1794-TB3S Allen-Bradley FLEX I/O Series Terminal Base Unit
-
Dimensions: 10.2 cm x 7.6 cm x 10.2 cm
-
Country of origin: USA
-
Payment: T/T, Western Union
-
Shipping port: Xiamen
Configured for signal or control execution in industrial systems, the Allen-Bradley 1794-TB3S (1794-TB3S Terminal Base Unit) provides direct electrical or data interface functions. The hardware serves as the supporting connection block for modular distributed I/O modules, establishing proper terminal landing paths for field sensors and actuators while passing data along the passive internal communication bus.
Hardware Designation Breakdown
- 1794: Platform prefix denoting the modular FLEX I/O hardware system architecture.
- -TB3S: Suffix configuration specifying a 3-wire spring-clamp termination layout block.
- /A: Revision track tracking the current internal structural layout standard.
Technical Parameters
| Parameter | Specification |
|---|---|
| Model | 1794-TB3S |
| Brand | Allen-Bradley |
| Origin | USA |
| Weight | 0.2 kg |
| Shipping Dimensions | 10.2 x 7.6 x 10.2 cm |
| Operating Temperature | 0 to +55 deg C |
| Power Consumption | Passive bus interface (draw limited by the mounted module) |
| Voltage Rating | 125 VAC/DC maximum |
| Current Rating | 10 A maximum |
| Frequency | 50/60 Hz |
| I/O Terminals | 16 spring-clamp points |
| Common Terminals | 18 spring-clamp points |
| Voltage Terminals | 18 spring-clamp points (+V) |
| Enclosure Type | IP20 open style |
| Mounting Base | 35 mm symmetric DIN rail |
Bus Communication and Wiring Layout
The terminal base manages internal backplane bus communication velocity across adjacent active processing hardware, preventing local register drop-outs over EtherNet/IP deterministic networks. The integrated spring-clamp termination geometry expands I/O density scaling by offering 16 individual signal terminations, 18 common links, and 18 positive voltage source connection slots in a single open-style footprint. This internal routing layout eliminates external distribution blocks, ensuring direct field-side termination paths. Mechanical alignment tolerances guarantee long-term hardware configuration stability and complete firmware compatibility when matching analog or digital logic components are attached to the block.
Box Packing Elements
- 1 x 1794-TB3S FLEX I/O Spring-Clamp Terminal Base
- 1 x FlexBus sliding interface connector piece
Field Installation Guidelines
Wiring Constraints
- Depress the cage clamp mechanism fully using a standard slot screwdriver tool before feeding in stripped conductors.
- Strip field wire outer insulation layers to 10 mm to ensure proper spring compression engagement inside the slot.
- Do not combine solid and stranded copper lines within a single spring-clamp landing port.
Grounding Rules
- Snap the module housing firmly onto a clean, unpainted steel 35 mm DIN rail to establish a dedicated chassis ground path.
- Verify the spring-loaded grounding clip on the back of the base makes continuous bare-metal contact with the mounting track.
Shielding Requirements
- Terminate analog field loop shields at an isolated instrument ground bus located outside the local termination block.
- Do not connect shield drain wires to the internal common or voltage terminals of the base assembly.
Backplane Insertion Rules
- Slide the left-side FlexBus connector completely into the preceding unit before locking the terminal base down.
- Ensure all mating pins are aligned straight before pressing an active module onto the terminal base top seat.
Environmental Limitations
- Mount the IP20 open-style block within a NEMA or IP-rated enclosure to prevent particulate accumulation on contact surfaces.
- Maintain a 25 mm air clearance perimeter around the base unit to permit natural convective cooling under high current loads.
Technical Support FAQ
-
Q: What is the hot-swap behavior when replacing an active I/O module positioned on this terminal base?
A: The base unit sustains continuous backplane bus communication across adjacent nodes, permitting live hot-swap replacement of the upper module without dropping system network nodes.
-
Q: What is the backplane load contribution of the terminal base when added to a FlexBus segment?
A: The hardware consists of passive conductor traces and spring contacts, drawing 0 mA of electrical current from the control backplane logic supply.
-
Q: What redundancy switching delay is added by this component during a processor switchover?
A: As a passive structural interconnection device with no internal registers or memory, it introduces a 0 ms delay during system redundancy switching operations.
-
Q: Are there firmware compatibility limitations when using this base revision with legacy series modules?
A: No, the unit is entirely hardware-based and analog, which eliminates dependencies on firmware flash levels, software builds, or electronic microcode versions.
-
Q: How does the internal signal isolation mechanism separate field loops from the logical backplane?
A: The base provides passive copper trace paths; all channel-to-channel or galvanic backplane isolation operations are handled inside the active plugged module.
-
Q: What specific field wiring constraints govern the selection of wires for these spring-clamp blocks?
A: Use solid or stranded copper wire sized between 0.34 mm2 (22 AWG) and 2.1 mm2 (14 AWG) rated for the target loop operating voltage.
-
Q: Can this base handle simultaneous combinations of AC and DC loop voltages across separate channels?
A: The base insulation holds up to 125 VAC/DC, but the actual voltage configuration must match the specific limits of the single module installed.
-
Q: What causes potential intermittent connection issues inside a spring-clamp terminal slot?
A: Intermittent contact typically stems from under-stripping wire insulation or leaving wire strands bent outside the internal compression cage during tool execution.
Maxwell PLC is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.