{"product_id":"v680-hs51-omron-v680-series-cylindrical-antenna","title":"V680-HS51 Omron V680 Series Cylindrical Antenna","description":"\u003cp\u003eThe \u003cstrong\u003eOmron V680-HS51\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eV680-HS51\u003c\/strong\u003e Cylindrical Antenna, operates as a dedicated hardware component for high-frequency electromagnetic field RFID read\/write transactions within industrial tracking networks.\u003c\/p\u003e\n\u003ch3\u003eNomenclature \u0026amp; Component Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eV680\u003c\/strong\u003e: High-Frequency Industrial RFID Hardware Platform\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHS\u003c\/strong\u003e: High-Sensitivity Inductive Antenna Head Component\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e51\u003c\/strong\u003e: Compact Threaded Cylindrical Housing Form Factor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Cable\u003c\/strong\u003e: Integrated 2 m High-Flex Connection Cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications Summary\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eV680-HS51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003eM12 x 35 mm (Housing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to 60 deg C (with no icing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via RFID controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e20 MOhm min. (at 500 VDC) between cable terminals and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e1,000 m\/s2 in X, Y, and Z directions 3 times each (18 times total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e10 to 2,000 Hz, 1.5-mm double amplitude at 150 m\/s2 acceleration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Connectivity \u0026amp; Firmware Flash Protocols\u003c\/h3\u003e\n\u003cp\u003eThe inductive reader transducer couples non-contact data packets directly into host processing units via deterministic fieldbus structures. System initialization executes automated firmware flash compatibility handshakes to match coil carrier frequencies with controller firmware revs, eliminating cycle jitter and packet drops on active control loops.\u003c\/p\u003e\n\u003ch3\u003ePackage Inventory\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron V680-HS51 Cylindrical RFID Antenna Unit (2 m Cable Attached)\u003c\/li\u003e\n\u003cli\u003e2 x Brass Retaining Lock Nuts\u003c\/li\u003e\n\u003cli\u003e1 x Installation Sheet and Grounding Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Mounting \u0026amp; Shielding Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThread the M12 metallic barrel through a rigid mounting plate and secure it firmly using both retaining lock nuts.\u003c\/li\u003e\n\u003cli\u003eEnsure surround metallic structures remain outside the specified clear radius to prevent inductive detuning of the RF field.\u003c\/li\u003e\n\u003cli\u003eRoute the integrated 2 m antenna cable through separate low-voltage wireways isolated from high-power AC motor drives.\u003c\/li\u003e\n\u003cli\u003eGround the mating RFID controller ground terminal to a common cabinet earth rail using stranded copper conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat cable length is permanently attached to the antenna housing?\u003c\/p\u003e\n\u003cp\u003eThe unit comes equipped with an integrated 2 m connection cable for direct coupling to the RFID amplifier unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat mechanical shock limits can the housing endure during operation?\u003c\/p\u003e\n\u003cp\u003eThe solid enclosure handles severe shock impacts up to 1,000 m\/s2 applied 3 times each across X, Y, and Z axes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the antenna handle severe industrial machine vibration?\u003c\/p\u003e\n\u003cp\u003eIt withstands 10 to 2,000 Hz variable sweep vibration with 1.5-mm double amplitude at 150 m\/s2 acceleration limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat insulation resistance metric is verified across terminal blocks?\u003c\/p\u003e\n\u003cp\u003eTesting guarantees an insulation resistance of 20 MOhm minimum at 500 VDC between internal cable leads and outer casing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does firmware flash compatibility affect antenna processing?\u003c\/p\u003e\n\u003cp\u003eThe connected controller validates firmware flash protocol revisions at startup to ensure aligned inductive scan timing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat thermal operating limits apply to active field installations?\u003c\/p\u003e\n\u003cp\u003eThe unit operates reliably across ambient temperatures from -10 deg C to 60 deg C provided no surface ice formation occurs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs external power wiring required directly at the antenna head?\u003c\/p\u003e\n\u003cp\u003eNo, operational power and high-frequency communication signals pass through the 2 m cable directly from the controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat shielding measures prevent RF carrier wave interference?\u003c\/p\u003e\n\u003cp\u003eMaintain separation from adjacent inductive sensors and earth the controller chassis shield terminal to a low-impedance bar.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306660348077,"sku":"V680-HS51","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/v680-hs51_3.jpg?v=1790660023","url":"https:\/\/www.maxwellplc.com\/ru\/products\/v680-hs51-omron-v680-series-cylindrical-antenna","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}