1701/10 Bently Nevada 1701 Series FieldMonitor Power Supply Module
-
Dimensions: 12.5 x 2.1 x 10.5 cm
-
Country of origin: USA
-
Payment: T/T, Western Union
-
Shipping port: Xiamen
The Bently Nevada 1701/10 serves as the primary 1701 FieldMonitor Power Supply Module utilized to execute technical power conditioning and over-voltage protection across 1701 Series platforms. The hardware accepts an unstable DC input voltage range and converts it into regulated internal power rails required to drive the monitoring node electronics and associated sensor arrays.
Internal Matrix Identification
-
1701: Core product line platform designator for the industrial FieldMonitor distributed processing hardware.
-
10: Specific functional hardware modification defining the internal switching DC-to-DC power supply module configuration.
Operating Parameters
| Parameter | Specification |
| Model | 1701/10 |
| Brand | Bently Nevada |
| Origin | USA |
| Module Type | FieldMonitor Power Supply Modules |
| Input Voltage Range | +18 V to +36 V DC (24 VDC nominal) |
| Nominal Inrush Current | 30 Amp pk maximum |
| Circuit Protection | Over-voltage tracking and internal safety fusing |
| Safety Fuse Rating | 250 V, 3 Amp, Slow-Blow (SB) |
| Galvanic Isolation Voltage | 850 Vdc from primary circuit to chassis for 1 minute |
| Power Consumption | Determined by active I/O load, bounded by internal thermal dissipation profiles |
| Operating Temperature | -20 to +70 deg C |
| Storage Temperature | -40 to +85 deg C |
| Shipping Dimensions | 12.5 cm x 2.1 cm x 10.5 cm |
| Weight | 0.36 kg |
Mechanical Monitoring & TSI Integration
The power supply architecture provides clean, low-ripple DC potentials necessary to maintain exact eddy-current probe scaling characteristics within adjacent proximity channels. Stable source rails protect the node from voltage dips that could corrupt gap voltage validation procedures configured for standard -10 VDC targets. By decoupling input power line transients from internal measurement electronics, the unit preserves the resolution required to monitor dynamic rotor dynamics and ensures cross-talk suppression metrics remain stable across multi-channel backplanes.
Hardware Packaging
-
1 1701/10 FieldMonitor Power Supply Module
-
1 Spare 3 Amp Slow-Blow Replacement Fuse
Electrical and Field Integration
Mechanical Seating and Enclosure Locking
-
Align the backplane edge connector pins with the dedicated power slot inside the FieldMonitor node frame assembly.
-
Slide the module evenly into the guide rails until the front plate meets the frame, then torque the retention fasteners to secure electrical continuity.
Input Power Connections and Ground Paths
-
Route the +24 VDC supply lines through dedicated terminal blocks using copper wire rated for the peak inrush envelope.
-
Connect the main structural grounding lug from the terminal block directly to the central enclosure chassis bus to ensure correct isolation barriers are maintained.
Frequently Asked Questions
-
Is live hot-swap replacement permitted for this power block while the monitor node is operating?
No, the power supply must be powered down before extraction to prevent electrical arcing across the backplane bus pins.
-
What failure symptoms occur if the primary input line voltage drops below the +18 V DC limit?
The module initiates an under-voltage shutdown protocol, disabling the internal power rails to protect downstream processor components.
-
How does the hardware manage the high 30 Amp peak nominal inrush current during initial startup?
Internal current-limiting thermistors or soft-start circuits damp the initial power spike to safeguard external distribution breakers.
-
Can the internal safety fuse be replaced in the field by plant maintenance teams?
Yes, the module houses an accessible 250 V, 3 Amp slow-blow fuse that can be serviced once the hardware is disconnected.
-
Does this module require dedicated external cooling fans inside sealed field cabinets?
The hardware operates via natural convection cooling across its designated -20 to +70 deg C window when standard spacing rules are maintained.
-
What isolation barrier is maintained between the incoming power lines and the chassis earth?
The internal design provides galvanic isolation tested up to 850 Vdc from the primary inputs to the chassis frame for 1 minute.
-
What happens to the transmitter output loops if the internal over-voltage circuit trips?
The system clamps the surge voltage internally or blows the primary fuse, shifting the hardware to a safe unpowered state.
-
Does this specific power card option supply direct loop current to external proximity probes?
It energizes the internal backplane, which subsequently allows the system input cards to supply the required potentials to paired Proximitors.
Maxwell PLC is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.