed using the ControlFLASH utility through the drive's communication port; ensure the system is in a safe state before initiating.
-
What triggers the internal thermal fault?
The drive monitors the heatsink temperature; if airflow is blocked or ambient temperature exceeds limits, it will cease operation to protect internal power electronics.
-
Can the DC terminals be used for power supply?
The DC terminals are intended for DC bus sharing or connection to an external braking resistor; do not connect them to an external AC power supply.
Maxwell PLC is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.