The Omron G3PE-245B-3N, also cataloged as the G3PE 3-Phase Heater Control, operates as a dedicated hardware component for high-frequency solid-state load switching within 3-phase thermal processing loops. Driven by a 12 to 24 VDC control input, the phototriac-isolated power circuit features an integrated zero-cross function to switch 100 to 240 VAC AC loads up to 45 A per phase without contact wear or inductive noise generation.
Part Number Breakdown & Configuration Matrix
- G3PE: Industrial compact solid-state contactor platform for heater control applications
- 245: Rated output load voltage handling up to 240 VAC with a continuous load current rating of 45 A
- B: Built-in zero-cross function designed to minimize inrush current and line surge generation
- 3N: Three-phase output switching configuration with three controlled poles and neutral/line screw terminal landing
Physical & Electrical Specifications
| Parameter | Specification |
|---|---|
| Model | G3PE-245B-3N |
| Brand | Omron |
| Origin | Japan |
| Weight | 3.00 kg |
| Shipping Dimensions | 150 mm x 130 mm x 100 mm |
| Operating Temp | -30 to 80 deg C |
| Power Consumption | Input current: 10 mA max. (at 24 VDC) |
| Rated Input Voltage | 12 to 24 VDC (Operating range: 9.6 to 30 VDC) |
| Rated Load Voltage | 100 to 240 VAC (Operating range: 75 to 264 VAC) |
| Rated Load Current | 45 A per phase (at 40 deg C) |
| Isolation Method | Phototriac isolation |
| Switching Function | Zero cross function equipped |
| Inrush Current Resistivity | 440 A (60 Hz, 1 cycle) |
| Permissible I2t Value | 1260 A2s |
| Applicable Load Capacity | 15.5 kW (at 200 VAC, 3-phase) |
| Terminal Structure | Heavy-duty screw terminals |
PLC Pulse-Width Modulation and Backplane Integration
The unit accepts direct low-power discrete transistor outputs from PLC pulse-width modulation (PWM) modules or temperature controllers without interposition relays. By executing rapid, bounce-free switching cycles, it matches high-speed backplane bus communication velocity Licences across centralized PLC control racks. Deterministic zero-cross firing maintains precise thermal regulation over Profinet / EtherNet/IP networks while preventing backplane noise reflection.
Package Inventory
- 1 x Omron G3PE-245B-3N 3-phase heater control solid-state relay unit
- 1 x Integrated heatsink mounting assembly
- 1 x Technical instruction sheet
Electrical Wiring and Physical Mounting Guidelines
Heatsink Orientation and Clearance
- Mount the unit vertically on a metallic panel surface to ensure unhindered vertical airflow through the integrated heatsink fins.
- Maintain a minimum clearance of 80 mm above and below the heatsink assembly to facilitate natural convection cooling.
Terminal Landing and Surge Protection
- Torque all power screw terminals to specified engineering limits to avoid resistive heating at high current conduction points.
- Install fast-acting semiconductor fuses upstream to match the 1260 A2s I2t limit and protect phototriac output stages from short-circuit faults.
Technical Inquiry Solutions
-
What input voltage limits trigger reliable conduction across the input stage?
The input circuit turns on at 9.6 VDC maximum and fully turns off when the control voltage drops below 1 VDC.
-
How does the zero-cross function suppress electrical noise during power switching?
The phototriac circuit energizes output thyristors only when the AC load voltage passes near zero volts, suppressing surge spikes.
-
Is hot-plugging power leads permitted while the 3-phase load bus is live?
No, disconnecting active 45 A AC load leads under voltage causes severe arc discharge and damages terminal hardware.
-
What maximum peak surge current can the output stage endure during fault conditions?
The power output section withstands a non-repetitive inrush surge current of up to 440 A for 1 full cycle at 60 Hz.
-
Are external interposition relays required between a 24 VDC PLC output card and the input terminals?
No, the input draws a maximum of 10 mA at 24 VDC, allowing direct connection to standard PLC transistor output channels.
-
What total heater load capacity can this controller handle in a 200 VAC 3-phase system?
The unit supports 3-phase resistive heater loads rated up to 15.5 kW when operating at 200 VAC.
-
How does phototriac isolation protect control electronics from line transients?
Optical coupling completely separates low-voltage DC control signals from high-voltage 240 VAC load circuits to block transient spikes.
-
What precautions prevent overheating under continuous 45 A maximum load current?
Ensure vertical mounting on a flat panel, maintain unobstructed ambient airflow, and verify ambient temperatures remain within limits.
Maxwell PLC is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.