1TGE102019R4800 ABB Interfaces Module M-System Series
-
Dimensions: 23.8 x 17 x 10.3cm
-
Country of origin: Sweden
-
Payment: T/T, Western Union
-
Shipping port: Xiamen
Configured for signal translation and power distribution in DCS architectures, the ABB 1TGE102019R4800 (1TGE102019R4800 Interfaces Module) provides direct physical/electrical execution. This module integrates Modbus RTU (via RS485) and Modbus TCP/IP (via Ethernet) protocols, enabling bidirectional communication between field devices and host controllers. It converts incoming power to a regulated 24 VDC output while maintaining 1500 VAC isolation to protect against ground loops and transients. The hardware facilitates deterministic data exchange at 10/100 Mbps, ensuring compatibility with standard industrial networking requirements.
Hardware Identification
The 1TGE102019R4800 is a discrete interface component. There are no configurable hardware sub-suffixes or modular variations provided for this specific part number.
Hardware Specifications
| Parameter | Specification |
| Model | 1TGE102019R4800 |
| Brand | ABB |
| Origin | Sweden |
| Weight | 1.7 kg |
| Shipping Dimensions | 23.8 x 17 x 10.3 cm |
| Operating Temp | -25 deg C to +70 deg C |
| Power Consumption | 24 VDC nominal |
| Communication Ports | RJ45 Ethernet, RS485 |
| Isolation Voltage | 1500 VAC |
Industrial Control Integration
The module is engineered to operate within ABB PLC and DCS environments, where backplane bus communication velocity and I/O density scaling are required to maintain system synchronicity. It supports firmware flash compatibility to allow for updates to communication stacks and protocol handling logic. The integration of deterministic networks ensures that protocol conversion latencies remain within bounds defined for high-speed process control. The module logic includes diagnostic registers accessible via Modbus to facilitate health monitoring of the communication link and internal voltage rails.
Ordering Info
-
1TGE102019R4800 Interfaces Module
-
Static-shielded packaging
-
Technical documentation/manual
-
No external power cables or communication patch cords included
Field Installation Guidelines
-
Mounting: Utilize standard DIN-rail mounting; ensure the unit is snapped firmly onto the rail to maintain structural stability.
-
Grounding: Connect the chassis ground terminal to the main cabinet ground bus using a low-impedance conductor to satisfy surge protection requirements.
-
Wiring: Ensure RS485 A/B lines are terminated with a 120 Ohm resistor at both ends of the physical bus to prevent signal reflections.
-
Separation: Route Ethernet and RS485 cables at least 10 cm away from high-voltage AC power lines to reduce electromagnetic noise coupling.
-
Environment: Install within a clean environment to ensure heat dissipation through the module housing, keeping vents unobstructed.
Frequently Asked Questions
-
Q: Does the module support hot-swap behavior?
-
A: No, the system must be de-energized before removing or installing the module to prevent electrical damage to the communication bus and backplane interface.
-
Q: What is the maximum load capacity for the 24 VDC output?
-
A: The output capacity is limited to the module's rated power budget; check the current draw of connected field devices against the module nameplate specifications.
-
Q: How is the IP address configured?
-
A: Network parameters for the Modbus TCP/IP port are configured via the system software or the onboard diagnostic interface during commissioning.
-
Q: Can RS485 and Ethernet be used simultaneously?
-
A: Yes, the module is designed to bridge data between the Modbus RTU (RS485) and Modbus TCP/IP (Ethernet) networks concurrently.
-
Q: Is the Ethernet port auto-negotiating?
-
A: Yes, the 10/100 Mbps port supports auto-negotiation for duplex and speed settings based on the connected network switch capabilities.
-
Q: Does the module require periodic firmware maintenance?
-
A: Firmware should be updated only if specific protocol compatibility or stability improvements are identified by the system management software.
-
Q: What is the purpose of the 1500 VAC isolation?
-
A: The isolation barrier separates the field-side signaling circuitry from the internal system logic, preventing high-voltage surges from causing equipment damage.
-
Q: Is the RS485 port isolated?
-
A: Yes, the RS485 interface is electrically isolated to prevent ground potential differences between remote field nodes and the control cabinet.
Maxwell PLC is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.