1794-ASB Allen-Bradley FLEX I/O Remote I/O Adapter
-
Dimensions: 6.7 x 8.5 x 6.8 cm
-
Country of origin: USA
-
Payment: T/T, Western Union
-
Shipping port: Xiamen
The Allen-Bradley 1794-ASB serves as the primary 1794-ASB Remote I/O Adaptor utilized to execute remote I/O data processing across FLEX I/O platforms. The device operates as a hardware gateway that interfaces an external Universal Remote I/O network link with the local cluster backplane. It manages serial data block transfers, converting master controller commands into discrete logic signals for up to 8 attached I/O sub-modules without introducing communication cycle latency into the hardware system.
Functional Matrix Allocation
The product designation sequence maps specific engineering configurations. The "1794" code dictates structural and interface alignment with standard distributed terminal blocks. The "ASB" suffix identifies the internal architecture as a remote I/O link processor utilizing a multi-pin logic bus structure. This adapter layout handles synchronous physical word configurations over 3-wire shielded media configurations, routing signals across standard modular backplane slots.
Physical and Electrical Parameters
| Parameter | Specification |
|---|---|
| Model | 1794-ASB |
| Brand | Allen-Bradley |
| Origin | USA |
| Weight | 0.18 kg |
| Shipping Dimensions | 6.7x8.5x6.8cm |
| Operating Temp | 0 to 55 deg C |
| Power Consumption | Supported by external 24 VDC voltage supply loop |
| Input Voltage Range | 19.2 to 31.2 VDC |
| Network Protocol | Universal Remote I/O (RIO) |
| Backplane Capacity | Maximum 8 I/O module slots |
| Enclosure Protection | IP20 open-style architecture |
| Assembly Mounting | Symmetrical DIN rail tracking alignment |
Deterministic Backplane Communications
This interface component regulates system data integrity by enforcing rigid I/O density scaling profiles across the internal connections. The device supports local backplane bus communication velocity Licences controls to prevent collision bottlenecks when high-density configurations are requested. Digital signal mapping tracks direct memory image updates, verifying that sub-module arrays operate within specific firmware flash compatibility matrices while matching hardware baud rates across the network trunk line.
Shipment Packing Array
- 1 x 1794-ASB remote network adapter block
- 1 x physical terminal connection document
Wiring and Shielding Directives
-
DIN Rail Retention Interlock
Angle the top slot of the industrial housing over the upper flange of the DIN rail, then drive the lower enclosure edge downward until the locking claw secures.
-
Network Media Signal Termination
Secure the blue, clear, and bare shield wires of the remote I/O cable into the designated 3-pin termination socket, using identical color codes across all active nodes.
-
Terminal Module Serial Coupling
Align the side interlocking slots of the adapter housing with the initial terminal base plate, pushing horizontally until the internal backplane pins interface completely.
-
Power Conductor Feed Installation
Connect the positive and negative leads from an external 24 VDC power supply to the input terminals, checking that torque limits match structural specifications.
Frequently Asked Questions
-
What specific engineering constraints limit the hot-swapping capacity of this communication interface block?
The module cannot be detached while the backplane power loop is active. Removing the unit breaks the network loop, halting processing for all connected modules.
-
How are the network baud rate parameters calibrated on this specific remote interface hardware?
Baud rate settings are defined mechanically using the DIP switch bank situated on the enclosure surface before the hardware is fastened to the mounting track.
-
What failure signature indicates a communication disconnect between the adapter and the master processor?
A network link failure causes the adapter status indicator to flash red, forcing the localized discrete output circuits to shift into their programmed safe states.
-
Does the 0.18 kg weight specification include the field wiring terminal plate or adjacent modules?
No. The weight represents the standalone network adapter core module, excluding the terminal bases, field wires, or separate network terminator resistors.
-
What procedure resolves an address configuration conflict between duplicate nodes on the same network run?
The system loop power must be disconnected, the rotary or DIP switches adjusted to an unassigned node address, and the 24 VDC supply re-applied to reset the block.
-
How does the hardware structure maintain data synchronization when analog and digital modules are mixed?
The internal micro-sequencer executes synchronous backplane bus scans, organizing data blocks into a single image frame to manage mixed I/O configurations.
-
Is an external terminating resistor required at the network interface connections of this module?
Yes. If the adapter serves as the final physical node on the Universal Remote I/O line, an external resistor must be secured across the signaling terminals.
-
Can this unit function within high-humidity environments without a secondary secondary enclosure box?
No. The open-style IP20 housing lacks moisture seals, requiring a protective industrial enclosure to prevent condensation from causing electrical degradation.
Maxwell PLC is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.