{"product_id":"tsxdey32d2k-schneider-electric-modicon-premium-discrete-input-module","title":"TSXDEY32D2K Schneider Electric Modicon Premium Discrete Input Module","description":"\u003cp\u003eConfigured for discrete signal execution in Modicon Premium automation platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSchneider Electric TSXDEY32D2K\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eTSXDEY32D2K\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDiscrete Input Module) provides direct physical electrical execution for 32 current sink isolated inputs.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe TSXDEY32D2K designates a standard-format module utilizing 24 VDC positive logic. The suffix identifies the specific I\/O density and hardware interface type, facilitating integration into rack-based backplane configurations consistent with the Modicon Premium series architecture.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTSXDEY32D2K\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRefer to product labeling\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.5 cm x 18.0 cm x 26.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e135 mA at 5 VDC \/ 160 mA at 24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDiscrete Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 (Current Sink, Type 1)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6300 Ohm at state 1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePLC Deterministic Control and Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe Modicon Premium platform utilizes a high-speed backplane bus to ensure consistent I\/O scan timing. The TSXDEY32D2K module is optimized for deterministic input acquisition, supporting I\/O density scaling across the rack. Firmware flash compatibility and bus communication velocity are managed via the host processor, ensuring that the 7 ms response time requirement is maintained for integrated proximity sensor logic.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x TSXDEY32D2K Discrete input module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x User documentation set\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: Field wiring requires an HE-10 connector interface kit, which must be ordered according to the specific cable length and shielding requirements of the application.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Install the module in a standard Modicon Premium rack slot. Verify the mechanical alignment of the backplane connector before engaging the locking mechanism.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnections: Utilize the HE-10 connector for signal wiring. Maintain consistent routing paths to minimize noise coupling, as the module features IP20 protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Bond the rack chassis to a stable earth ground point to ensure the effectiveness of the dielectric strength (1500 VAC) and electrostatic immunity profiles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironment: Adhere to specified relative humidity (10% to 95%) and pollution degree 2 limits to prevent degradation of internal components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the TSXDEY32D2K module hot-swappable?\u003c\/p\u003e\n\u003cp\u003eA: No, the module does not support hot-swapping. Ensure the rack power is disconnected before installing or removing the unit to prevent backplane damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What input type does this module support?\u003c\/p\u003e\n\u003cp\u003eA: The module supports 32 current sink inputs conforming to the EN\/IEC 61131-2 Type 1 standard.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the required sensor power supply range?\u003c\/p\u003e\n\u003cp\u003eA: The connected sensors must be supplied with a voltage ranging between 19 VDC and 30 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How is the module connected to field devices?\u003c\/p\u003e\n\u003cp\u003eA: The module utilizes a standard HE-10 connector for all 32 discrete input channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the maximum operating altitude?\u003c\/p\u003e\n\u003cp\u003eA: The hardware is rated for reliable operation up to an altitude of 2000 m.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What happens if input voltage falls below 5 VDC?\u003c\/p\u003e\n\u003cp\u003eA: The module registers a State 0 status, as 5 VDC is the guaranteed threshold for the OFF state.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the module compatible with both 2-wire and 3-wire sensors?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the input circuitry is compatible with standard 2-wire and 3-wire proximity sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the isolation resistance specification?\u003c\/p\u003e\n\u003cp\u003eA: The isolation resistance is specified as less than 10 MOhm at 500 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46472826978477,"sku":"TSXDEY32D2K","price":150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/TSXDEY32D2K_13.jpg?v=1782807214","url":"https:\/\/www.maxwellplc.com\/ru\/products\/tsxdey32d2k-schneider-electric-modicon-premium-discrete-input-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}