{"product_id":"tb5610-2eth-1sap111300r0278-abb-ac500-terminal-base","title":"TB5610-2ETH 1SAP111300R0278 ABB AC500 Terminal base","description":"\u003cp\u003eConfigured for high-speed network routing and slot interconnection within AC500 V3 platforms, the \u003cstrong\u003eABB TB5610-2ETH 1SAP111300R0278\u003c\/strong\u003e (\u003cstrong\u003eTB5610-2ETH\u003c\/strong\u003e Terminal base) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eArchitectural Suffix \u0026amp; Hardware Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTB5610-2ETH\u003c\/strong\u003e: Core designation denoting AC500 V3 terminal base architecture with dual Ethernet routing support.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1SAP111300R0278\u003c\/strong\u003e: Official manufacturing order code assigned for component stocking and exact replacement tracking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC500 V3 Compatibility\u003c\/strong\u003e: Tailored interface matrix designed to support modern third-generation processor and communication modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Interface Slot\u003c\/strong\u003e: Integrates 2 Ethernet ports, 1 serial interface, and 1 CAN communication slot (TB5610-2ETH configuration).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTB5610-2ETH (1SAP111300R0278)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e13.5 x 12.5 x 3.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTerminal Base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eAC500 V3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Wiring Terminals\u003c\/td\u003e\n\u003ctd\u003e24 x spring-clamp terminals (0.08 to 2.5 mm squared)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified (Passive bus distribution base)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003eNot specified (Standard industrial limits apply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Execution \u0026amp; Bus Integration\u003c\/h3\u003e\n\u003cp\u003eThe terminal base ensures high-speed backplane bus communication velocity Licences across connected processor and I\/O expansion tiers. Integrated support for Profinet and EtherNet\/IP deterministic networks enables seamless packet routing, while firmware flash compatibility on mated CPUs allows instant parameter synchronization without signal distortion.\u003c\/p\u003e\n\u003ch3\u003eDelivery Package Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB TB5610-2ETH (1SAP111300R0278) Terminal Base\u003c\/li\u003e\n\u003cli\u003e1 x Anti-Static Protective Enclosure\u003c\/li\u003e\n\u003cli\u003e1 x Terminal Wiring Reference Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Mounting \u0026amp; Wiring Instructions\u003c\/h3\u003e\n\u003ch4\u003eDIN-Rail Installation Procedures\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSnap the modular base securely onto a standard 35 mm DIN rail inside an IP54 rated control panel enclosure.\u003c\/li\u003e\n\u003cli\u003eMaintain minimum clearance clearances around top and bottom cable channels to allow unhindered thermal air convection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSpring-Clamp Field Termination Guidelines\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eStrip field wires to a length of 8 mm and insert them directly into the 24 spring-clamp terminals rated for 0.08 to 2.5 mm squared conductors.\u003c\/li\u003e\n\u003cli\u003eEnsure incoming 24 VDC power and communication cable shields are properly bonded to the panel ground bar to suppress electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIs the TB5610-2ETH base module hot-swappable under power?\u003c\/p\u003e\n\u003cp\u003eNo, power must be completely isolated from the 24 VDC supply before inserting or extracting mounted CPU or communication modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat voltage range is supported on the incoming power distribution lines?\u003c\/p\u003e\n\u003cp\u003eThe terminal base distributes standard 24 VDC control power across the backplane bus for connected processor units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many communication modules can be plugged into this specific base?\u003c\/p\u003e\n\u003cp\u003eThe hardware layout provides a dedicated single slot for one communication module alongside dual onboard Ethernet ports.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat conductor cross-section size fits the spring-clamp terminals?\u003c\/p\u003e\n\u003cp\u003eThe 24 spring-clamp field wiring points accommodate solid and stranded wire dimensions ranging from 0.08 to 2.5 mm squared.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat level of electrical isolation protects the communication channels?\u003c\/p\u003e\n\u003cp\u003eThe internal circuit architecture provides 1500 VAC isolation to safeguard against transient line surges and ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the extreme ambient operating temperature limits?\u003c\/p\u003e\n\u003cp\u003eThe base module functions continuously within an ambient temperature range spanning from -25 deg C to +60 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat relative humidity conditions can the unit withstand?\u003c\/p\u003e\n\u003cp\u003eThe system operates reliably in non-condensing relative humidity environments between 5% and 95% RH.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat protocol interfaces are available directly on the terminal base?\u003c\/p\u003e\n\u003cp\u003eThe unit features 2 Ethernet interfaces, 1 serial interface, and 1 integrated CAN interface channel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021079629997,"sku":"TB5610-2ETH 1SAP111300R0278","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1sap111300r0278_1.jpg?v=1791903334","url":"https:\/\/www.maxwellplc.com\/ru\/products\/tb5610-2eth-1sap111300r0278-abb-ac500-terminal-base","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}