Bently Nevada 350800-01-180-00 3500 Series Hazardous Gas Proximity Sensor
Bently Nevada

Bently Nevada 350800-01-180-00 3500 Series Hazardous Gas Proximity Sensor

SKU: 350800-01-180-00
Categories : All Products
In Stock
  • Dimensions: 20 x 18 x 2 cm
  • Country of origin: USA
  • Payment: T/T, Western Union
  • Shipping port: Xiamen
1 years warranty
Delivery time: 3-7 business days
Free 30 days return

Help

If you have any questions, you are always welcome to contact us. We'll get back to you as soon as possible, withing 24 hours on weekdays.

Customer service

All questions about your order, return and delivery must be sent to our customer service team by e-mail at yourstore@yourdomain.com

Sale & Press

If you are interested in selling our products, need more information about our brand or wish to make a collaboration, please contact us at press@yourdomain.com

Configured for atmospheric monitoring, the Bently Nevada 350800-01-180-00 (350800-01-180-00 Hazardous Gas Sensor) provides direct electrical execution for Lower Explosive Limit (LEL) detection within industrial environments.

Model Designation and Revision

  • 350800: Base Model (Hazardous Gas Sensor)
  • 01: Sensitivity Option (15 mV / % LEL)
  • 180: Version/Revision indicator
  • 00: Default configuration
  • Note: Revised from legacy part number 350800-01-006-00.

Hardware Specifications

Parameter Specification
Model 350800-01-180-00
Brand Bently Nevada
Origin USA
Weight 0.1 kg
Shipping Dimensions 20 x 18 x 2 cm
Operating Temp -40 to +75 deg C
Sensitivity 15 mV / % LEL
Enclosure Rating IP66 / IP67 (Flameproof)
Humidity 0 to 99% RH (non-condensing)

Mechanical Monitoring and Signal Integrity

The 350800 sensor operates as a critical component in environmental safety loops. While primarily distinct from rotor dynamics monitoring, its integration into the Bently Nevada platform ensures that environmental conditions are correlated with machinery performance. The sensor output is calibrated to 15 mV / % LEL, requiring precise signal conditioning to prevent false alarms. Cross-talk suppression and noise rejection are implemented within the sensor head to maintain signal stability in high-EMI environments. Validation of the signal output against specified calibration gases is necessary to ensure the integrity of the safety monitoring chain.

Ordering Information

  • 1 x 350800-01-180-00 Hazardous Gas Sensor

Field Installation Guidelines

  • Flameproof Mounting: The sensor enclosure is flameproof; ensure all thread engagements and cable entries are tightened according to local hazardous area installation standards.
  • Orientation: Install the sensor in a vertical, downward-facing orientation to prevent debris accumulation on the sensing element.
  • Grounding: Secure the metal housing to a verified earth ground point to minimize static buildup and electromagnetic interference.
  • Calibration Access: Provide adequate clearance for routine calibration gas application and sensor maintenance.

Frequently Asked Questions

  • What is the response time of this gas sensor?

    The response time is dependent on gas concentration and airflow; refer to the technical manual for specific T90 response time constants under standard testing conditions.

  • Is the sensor interchangeable with the 350800-01-006-00?

    Yes, this part is the official revision/replacement. Compatibility should be verified against the host system's input range and configuration settings.

  • Does this sensor require external power?

    The sensor operates on a low-voltage DC loop provided by the host monitoring system; ensure loop voltage is within the rated range.

  • How is the sensor calibrated?

    Calibration requires a certified reference gas and an application kit to maintain accuracy; follow the prescribed field calibration intervals.

  • Can it be used in high-dust environments?

    Yes, the IP66/IP67 enclosure rating provides protection against dust ingress, though excessive buildup on the sensor head may affect gas diffusion.

  • Does the sensor output provide a fail-safe signal?

    The sensor loop current or voltage levels are designed to distinguish between normal gas readings, sensor faults, and signal over-range conditions.

  • What is the impact of moisture on the sensor?

    While the sensor is IP-rated, direct liquid water contact on the sensing element can temporarily inhibit gas detection; ensure proper drainage.

  • Can the sensor detect multiple gas types?

    The calibration is specific to target gas types; consult the documentation to confirm the target gas for the 15 mV / % LEL sensitivity setting.

Shipping & Returns

Shipping

  • Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
  • Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
  • Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
  • Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.

Returns

  • 30-Day Window: Request a return within 30 days of receipt for eligible items.
  • Condition: Items must be in their original, factory-sealed condition with all tags.
  • Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
  • Fast Refunds: Approved refunds are processed to your original payment method within 10 days.

Shipping & Returns

Shipping

  • Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
  • Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
  • Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
  • Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.

Returns

  • 30-Day Window: Request a return within 30 days of receipt for eligible items.
  • Condition: Items must be in their original, factory-sealed condition with all tags.
  • Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
  • Fast Refunds: Approved refunds are processed to your original payment method within 10 days.

Warranty

Warranty

  • 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
  • Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
  • Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
  • Peace of Mind: Long-term reliability support for all your mission-critical automation parts.

Warranty

Warranty

  • 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
  • Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
  • Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
  • Peace of Mind: Long-term reliability support for all your mission-critical automation parts.

Secure Payment

Secure Payment

  • Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
  • Local Friendly: RMB transfers are accepted if you have a local agent in China.
  • Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
  • Data Safety: All transactions are processed through encrypted and secure banking channels.


Secure Payment

Secure Payment

  • Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
  • Local Friendly: RMB transfers are accepted if you have a local agent in China.
  • Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
  • Data Safety: All transactions are processed through encrypted and secure banking channels.


You may also like

From our blog

Latest News and Insights

Germany’s High-Value Pivot: Can Advanced Tech Save Its Industrial Base?
Sep 04, 2026
MaxWell
Germany’s High-Value Pivot: Can Advanced Tech Save Its Industrial Base?
Germany’s manufacturing framework is undergoing a structural pivot, balancing macroeconomic stagnation with targeted, high-capital deployments...
Read More
Emerson Unveils DeltaV v16.LTS DCS Architecture
Sep 04, 2026
MaxWell
Emerson Unveils DeltaV v16.LTS DCS Architecture
Modern industrial operations face mounting pressure to modernize their automation infrastructure while controlling lifecycle expenditures...
Read More
Cisco 2026 Report Highlights Industrial AI and Infrastructure Shift
Sep 04, 2026
MaxWell
Cisco 2026 Report Highlights Industrial AI and Infrastructure Shift
Industrial facilities are rapidly evolving into the primary engines of data generation across global enterprise...
Read More
Industrial AI Scaling Depends on OT Data Readiness
Sep 03, 2026
MaxWell
Industrial AI Scaling Depends on OT Data Readiness
Industrial companies have invested heavily in automation, control systems, historians, manufacturing software and enterprise platforms...
Read More
Emerson Secures Automation Deal for Shell Prelude Floating LNG Facility
Sep 03, 2026
Shopify API
Emerson Secures Automation Deal for Shell Prelude Floating LNG Facility
Few engineering achievements capture the imagination quite like Shell Prelude. Moored approximately 475 kilometers off...
Read More
Emerson Selected to Automate BP Shah Deniz Gas Compression Project
Sep 03, 2026
Shopify API
Emerson Selected to Automate BP Shah Deniz Gas Compression Project
In the high-stakes world of offshore and onshore gas production, few projects carry the geopolitical...
Read More
ABB Unveils First Extension Pack for System 800xA with Web-Based Operations
Sep 03, 2026
Shopify API
ABB Unveils First Extension Pack for System 800xA with Web-Based Operations
The industrial automation landscape is shifting rapidly as manufacturers demand greater flexibility from their control...
Read More
Critical Manufacturing to Demonstrate Intelligent MES Platform at SEMICON India 2026
Sep 03, 2026
MaxWell
Critical Manufacturing to Demonstrate Intelligent MES Platform at SEMICON India 2026
Critical Manufacturing is preparing to demonstrate how manufacturers can use MES, industrial connectivity, manufacturing analytics and...
Read More
Automation Can Create a Hidden Single-Point-of-Failure Risk
Sep 03, 2026
MaxWell
Automation Can Create a Hidden Single-Point-of-Failure Risk
As factories become more automated, the biggest operational risk may not always be a failed...
Read More
Water Utilities Face Growing Cybersecurity Pressure as OT Risks Rise
Sep 02, 2026
MaxWell
Water Utilities Face Growing Cybersecurity Pressure as OT Risks Rise
The cybersecurity of water and wastewater infrastructure is drawing renewed attention across the industrial automation...
Read More