AI830 3BSE008518R1 ABB Analog Input Modules S800 I/O
-
Dimensions: 4.5 x 10.5 x 12cm
-
Country of origin: Sweden
-
Payment: T/T, Western Union
-
Shipping port: Xiamen
The ABB AI830 3BSE008518R1, also cataloged as the AI830 Analog Input Module, operates as a dedicated hardware component for resistive temperature measurement and signal conditioning within Advant 800xA and Symphony Plus control networks.
Module Configuration
The AI830 provides 8 independent channels configured to interface with resistance-based temperature sensors. The hardware performs internal digitization, linearization, and scaling of raw input signals, providing processed engineering unit values to the central controller backplane. The module architecture is fixed and serves as a direct input terminal for 3-wire resistive sensing elements.
Hardware Specifications
| Parameter | Specification |
| Model | AI830 |
| Brand | ABB |
| Origin | Sweden |
| Weight | 0.24 kg |
| Shipping Dimensions | 4.5 x 10.5 x 12 cm |
| Input Channels | 8 (Independent) |
| Sensor Support | Pt100, Cu10, Ni100, Ni120 |
| Operating Temp | -20 to 70 deg C |
| Power Consumption | 2.5 W |
| Filtering | 50 Hz or 60 Hz selectable |
I/O Density Scaling and Backplane Bus Communication
The AI830 module utilizes the S800 I/O backplane bus to exchange diagnostic and process data with the central controller. The bus communication velocity is optimized for deterministic scanning, ensuring that all 8 channels are refreshed within the module's specified cycle time. High-density mounting in the I/O rack requires management of the module's bus power consumption; users must ensure the cluster's aggregate power draw does not exceed the capacity of the Module Termination Unit (MTU). Firmware flash compatibility ensures the module maintains synchronization with the host controller’s software revision during system commissioning.
Ordering Information
-
Module unit: 1 x AI830 (3BSE008518R1)
-
Packaging: Anti-static factory seal
-
Documentation: Technical reference manual provided in digital format via manufacturer portal
-
Note: MTU (Module Termination Unit) sold separately; necessary for field wiring termination
Field Installation Guidelines
-
Grounding and Shielding:
-
Maintain 3-wire configuration to ensure lead-wire resistance compensation.
-
Use shielded twisted-pair cabling for all field-side connections.
-
Terminate shields at the cabinet-level ground bus to minimize electromagnetic interference.
-
Mounting Requirements:
-
Ensure the MTU is correctly snapped onto the horizontal DIN-rail before seating the AI830 module.
-
Verify locking mechanism engagement to prevent signal disconnection under mechanical vibration.
-
Signal Loop Constraints:
-
Do not exceed the maximum lead-wire resistance specified by the sensor type to maintain 0.1 percent accuracy.
-
Ensure field-side RTD elements are ground-isolated from the process piping or vessel to prevent common-mode noise injection.
Frequently Asked Questions
-
Does the AI830 require external conversion for RTD signals?
No, the module performs integrated signal linearization and scaling internally, transmitting processed values directly to the DCS controller.
-
What is the consequence of exceeding lead-wire resistance limits?
Exceeding resistance limits introduces measurement offsets that cannot be compensated by the 3-wire circuitry, leading to inaccurate temperature reporting.
-
How is the 50 Hz/60 Hz filtering configured?
Filtering is configured through the system software environment at the module object level, matching the site-specific mains frequency to suppress interference.
-
Is the AI830 capable of hot-swapping?
Yes, the S800 I/O architecture supports hot-swapping, allowing module removal and replacement without de-energizing the entire I/O rack or controller.
-
What is the impact of ground-referenced RTD elements?
Ground-referenced sensors create potential ground loops through the module, which may cause erratic signal readings or permanent hardware damage.
-
Can the channels be configured for different sensor types simultaneously?
The AI830 channel configuration is defined within the module parameters; consult the specific I/O hardware library version for channel-specific flexibility.
-
How does the module handle sensor open-circuit detection?
The internal circuitry continuously monitors the loop integrity and reports a status bit to the DCS if the impedance exceeds valid sensor ranges.
-
Is there a specific firmware version requirement for 800xA integration?
Integration requires a compatible hardware library version; users must verify the firmware revision against the system's current hardware support package (HSP).
Maxwell PLC is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.