The Omron CJ1W-CTL41-E serves as the primary CJ1W-CTL41 High-speed Counter Unit utilized to execute high-frequency pulse train acquisition and positioning feedback evaluation across SYSMAC CJ-series platforms.
Model Number Structure & Hardware Nomenclature
The Omron CJ1W-CTL41-E fits within the modular SYSMAC CJ-series backplane topology. The alphanumeric nomenclature defines its core hardware capability:
-
CJ1W: Dedicated expansion and Special I/O module system for CJ-series controller racks.
-
CTL: Designation for high-speed counter and complex motion control execution hardware.
-
41: Internal operational specification variant denoting multi-channel pulse input capacity.
-
E: European regional designator indicating compliance with standardized industrial hardware requirements.
-
Slot Allocation: Operates as a Special I/O Unit mapped to dedicated CIO and DM memory registers.
Physical and Electrical Parameters
| Parameter | Specification |
| Model | CJ1W-CTL41-E |
| Brand | Omron |
| Origin | Japan |
| Unit Type | CJ-series Special I/O Unit |
| Internal Current Consumption | 320 mA at 5 VDC (0.32 A) |
| Power Consumption | 1.6 W (via 5 VDC backplane bus) |
| Operating Temperature | 0 to 55 deg C |
| Storage Temperature | -20 to 70 deg C |
| Ambient Humidity | 10% to 90% RH (non-condensing) |
| Unit Dimensions | 31 mm x 90 mm x 65 mm (W x H x D) |
| Unit Weight | Not specified |
| Shipping Weight | 2.0 kg |
| Shipping Dimensions | 150 mm x 120 mm x 75 mm |
| Data Refresh Mapping | CIO-words 2000 to 2959 / DM-words 20000 to 29599 (90 DM-words per unit) |
| Max Units per CPU System | Up to 24 units per basic CJ PLC system (limited by slot capacity) |
Deterministic Network Integration & Backplane Synchronization
High-speed pulse signals are processed locally on the module hardware, bypassing standard CPU scan delays. Communication over the CJ backplane bus updates the assigned CIO I/O Refresh Data Area during each controller cycle. Firmware flash compatibility ensures synchronized parameter transfers from the 90 allocated DM words at CPU startup or unit reset without degrading deterministic loop latency across the automation system.
Scope of Delivery
-
1 x Omron CJ1W-CTL41-E High-speed Counter Unit
-
1 x High-density terminal block assembly
-
1 x Standard installation and wiring reference document
Panel Mounting and Wiring Guidelines
-
Rack Power Isolation: Turn off the main rack power supply prior to inserting or removing the unit from the CJ-series CPU or Expansion Rack slot.
-
Cable Shielding Execution: Connect encoder input lines using shielded twisted-pair cables. Ground the shield at a single point on the enclosure chassis.
-
Signal Line Separation: Maintain a minimum physical distance of 100 mm between high-speed counter input wiring and heavy motor power lines.
-
Terminal Screws Verification: Ensure all terminal screws are torqued down securely to prevent intermittent contact faults during vibration.
Frequently Asked Questions
-
How much memory is reserved in the DM area for module configuration?
The unit utilizes 90 DM-words transferred automatically from the CPU to the module upon power-up or system restart.
-
Can the CJ1W-CTL41-E be hot-swapped while the CJ PLC is powered?
No. The module must be inserted or removed only when the rack power supply is completely switched off.
-
What supply voltage powers the internal logic of the module?
The internal electronics draw operating current directly from the 5 VDC PLC backplane bus at 320 mA.
-
Where can the unit be physically installed in a system?
It can be mounted in any available slot on a CJ-series CPU Rack or CJ-series Expansion Rack.
-
How many CJ1W-CTL41-E units can be installed on a single CJ PLC system?
Up to 24 units can be deployed per basic CJ PLC system, provided backplane power limits are maintained.
-
How are the input address locations determined within the CPU memory?
Input addresses are assigned based on the unit number setting, corresponding to CIO-words 2000 to 2959.
-
What happens if the assigned DM configuration parameters contain invalid values?
The unit flags a initialization configuration error during power-up and halts counting operations until corrected.
-
What type of signal cables should be used for encoder counting inputs?
Use shielded twisted-pair cables to protect high-frequency pulse signals from external electromagnetic interference.
Maxwell PLC is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.