The GE Fanuc IC695LRE001 is a Serial Bus Transmitter Module designed for the PACSystems RX3i programmable logic controller platform. It provides communication between an RX3i Universal Backplane and serial expansion or remote backplanes, converting signal levels for the expansion bus interface.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | IC695LRE001 |
| Brand | GE Fanuc / Emerson |
| Product Type | Serial Bus Transmitter Module |
| Series | PACSystems RX3i |
| Catalog | IC695 |
| Product Weight | Approx. 0.20-0.30 kg |
| Product Dimensions | Approx. 130 × 107 × 32 mm (L × W × H) |
| Current Consumption | 132 mA at 5.0 VDC |
| 3.3 VDC Current Consumption | 0 mA |
| Effective Data Rate | 500 kBytes/s when remote backplanes are included |
| Maximum Cable Length - Expansion | 15 m (50 ft) |
| Maximum Cable Length - Remote | 213 m (700 ft) |
| Communication Interface | Non-isolated differential communications |
| Expansion Backplane Compatibility | IC694 and IC693 series |
| Status Indicators | EXP OK, EXPANSION ACTIVE |
| Mounting | Dedicated expansion connector on right end of Universal Backplane |
| Mounting Fasteners | Two captive screws |
| Recommended Maximum Screw Torque | 0.5 Nm (4.4 in-lb) |
Weight and dimensions are approximate supplier-reported values, not manufacturer-confirmed mechanical specifications. Verify the physical unit before finalizing shipping information.
Product Overview
The IC695LRE001 operates as an expansion interface within the GE Fanuc PACSystems RX3i architecture. It connects the main Universal Backplane to compatible serial expansion and remote backplanes.
The module performs signal-level conversion between the RX3i Universal Backplane and downstream expansion hardware. This allows additional I/O backplanes to communicate with the main controller system.
Unlike standard RX3i I/O modules, the IC695LRE001 installs in the dedicated expansion connector at the right end of the Universal Backplane. It uses two captive screws for mechanical attachment.
Backplane Communication and Expansion Architecture
The IC695LRE001 supports serial expansion through compatible IC694 and IC693 backplane configurations.
Its main engineering functions include:
- Signal-Level Conversion: Converts Universal Backplane signals into the levels required by serial expansion backplanes.
- Remote Rack Communication: Provides the communication interface for downstream remote backplanes.
- Expansion Capacity: Supports an RX3i system configuration with up to seven serial expansion and remote backplanes in total.
- Differential Signaling: Uses non-isolated differential communications.
- Communication Monitoring: Provides two front-panel LEDs for monitoring power and expansion bus activity.
Expansion Cable Requirements
The expansion bus uses dedicated cables to connect the transmitter module with downstream backplanes.
| Cable Model | Description |
|---|---|
| IC693CBL300 | Wye Expansion Cable, 1 m |
| IC693CBL301 | Wye Expansion Cable, 2 m |
| IC693CBL302 | Two-Connector Expansion Cable, 15 m |
| IC693CBL312 | Wye Expansion Cable, 0.15 m |
| IC693CBL313 | Wye Expansion Cable, 8 m |
| IC693ACC307 | Expansion Bus Termination Resistor Pack |
Maximum total cable lengths are 15 m for expansion backplanes and 213 m for remote backplanes. The IC693CBL302 includes a built-in terminating resistor.
Cable selection, routing, and termination must follow the applicable PACSystems RX3i system configuration requirements.
Status Indicators and Diagnostics
The IC695LRE001 incorporates two green LEDs to indicate its operating condition and expansion communication status.
- EXP OK: Illuminates when 5.0 VDC backplane power is applied to the module.
- EXPANSION ACTIVE: Illuminates when the expansion module communicates with connected expansion backplanes.
When EXP OK is off, inspect the backplane power supply and module connection. When EXPANSION ACTIVE is off, check expansion cables, downstream backplane power, and bus termination.
Installation and Electrical Integration
The IC695LRE001 mounts directly into the dedicated expansion connector on the right-hand side of the RX3i Universal Backplane.
Installation considerations:
- Remove backplane power before installing or removing the module.
- Align the transmitter with the dedicated expansion connector.
- Insert the module straight into the connector.
- Secure it using the two captive mounting screws.
- Observe the manufacturer's maximum recommended screw torque of 4.4 in-lb.
- Connect the appropriate expansion cable and verify the bus termination configuration.
- Check both front-panel LEDs after restoring system power.
Important installation restrictions:
- The module does not support hot insertion or removal.
- Expansion cables must not be connected or disconnected while the expansion rack is powered.
- Follow the manufacturer's grounding, shielding, and cable installation requirements.
- Confirm backplane compatibility before integrating the module into an existing RX3i system.
Frequently Asked Questions
- Q: What is the main function of the IC695LRE001?
A: It provides serial expansion bus communication between a PACSystems RX3i Universal Backplane and compatible expansion or remote backplanes.
- Q: Which PLC platform supports this module?
A: The IC695LRE001 is designed for the GE Fanuc PACSystems RX3i programmable logic controller platform.
- Q: Where is the IC695LRE001 installed?
A: It installs in the dedicated expansion connector located at the right end of the RX3i Universal Backplane.
- Q: What is the module's current consumption?
A: It draws 132 mA from the 5.0 VDC backplane supply and 0 mA from the 3.3 VDC supply.
- Q: What is the maximum expansion cable length?
A: The maximum total cable length is 15 m for expansion backplanes and 213 m for remote backplanes.
- Q: Does the IC695LRE001 support hot swapping?
A: No. Backplane power must be removed before installing or removing the Serial Bus Transmitter Module.
- Q: What do the front-panel LEDs indicate?
A: EXP OK indicates backplane 5 VDC power, while EXPANSION ACTIVE indicates communication with expansion backplanes.
- Q: Which expansion cables can be used with this module?
A: Documented cable options include IC693CBL300, IC693CBL301, IC693CBL302, IC693CBL312, and IC693CBL313.
Maxwell PLC is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.