Allen-Bradley 440R-S12R2 Guardmaster Safety Relay Module
Allen-Bradley 440R-S12R2 Guardmaster Safety Relay Module
Allen-Bradley 440R-S12R2 Guardmaster Safety Relay Module
Allen-Bradley

Allen-Bradley 440R-S12R2 Guardmaster Safety Relay Module

SKU: 440R-S12R2
Categories : All Products
In Stock
  • Dimensions: 8 x 6 x 1.7 cm
  • Country of origin: USA
  • Payment: T/T, Western Union
  • Shipping port: Xiamen
1 years warranty
Delivery time: 3-7 business days
Free 30 days return

Help

If you have any questions, you are always welcome to contact us. We'll get back to you as soon as possible, withing 24 hours on weekdays.

Customer service

All questions about your order, return and delivery must be sent to our customer service team by e-mail at yourstore@yourdomain.com

Sale & Press

If you are interested in selling our products, need more information about our brand or wish to make a collaboration, please contact us at press@yourdomain.com

The Allen-Bradley 440R-S12R2, also cataloged as the 440R-S12R2 Safety Relay, operates as a dedicated hardware component for emergency stop and interlock monitoring within industrial safety control systems.

Model Classification and Nomenclature

The 440R-S12R2 functions as a single-input safety relay module designed to replace the legacy 440R-J23106 unit. This hardware maintains a specific dual-channel universal input architecture to monitor machine guarding devices and verify safety circuit integrity before enabling control outputs.

Hardware Operational Data

Parameter Specification
Model 440R-S12R2
Brand Allen-Bradley
Origin USA
Weight 0.36 kg
Shipping Dimensions 8 x 6 x 1.7 cm
Power Consumption 2.5 W
Supply Voltage 24 VDC
Safety Output (AC15) 250 V / 1.5 A
Safety Output (DC13) 24 V / 2 A

Allen-Bradley EtherNet/IP and Logic Determinism

The module facilitates integration within deterministic networks, ensuring that safety state transitions are executed within fixed timing windows. As a component of the Guardmaster series, it supports rigid compatibility with standard PLC backplane bus communication velocity and I/O density scaling requirements. The firmware logic is hard-coded to maintain signal consistency, preventing unauthorized modification and ensuring that control responses to input faults remain predictable across distributed industrial control platforms.

Package Contents

  • 1 x 440R-S12R2 Safety Relay unit

  • 1 x Terminal block connector set

  • 1 x Technical documentation sheet

Installation and Shielding Protocols

  • Mounting: Secure the device to a standard 35 mm DIN rail. Maintain a minimum clearance of 5 mm from adjacent heat-generating components to allow for passive thermal dissipation.

  • Grounding: Ensure the system common is bonded to the main protective earth (PE) bus. Use shielded, twisted-pair cabling for all input signal runs exceeding 3 meters to mitigate induced electromagnetic interference.

  • Wiring: Observe local electrical codes for wire gauge selection. Ensure that wire terminations are tightened to the torque specifications provided in the terminal block documentation to prevent contact resistance.

Technical Performance Queries

  • Does this module support hot-swapping?

    No, the 440R-S12R2 does not support hot-swapping. The power supply must be disconnected before the module is removed or installed to prevent electrical arcing or damage to the backplane connectors.

  • What is the primary function of the dual-channel input?

    The dual-channel input monitors two signal paths for synchronization. If the signals do not transition within the specified time window, the module detects a fault and inhibits output activation.

  • Can the auxiliary output be used for safety functions?

    No, the auxiliary output is a solid-state signaling point intended for status monitoring and diagnostic reporting to a PLC, not for controlling hazardous energy.

  • How should the shielding be terminated?

    Connect the cable shield to a single point at the protective earth (PE) bus. Avoid creating ground loops by ensuring the shield is not grounded at both the sensor and the relay end.

  • What happens if the supply voltage drops below 24 VDC?

    Voltage fluctuations below the rated operating threshold may result in intermittent contact state changes or relay chatter. Maintain a stable power source to ensure consistent safety circuit integrity.

  • Is there a specific configuration for the N.C. auxiliary output?

    The N.C. output is fixed to mirror the status of the internal safety contacts. It provides a simple status signal and does not require software mapping within the host controller.

  • What is the impact of DC13 rated inductive loads?

    DC13 ratings define the switching capacity for inductive loads. Exceeding these limits can cause contact pitting and reduce the service life of the internal relay components.

  • Can this unit be used with light curtains?

    Yes, provided the light curtain outputs are compatible with the relay input voltage requirements and meet the necessary safety category for the specific application risk assessment.

Shipping & Returns

Shipping

  • Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
  • Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
  • Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
  • Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.

Returns

  • 30-Day Window: Request a return within 30 days of receipt for eligible items.
  • Condition: Items must be in their original, factory-sealed condition with all tags.
  • Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
  • Fast Refunds: Approved refunds are processed to your original payment method within 10 days.

Shipping & Returns

Shipping

  • Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
  • Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
  • Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
  • Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.

Returns

  • 30-Day Window: Request a return within 30 days of receipt for eligible items.
  • Condition: Items must be in their original, factory-sealed condition with all tags.
  • Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
  • Fast Refunds: Approved refunds are processed to your original payment method within 10 days.

Warranty

Warranty

  • 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
  • Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
  • Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
  • Peace of Mind: Long-term reliability support for all your mission-critical automation parts.

Warranty

Warranty

  • 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
  • Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
  • Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
  • Peace of Mind: Long-term reliability support for all your mission-critical automation parts.

Secure Payment

Secure Payment

  • Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
  • Local Friendly: RMB transfers are accepted if you have a local agent in China.
  • Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
  • Data Safety: All transactions are processed through encrypted and secure banking channels.


Secure Payment

Secure Payment

  • Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
  • Local Friendly: RMB transfers are accepted if you have a local agent in China.
  • Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
  • Data Safety: All transactions are processed through encrypted and secure banking channels.


You may also like

From our blog

Latest News and Insights

Festo Streamlines Pneumatic Motion Control with SDAC-MHS Position Transmitter
Jul 12, 2026
MaxWell
Festo Streamlines Pneumatic Motion Control with SDAC-MHS Position Transmitter
In the rapidly evolving world of industrial automation, the complexity of cabling and hardware integration remains...
Read More
NVIDIA GTC 2026: Accelerating the Shift Toward Adaptive Industrial Robotics
Jul 12, 2026
MaxWell
NVIDIA GTC 2026: Accelerating the Shift Toward Adaptive Industrial Robotics
The industrial landscape is undergoing a fundamental transformation as Physical AI moves out of the laboratory and...
Read More
Triangle Research International Updates FX1616-BA PLC for Enhanced Lifecycle Stability
Jul 12, 2026
MaxWell
Triangle Research International Updates FX1616-BA PLC for Enhanced Lifecycle Stability
The industrial automation landscape often prioritizes functional longevity over radical design shifts, particularly when it...
Read More
NORD Drivesystems Advances Packaging Automation with Smart Decentralized Drives
Jul 11, 2026
MaxWell
NORD Drivesystems Advances Packaging Automation with Smart Decentralized Drives
At this year’s PACK EXPO, NORD Drivesystems showcased a strategic evolution in motion control, highlighting...
Read More
C-Motive Redefines Packaging Efficiency with Electrostatic Motor Technology
Jul 11, 2026
MaxWell
C-Motive Redefines Packaging Efficiency with Electrostatic Motor Technology
As packaging operations demand greater throughput and gentler product handling, traditional electromagnetic motor architectures are...
Read More
PMMI Accelerates Future Workforce Development Through PACK Challenge
Jul 11, 2026
MaxWell
PMMI Accelerates Future Workforce Development Through PACK Challenge
Addressing the critical need for a skilled workforce in industrial automation, PMMI has opened registration for...
Read More
Sanyo Denki Upgrades Industrial Backup with SANUPS N11D Series
Jul 10, 2026
MaxWell
Sanyo Denki Upgrades Industrial Backup with SANUPS N11D Series
Sanyo Denki has introduced the SANUPS N11D standby UPS, specifically engineered to support motor-powered machinery and automation...
Read More
Wieland Electric Enhances Power Density with New WIPOS PSU3 Series
Jul 10, 2026
MaxWell
Wieland Electric Enhances Power Density with New WIPOS PSU3 Series
The demand for reliable, high-density power delivery in modern industrial control panels has reached a critical juncture....
Read More
Bridging Power and Precision: The Evolution of Hybrid Linear Actuation
Jul 10, 2026
MaxWell
Bridging Power and Precision: The Evolution of Hybrid Linear Actuation
The industrial sector is witnessing a transformative shift as engineers move beyond the limitations of...
Read More
Emerson Expands Industrial AI and Wireless Monitoring Capabilities
Jul 09, 2026
MaxWell
Emerson Expands Industrial AI and Wireless Monitoring Capabilities
Emerson has announced a dual-pronged expansion of its automation portfolio, introducing the Synchros wireless monitoring platform for IIoT...
Read More