NX-ILM400 Omron IO-Link Master Unit NX Series
-
Dimensions: 12 mm x 100 mm x 71 mm
-
Country of origin: Japan
-
Payment: T/T, Western Union
-
Shipping port: Xiamen
The Omron NX-ILM400, also cataloged as the NX-ILM400 IO-Link Master Unit, operates as a dedicated hardware component for serial point-to-point sensor communication and digital process data acquisition within NX I/O Bus architectures.
Functional Configuration & Port Architecture
- NX: Modular I/O platform hardware designator
- ILM: IO-Link Master module classification
- 400: 4-port channel density specification with push-in terminal connectivity
System Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | NX-ILM400 |
| Brand | Omron |
| Origin | Japan |
| Weight | 0.067 kg |
| Shipping Dimensions | 12 mm x 100 mm x 71 mm |
| Operating Temp | 0 deg C to 55 deg C |
| Power Consumption | 1.05 W max. (CPU Unit), 0.80 W max. (Coupler Unit) |
| Number of IO-Link Ports | 4 |
| Refreshing Method | Free-Run refreshing |
| I/O Connection Type | Screwless clamping terminal block (16 terminals) |
| Isolation Method | Photocoupler isolation |
| Insulation Resistance | 20 Mohm min. at 100 VDC (between isolated circuits) |
| Dielectric Strength | 510 VAC for 1 min, leakage current 5 mA max. |
| Current Consumption | 50 mA max. from I/O power supply |
Backplane Synchronization & Fieldbus Execution
The module interfaces directly with the host controller through high-speed internal bus arbitration. Backplane bus communication velocity Licences govern process data exchange across the rack, maintaining deterministic polling cycles for connected smart sensors. Integrated firmware flash compatibility allows seamless parameter download and diagnostic status aggregation across EtherNet/IP and EtherCAT gateway networks without interrupting parallel digital I/O density scaling operations.
Standard Delivery Inventory
- 1 x NX-ILM400 IO-Link Master Unit
- 1 x 16-Pin Screwless Clamping Terminal Connector Block
- 1 x Terminal Wiring Map and Safety Manual
Cabinet Installation & Field Cabling
DIN Rail Mounting Procedure
- Align the rear mounting notch with the standard 35 mm DIN rail and press the module backward until the locking pawl snaps shut.
- Verify minimum clearances of 30 mm above and below the housing to maintain unimpeded thermal convection inside the cabinet.
Wiring & Grounding Guidelines
- Strip field conductors to 9 mm and insert them into the spring-clamp terminals without applying excessive force.
- Route IO-Link point-to-point cables separately from 230 VAC/480 VAC motor supply lines by at least 100 mm to protect weak digital communication pulses from noise coupling.
Frequently Asked Questions
-
What is the isolation mechanism used between field channels and backplane logic?
Photocoupler optical isolation protects internal bus logic from field-side voltage spikes, providing 510 VAC dielectric strength for 1 minute.
-
How is field supply current provided to connected IO-Link devices?
Power distribution is routed through the internal NX bus power rails directly to the 16-pin screwless clamping terminal assembly.
-
Can standard digital sensors be wired to the IO-Link master ports?
Ports can be individually configured via controller software to operate either as IO-Link communications channels or standard digital inputs/outputs.
-
What I/O refreshing mechanism is utilized by the module?
The unit operates via Free-Run refreshing, updating process data asynchronously to the main controller task cycle timebase.
-
Is hot-swapping supported while the NX bus backplane is energized?
Module insertion or removal requires isolating the NX bus power supply to prevent bus communication faults and electrical damage.
-
What terminal block style is utilized for sensor wiring terminations?
The unit features a removable 16-terminal screwless push-in clamping terminal block that accepts solid or ferruled stranded wires.
-
What is the maximum current consumption drawn from the field I/O power bus?
The internal interface circuitry draws up to 50 mA from the shared field I/O power supply line under full operational load.
-
How are module diagnostics and channel status indicated on the hardware?
Front-panel LED indicators display real-time power, bus communication status, individual port operational states, and IO-Link error conditions.
Maxwell PLC is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.