The ABB 1KHL015545R0001, also cataloged as the O4LE Control Board, operates as a dedicated hardware component for multi-protocol fieldbus communication processing and mixed-signal I/O execution within O4LE network architectures. Configured for direct physical data link interface routing, the board orchestrates field signals via embedded PROFIBUS DP, Modbus RTU, and DeviceNet protocols while managing localized analog inputs and optically isolated digital inputs.
Parametric Specifications
| Parameter | Specification |
| Model | 1KHL015545R0001 O4LE |
| Brand | ABB |
| Origin | USA |
| Weight | 0.5 kg |
| Shipping Dimensions | 18.5 x 6.5 x 12.5 cm |
| Operating Temp | 0 to +55 deg C |
| Storage Temp | -40 to +70 deg C |
| Relative Humidity | 5% to 95% non-condensing |
| Power Consumption | Less than 5 W typical |
| Operating Voltage | 24 VDC (+/- 10%) |
| Isolation Voltage | 1500 VAC |
| Analog Inputs | 2 channels |
| Digital Inputs | 24 VDC, optically isolated |
| Relay Outputs | 250 VAC / 30 VDC, 2 A |
| Communication Protocols | PROFIBUS DP, Modbus RTU, DeviceNet |
| Tariff Code | 8537101190 |
Deterministic Network Architecture and Firmware Execution
The controller relies on a dedicated processing core configured to handle high-velocity network transactions without interfering with baseline control logic tasks. The assembly requires exact firmware flash compatibility verification to maintain simultaneous protocol stacking over fieldbus nodes. This communication layer coordinates variables over the internal backplane bus communication velocity channels, enabling uniform I/O density scaling options across the physical node cluster. By synchronizing digital filter samples with the network master clock, the board guarantees deterministic latency response configurations under peak data line loads.
Packaging Manifest
-
1 x ABB 1KHL015545R0001 O4LE Control Board
-
3 x Terminal Block Headers (Pluggable Type)
-
1 x Terminal Resistance Jumper Pack
On-Site Installation Protocols
-
Static Discharge Mitigation: Field technicians must remain connected to a verified earth ground terminal via an ESD protection strap before unpacking or handling the board.
-
Cabinet Environment Controls: Maintain vertical mounting inside an enclosure with free space parameters matching standard subrack profiles to restrict ambient temperature elevations above +55 deg C.
-
Cable Routing and Shielding: Fieldbus communication lines (PROFIBUS DP, Modbus RTU, and DeviceNet) must utilize specialized shielded twisted-pair cables. Ground the shield at the enclosure bulkhead entry point to block high-frequency electromagnetic interference. Analog input conductors must be segregated from relay output paths.
Logistics and Packaging Controls
-
Fulfillment Cycle: Orders are packaged and ready for dispatch within 2 to 7 days when payment finish processes complete.
-
Shipping Vectors: Consignments are systematically routed worldwide via heavy carriers, specifically DHL, FEDEX, or UPS.
-
Environmental Armoring: Modules are packed within sealed anti-static industrial packaging matrices, reinforced with high-density polyurethane shell inserts to neutralize multidirectional vibration forces during global transit.
Engineering FAQ
Q: Is this control board rated for hot-swap operations under active backplane bus configurations?
A: No. The board does not utilize staggered power trace profiles or dedicated inrush current suppression hardware. Live extraction or insertion while the 24 VDC supply rail is energized can induce backplane voltage spikes, leading to runtime logic corruption or physical damage to adjacent processors.
Q: How is the multi-protocol interface configured on the O4LE board?
A: Protocols (PROFIBUS DP, Modbus RTU, or DeviceNet) are assigned via onboard hardware switches or software parameters that must match the corresponding firmware flash compatibility profile. Only one fieldbus interface can operate as the primary host gateway channel concurrently.
Q: What are the specific electrical limits and protection ratings for the integrated digital input lines?
A: The digital inputs accept a nominal 24 VDC level and are protected by an internal 1500 VAC optical isolation barrier. This decoupling structure blocks transient surge propagation from the external loop into the internal logic core.
Maxwell PLC is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.