Dimensions: 3.1 cm x 9.0 cm x 6.5 cm
-
Country of origin: Japan
-
Payment: T/T, Western Union
-
Shipping port: Xiamen
Configured for high-density discrete load switching in SYSMAC CJ1 Series platforms, the Omron CJ1W-OD234 (CJ1W-OD234 Transistor Output Unit) provides direct physical/electrical execution.
Technical Identifier Matrix
- Brand: Omron
- Base Model: CJ1W-OD234
- Full Part Number: CJ1W-OD234
- Series Name: SYSMAC CJ1 Series
- Product Type: Transistor Output Unit (32 Points, Sinking)
- Host System: SYSMAC CJ1 Series PLC
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | CJ1W-OD234 |
| Brand | Omron |
| Origin | Japan |
| Weight | 0.07 kg max. |
| Dimensions | 3.1 cm x 9.0 cm x 6.5 cm |
| Shipping Dimensions | 4.0 cm x 11.0 cm x 9.0 cm |
| Operating Temp | 0 deg C ... +55 deg C |
| Power Consumption | 1.1 W (220 mA at 5 VDC from PLC backplane) |
| Rated Voltage | 24 VDC |
| Operating Load Voltage Range | 20.4 to 26.4 VDC |
| Maximum Load Current | 0.5 A/point, 2 A/common, 4 A/Unit |
| Maximum Inrush Current | 4.0 A/point, 10 ms max. |
| Output Configuration | 32 points (Sinking outputs, MIL connector) |
| Number of Circuits | 32 (16 points/common, 2 circuits) |
| ON/OFF Response Time | ON: 15 us max., OFF: 80 us max. |
| Leakage / Residual Voltage | Leakage: 0.1 mA max., Residual: 1.5 V max. |
| External Power Supply | 20.4 to 26.4 VDC, 110 mA min. |
| Insulation Resistance | 20 MOhm min. between external terminals and GR (100 VDC) |
| Dielectric Strength | 1,000 VAC between external terminals and GR for 1 min (leakage 10 mA max.) |
| Internal Protection | None (no internal fuses) |
PLC Controller Processing & Backplane Communication
The CJ1W-OD234 interface operates across the internal backplane bus velocity framework of the SYSMAC CJ1 chassis to deliver rapid bit-state transfers from CPU memory to field actuators. Solid-state output driver arrays execute switching cycles with high-speed response parameters (ON time of 15 us max., OFF time of 80 us max.), supporting high-density I/O density scaling across a dual 16-point common layout. The module isolates internal 5 VDC logic processing from external 24 VDC load loops, maintaining deterministic update execution without inducing voltage noise or backplane processor latency.
Package Contents & Ordering Information
- 1x Omron CJ1W-OD234 Transistor Output Unit
- 1x MIL Connector Cover Shell
Field Installation Guidelines
- Mounting: Seat the unit into the assigned slot on the CJ1 CPU or expansion rack and slide the upper and lower locking levers until locked to the DIN rail.
- Wiring: Terminate field wiring using compatible 40-pin MIL connector wiring harnesses, connecting sinking load return lines to negative common rails.
- Shielding: Route external 24 VDC power and discrete output wiring through grounded metal conduit isolated from high-voltage AC conductors.
- Grounding: Connect the PLC rack functional earth (FE) rail and enclosure ground bus to system earth via a low-impedance copper strap.
Frequently Asked Questions
-
What output switching logic type is utilized by the CJ1W-OD234?
The CJ1W-OD234 utilizes NPN sinking output logic across 32 points organized into 2 isolated circuits of 16 points per common.
-
What are the maximum continuous load current limits for the module?
Current output limits are 0.5 A per point, 2 A per common group, and 4 A maximum for the entire output unit.
-
Does the CJ1W-OD234 contain internal fuse protection for output points?
No, the CJ1W-OD234 does not contain internal fuses; external short-circuit protection devices must be installed on field wiring loops.
-
What is the external power supply requirement for driver operation?
An external supply operating from 20.4 to 26.4 VDC with a minimum current rating of 110 mA is required for output drive circuits.
-
What physical dimensions apply to the CJ1W-OD234 hardware?
The module physical dimensions measure 3.1 cm x 9.0 cm x 6.5 cm with a maximum module weight of 0.07 kg.
-
What are the physical ON and OFF response speeds of the transistor outputs?
The module features high-speed output response times, with an ON delay of 15 us max. and an OFF delay of 80 us max.
-
What dielectric isolation level exists between external terminals and ground?
Dielectric strength is rated at 1,000 VAC for 1 minute between external field terminals and the GR (ground) terminal.
-
What connector style is integrated on the front panel of the unit?
Field wiring interfaces directly to the front panel using a standard multi-point MIL connector interface.
Maxwell PLC is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.