1794-TB3G Allen-Bradley Terminal Bases FLEX I/O Series
-
Dimensions: 9.6 x 9.6 x 5.8 cm
-
Country of origin: USA
-
Payment: T/T, Western Union
-
Shipping port: Xiamen
The Allen-Bradley 1794-TB3G, also cataloged as the 1794-TB3G Terminal Bases, operates as a dedicated hardware component for signal processing or control execution within industrial automation architectures. This specific termination variant establishes the physical wire-to-bus connections necessary for modular distributed input and output systems, facilitating clear electrical paths between external field instruments and central monitoring hardware.
Suffix & Model Matrix
- 1794: Core catalog prefix designating the modular industrial FLEX I/O platform.
- -TB3G: Suffix code indicating a grounded terminal base layout containing 36 input/output termination clamps, 2 common terminals, and 2 positive voltage source connections.
- /A: Manufacturing series designation specifying the primary internal hardware architectural revision layer.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | 1794-TB3G |
| Brand | Allen-Bradley |
| Origin | USA |
| Weight | 0.2 kg |
| Dimensions | 9.6 x 9.6 x 5.8 cm |
| Operating Temperature | 0 to +55 deg C |
| Power Consumption | Passive distribution mechanism (actual loop draw managed by plugged module) |
| Total I/O Terminals | 36 screw-clamp points |
| Common Terminals | 2 points |
| Voltage Terminals | 2 points (+V) |
| Grounding Configuration | Integrated chassis grounding terminal tracks |
| Enclosure Protection Rating | IP20 open style |
| Mounting Format | Direct 35 mm DIN rail installation |
| Spare Part Numbers | 1794-TB3G/A, 96269675 |
| Tariff Code | 8537101190 |
Backplane Communication and I/O Density
The structural interface of the base layout sustains local backplane communication across adjacent processing modules. By handling physical termination constraints within an open-style footprint, the framework supports a high I/O density configuration across deterministic local area architectures. System configurations operating over Profinet or EtherNet/IP networks utilize the copper connections inside the base to pass binary and analog register data packages without experiencing signal attenuation or communication bus speed degradation. Furthermore, strict physical tolerance manufacturing guarantees long-term hardware and firmware compatibility parameters whenever matching modular industrial processing devices are hot-swapped or upgraded during normal system lifecycle maintenance.
Ordering Information
- 1 x 1794-TB3G FLEX I/O Grounded Terminal Base Assembly
- 1 x Factory-installed FlexBus slide-to-lock interconnection block
- 1 x Technical installation parameters summary sheet
Installation Guidelines
Grounding Rules
- Mount the unit directly onto a zinc-plated, clear-chromate steel 35 mm DIN rail to establish a low-impedance path to frame ground.
- Avoid using non-conductive, painted, or heavily oxidized mounting rails that could prevent the grounding foot from making clean electrical contact.
Wiring Constraints
- Strip conductor insulation layers to exactly 7 mm before feeding the wire into the open terminal throat.
- Tighten all active screw clamps to a target torque specification of 0.8 N.m to prevent loose compression connections.
- Keep signal wiring separation zones clear from multi-phase electrical motor circuits or arc-producing inductive elements.
Shielding Requirements
- Terminate field instrument shield drains directly at an isolated external system grounding bar located within the central control cubicle.
- Do not layer or connect field instrument shields to the common or voltage rails located on the base block.
Backplane Insertion Rules
- Verify the adjacent left-hand slot FlexBus connector interface is pushed in fully before snapping the terminal base down.
- Do not force module insertion pins onto the base socket alignment tracks; inspect for bent components before complete mating.
Environmental Limitations
- Ensure that ambient ambient temperatures inside the cabinet structure stay within the standard 0 to +55 deg C operational limits.
- Maintain clear space margins around all ventilation pathways to allow heat to rise naturally from active terminal blocks.
Frequently Asked Questions
-
Q: What is the hot-swap behavior when replacing a faulty I/O module sitting on this terminal base?
A: The terminal base maintains uninterrupted backplane communication continuity along the remaining FlexBus path, letting you hot-swap the attached active module under live system power.
-
Q: Does this base unit place any measurable backplane load on the system power supply?
A: No, the hardware consists of passive conductor links, copper pathways, and terminal screws, meaning it draws 0 mA of local current from the backplane bus.
-
Q: What redundancy switching delay is caused by this terminal base component during a processor changeover?
A: The unit features no active electronic components, microprocessors, or registers, meaning it introduces a 0 ms switching delay during redundancy system swap sequences.
-
Q: Are there internal firmware compatibility checks needed when swapping an older module onto a new revision base?
A: No, the component is completely analog and structural, which renders it independent of system firmware flash levels, software builds, or module program revisions.
-
Q: How does the internal signal isolation mechanism operate within the terminal block layout?
A: The hardware provides passive physical channels; all galvanic, optical, or channel-to-channel signal isolation operations are handled entirely by the active plugged I/O module.
-
Q: What specific field wiring constraints govern the selection of conductors for these screw clamps?
A: Use solid or stranded copper wire sized between 0.34 mm2 (22 AWG) and 2.1 mm2 (14 AWG) rated for the specific loop voltage levels.
-
Q: What causes an unexpected ground loop fault across the 2 common terminals?
A: Ground loops typically happen if external field device commons are tied to separate earth points while simultaneously landing on the base terminal rail.
-
Q: Can this open-style IP20 housing be installed directly inside an outdoor washdown environment?
A: No, it is rated IP20 open style, requiring installation inside an appropriately certified NEMA or IP-rated protective industrial cabinet to prevent dust and water intrusion.
Maxwell PLC is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.