NS10-TV00B-V2 Omron NS Touch-Screen HMI Terminal
-
Dimensions: 28.50 cm x 22.20 cm x 4.80 cm
-
Country of origin: Japan
-
Payment: T/T, Western Union
-
Shipping port: Xiamen
The Omron NS10-TV00B-V2 serves as the primary NS10-V2 Touch-Screen HMI Terminal utilized to execute graphic runtime display and real-time register polling across serial automation platforms. Operating on an external 24 VDC power supply, the unit renders machine parameters on a 10.4-inch VGA TFT matrix and translates operator touch inputs into serial register write commands for linked host PLCs.
Part Number Code & Hardware Variant Structure
- NS10: 10.4-inch display size class within the NS operator interface platform
- TV00: High-resolution VGA TFT display configuration without onboard Ethernet interface
- B: Matte black front panel bezel housing variant
- V2: Version 2 enhanced processing engine and expanded flash memory hardware revision
Physical, Electrical, & Operational Specifications
| Parameter | Specification |
|---|---|
| Model | NS10-TV00B-V2 |
| Brand | Omron |
| Origin | Japan |
| Weight | 2.30 kg max. |
| Shipping Dimensions | 28.50 cm x 22.20 cm x 4.80 cm |
| Operating Temp | 0 to 50 deg C |
| Power Consumption | 25 W max. |
| Supply Voltage | 24 VDC |
| Allowable Voltage Range | 20.4 to 27.6 VDC |
| Display Element | 10.4-inch TFT color LCD |
| Display Resolution | 640 x 480 dots (VGA) |
| Front Panel Protection | IP65 oil-proof equivalent |
| Battery Backup Life | 5 years at 25 deg C |
Hardware Architecture & Firmware Flash Compatibility
The terminal processes vector graphics, trend objects, and alarm logs stored within onboard non-volatile memory. Maintaining firmware flash compatibility between the programming toolchain and internal system flash guarantees deterministic register polling intervals. Direct memory bit manipulation across serial field networks preserves backplane bus communication velocity Licences without imposing transmission overhead on distributed I/O buses.
Supply Scope & Standard Accessories
- 1 x Omron NS10-TV00B-V2 operator interface unit
- 4 x Panel mounting bracket clips
- 1 x Removable 3-pin DC power supply screw terminal block
- 1 x Rear water-resistant panel sealing rubber gasket
- 1 x Standard hardware mounting sheet
Panel Installation & Field Wiring Procedures
Enclosure Mounting and Cutout Alignment
- Prepare the control panel cutout according to standard mechanical enclosure tolerances, removing burrs along the cut edges.
- Fit the sealing gasket onto the rear perimeter rim of the unit before inserting it into the cutout, tightening all four clamp screws evenly.
DC Power Line & Grounding Termination
- Connect 24 VDC power wires to the dedicated 3-pin terminal plug, ensuring correct polarity before applying system voltage.
- Run a dedicated earth conductor from the functional ground terminal lug to the cabinet ground bar to mitigate high-frequency electrical noise.
Technical Frequently Asked Questions
-
What nominal supply voltage is required to power the NS10-TV00B-V2 unit?
The unit operates on a regulated 24 VDC input within an allowable operating voltage range of 20.4 VDC to 27.6 VDC.
-
Does the NS10-TV00B-V2 terminal include a native Ethernet interface port?
No, the TV00 variant is designed for serial communication setups and does not include an onboard RJ45 Ethernet port.
-
What display technology and screen resolution are used on this terminal?
The hardware utilizes a 10.4-inch TFT color LCD matrix featuring a display resolution of 640 x 480 dots (VGA).
-
How does firmware flash compatibility impact project transfer operations?
The system runtime firmware stored in internal flash memory must match the compiler version to ensure tag mappings function correctly.
-
What function is served by the internal lithium battery during power loss?
The backup battery maintains internal real-time clock (RTC) data and preserves retentive alarm logs when 24 VDC power is isolated.
-
What ingress protection rating is provided on the front interface bezel?
The front panel bezel meets IP65 oil-proof equivalent enclosure standards when properly seated with its rubber mounting gasket.
-
Is live insertion or hot-swapping of serial communications cabling permitted?
No, serial port cables must not be connected or removed while power is applied to prevent electrical damage to communication transceivers.
-
What cable routing layout minimizes electrical noise pickup on data lines?
Communication cables must be routed in separate wireways away from high-voltage AC lines, motor leads, and variable frequency drive cabling.
Maxwell PLC is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.