Omron CP1W-TS102 Temperature Sensor Unit CP1W Series
-
Dimensions: 5.0 cm x 8.6 cm x 9.0 cm
-
Country of origin: Japan
-
Payment: T/T, Western Union
-
Shipping port: Xiamen
Configured for platinum resistance thermometer input processing in Omron CP1-series PLC platforms, the Omron CP1W-TS102 (CP1W-TS102 Temperature Sensor Unit) provides direct physical/electrical execution.
Technical Identifier Matrix
- Series Prefix (CP1W): Expansion I/O unit for CP1H, CP1L, and CP1E PLC systems
- Function Code (TS): Temperature sensor input expansion module
- Sensor Type Code (1): RTD / Platinum resistance thermometer input configuration
- Input Density Code (02): 4-channel RTD input processing capacity (Pt100 / JPt100)
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | CP1W-TS102 |
| Brand | Omron |
| Origin | Japan |
| Weight | 0.250 kg |
| Dimensions | 5.0 cm x 8.6 cm x 9.0 cm |
| Shipping Dimensions | 8.0 cm x 11.0 cm x 11.5 cm |
| Operating Temp | 0 to 55 deg C |
| Power Consumption | 5 VDC: 54 mA max. / 24 VDC: 73 mA max. |
| Input Channels | 4 inputs |
| Supported Temperature Sensors | Platinum resistance thermometer (Pt100 or JPt100, switchable; uniform across all channels) |
| Allocated Input Words | 4 words (1 word per input channel) |
| Conversion Time | 250 ms for 2 or 4 input points |
| Converted Temperature Data | 16-bit binary data (4-digit hexadecimal format) |
| Isolation | Photocouplers between all temperature input signals and internal backplane logic |
PLC Determinism and Backplane Bus Velocity
The CP1W-TS102 expansion interface transfers 16-bit binary RTD temperature values directly across the internal CP-series backplane bus during the PLC cyclic scan I/O refresh window. High-speed backplane velocity ensures 4 allocated input words update deterministically without introducing CPU processing jitter or expanding cyclic execution times.
The modular expansion bus permits scaled I/O density integration by chaining multiple CP1W modules side-by-side using the built-in flat ribbon bus connector. Integrated photocoupler isolation between temperature input channels and CPU logic prevents ground loops and blocks common-mode noise propagation across expansion racks.
Package Contents & Ordering Information
- 1x Omron CP1W-TS102 Temperature Sensor Unit
- 1x Integrated Expansion Bus Cable
- 1x Removable Terminal Block Assembly
- 1x CP1W Hardware Installation Manual
Field Installation Guidelines
- DIN-Rail Mounting: Mount the unit on a 35 mm DIN rail (PFP-50N/PFP-100N). Ensure side locking mechanisms lock securely to prevent lateral vibration displacement.
- Backplane Connection: Plug the integrated flat ribbon cable directly into the expansion bus connector of the preceding CPU or expansion module.
- RTD Sensor Wiring: Wire 3-wire Pt100/JPt100 sensors ensuring equal wire resistance across conductors A, B, and b to maintain measurement accuracy.
- Grounding and Shielding: Terminate RTD signal cable shielding at a single point using a 360-deg braid grounding clamp attached to the protective earth terminal.
- Terminal Tightening: Fasten terminal block screws to a torque rating of 0.5 N-m to prevent contact degradation.
Frequently Asked Questions
-
What sensor types are supported by the CP1W-TS102?
The module supports Pt100 and JPt100 platinum resistance thermometers. All 4 channels must be set to the same sensor type.
-
How many input channels and CIO words does the module allocate?
The module features 4 RTD input channels and allocates 4 input words in the PLC memory map.
-
What is the analog-to-digital conversion time for all 4 channels?
The conversion time is 250 ms total for 2 or 4 active input channels.
-
What format is used to store converted temperature values in PLC memory?
Temperature values are formatted as 16-bit binary data expressed in 4-digit hexadecimal.
-
What current consumption does the module draw from the expansion bus?
The module draws a maximum of 54 mA at 5 VDC and 73 mA at 24 VDC from the backplane.
-
What isolation mechanisms protect internal CPU logic from field interference?
Photocouplers provide galvanic isolation between individual temperature input signals and internal CPU backplane logic.
-
Can different sensor types be mixed across channels on a single module?
No, while the unit is switchable between Pt100 and JPt100, the same sensor type must be used across all 4 inputs.
-
Is hot-swapping permitted for this expansion module during PLC operation?
No, removing or inserting expansion units while the base controller is energized is strictly prohibited.
Maxwell PLC is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.