{"product_id":"schneider-electric-tsxaey1600-16-channel-analog-input-module","title":"Schneider Electric TSXAEY1600 16-Channel Analog Input Module","description":"\u003cp\u003eThe Schneider Electric TSXAEY1600 is a 16-channel high-level analog input module designed for Modicon Premium PLC systems. It measures voltage and current signals from compatible industrial instruments and converts them into 12-bit digital values. Multiple input ranges allow the module to accommodate different transmitter and process measurement requirements. It is suitable for industrial applications requiring centralized analog signal acquisition.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 high-level analog input channels\u003c\/li\u003e\n\u003cli\u003eSupports voltage and current measurement\u003c\/li\u003e\n\u003cli\u003e12-bit analog-to-digital conversion\u003c\/li\u003e\n\u003cli\u003eCurrent ranges: 0–20 mA and 4–20 mA\u003c\/li\u003e\n\u003cli\u003eVoltage ranges: ±10 V, 0–10 V, 0–5 V, and 1–5 V\u003c\/li\u003e\n\u003cli\u003eNominal read cycle time of 51 ms\u003c\/li\u003e\n\u003cli\u003eFast read cycle based on the number of active channels\u003c\/li\u003e\n\u003cli\u003eMeasurement error as low as 0.1% of full scale at 25 °C for voltage ranges\u003c\/li\u003e\n\u003cli\u003eTwo 25-pin SUB-D connectors\u003c\/li\u003e\n\u003cli\u003eDesigned for Schneider Electric Modicon Premium PLC systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSXAEY1600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eModicon Premium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Level\u003c\/td\u003e\n\u003ctd\u003eHigh Level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Analog Inputs\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Type\u003c\/td\u003e\n\u003ctd\u003eVoltage and Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input Ranges\u003c\/td\u003e\n\u003ctd\u003e0–20 mA, 4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Ranges\u003c\/td\u003e\n\u003ctd\u003e±10 V, 0–10 V, 0–5 V, 1–5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog-to-Digital Conversion\u003c\/td\u003e\n\u003ctd\u003e12 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Read Cycle Time\u003c\/td\u003e\n\u003ctd\u003e51 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFast Read Cycle Time\u003c\/td\u003e\n\u003ctd\u003e3 ms + 3 ms × number of channels used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Measurement Error at 25 °C\u003c\/td\u003e\n\u003ctd\u003e0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Measurement Error at 25 °C\u003c\/td\u003e\n\u003ctd\u003e0.16% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Measurement Error at 0–60 °C\u003c\/td\u003e\n\u003ctd\u003e0.13% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Measurement Error at 0–60 °C\u003c\/td\u003e\n\u003ctd\u003e0.32% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Between Channels and Bus\u003c\/td\u003e\n\u003ctd\u003e1000 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Between Channels and Ground\u003c\/td\u003e\n\u003ctd\u003e1000 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Overvoltage Protection\u003c\/td\u003e\n\u003ctd\u003e-15 to +15 V at State 0; -30 to +30 V at State 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvercurrent Protection\u003c\/td\u003e\n\u003ctd\u003e-30 to +30 mA at State 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003e2 × 25-pin SUB-D connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e270 mA at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Format\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0–60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e10–95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Humidity\u003c\/td\u003e\n\u003ctd\u003e5–95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0–2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Treatment\u003c\/td\u003e\n\u003ctd\u003eTC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Dimensions\u003c\/td\u003e\n\u003ctd\u003e5.50 × 18.00 × 26.00 cm (third-party reference; verify module orientation and measurement basis)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e0.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003e16-Channel Analog Signal Acquisition\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe TSXAEY1600 provides 16 analog input channels for collecting process measurements from compatible field instruments. It supports both voltage and current signal types, allowing different transmitter outputs to be integrated into one PLC module.\u003c\/p\u003e\n\u003cp\u003eSupported current ranges include 0–20 mA and 4–20 mA. Voltage measurement ranges include ±10 V, 0–10 V, 0–5 V, and 1–5 V.\u003c\/p\u003e\n\u003cp\u003eThe module uses 12-bit analog-to-digital conversion to transform incoming signals into digital values for the Modicon Premium controller.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMultirange Voltage and Current Inputs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe multirange design allows the TSXAEY1600 to accommodate a variety of industrial measurement signals. This flexibility is useful when integrating pressure, flow, level, and other process transmitters.\u003c\/p\u003e\n\u003cp\u003eThe selected input range must correspond to the connected instrument's output signal. Correct range configuration helps maintain measurement accuracy and prevents incorrect process readings.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMeasurement Accuracy and Conversion Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe nominal read cycle time is 51 ms. For applications requiring faster acquisition, the module supports a fast read cycle calculated as 3 ms plus 3 ms multiplied by the number of channels used.\u003c\/p\u003e\n\u003cp\u003eAt 25 °C, the specified measurement error is 0.1% of full scale for voltage ranges and 0.16% for current ranges. Across the 0–60 °C operating range, the corresponding values are 0.13% and 0.32%.\u003c\/p\u003e\n\u003cp\u003eActual measurement performance depends on the selected input range and operating conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Isolation and Input Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe TSXAEY1600 provides 1000 Vrms isolation between channels and the bus, as well as between channels and ground.\u003c\/p\u003e\n\u003cp\u003eThe module also includes input overvoltage and overcurrent protection. These functions help protect the analog input circuitry against specified electrical fault conditions.\u003c\/p\u003e\n\u003cp\u003eCorrect field wiring, signal grounding, and transmitter selection remain essential for reliable operation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Connection and Installation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe TSXAEY1600 uses two 25-pin SUB-D connectors for its analog input connections.\u003c\/p\u003e\n\u003cp\u003eThe connector pin assignments distinguish positive voltage inputs, positive current inputs, and common signal connections. The COM terminals are internally linked within the module.\u003c\/p\u003e\n\u003cp\u003eBefore installation, verify the connector pinout and ensure that the field wiring matches the selected voltage or current input range.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eModicon Premium System Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe TSXAEY1600 belongs to Schneider Electric's Modicon Premium automation platform. It is designed for compatible Premium PLC rack configurations.\u003c\/p\u003e\n\u003cp\u003eThe module can be used in applications requiring 16-channel analog signal acquisition. For replacement projects, verify the rack configuration, module position, connector arrangement, and PLC application configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Industrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe TSXAEY1600 is suitable for industrial installations requiring multiple analog measurement channels.\u003c\/p\u003e\n\u003cp\u003eTypical applications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOil and gas processing facilities\u003c\/li\u003e\n\u003cli\u003eChemical and petrochemical plants\u003c\/li\u003e\n\u003cli\u003ePower generation systems\u003c\/li\u003e\n\u003cli\u003eWater and wastewater treatment\u003c\/li\u003e\n\u003cli\u003eIndustrial manufacturing lines\u003c\/li\u003e\n\u003cli\u003ePressure and flow measurement\u003c\/li\u003e\n\u003cli\u003eLevel monitoring systems\u003c\/li\u003e\n\u003cli\u003eProcess control and instrumentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eReplacement and Compatibility Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSchneider Electric has discontinued the TSXAEY1600. The manufacturer identifies BMXAMI0810 from the Modicon X80 family as a recommended replacement.\u003c\/p\u003e\n\u003cp\u003eHowever, the BMXAMI0810 provides eight analog input channels, compared with the TSXAEY1600's 16 channels. It is therefore not a direct functional equivalent in channel capacity.\u003c\/p\u003e\n\u003cp\u003eBefore planning a replacement, review the required channel count, input signal types, rack architecture, wiring, and PLC configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. What is the Schneider Electric TSXAEY1600?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is a 16-channel multirange analog input module designed for Schneider Electric Modicon Premium PLC systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. How many analog input channels does the TSXAEY1600 provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module provides 16 high-level analog input channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Which current signals does the TSXAEY1600 support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt supports 0–20 mA and 4–20 mA current input ranges.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. Which voltage ranges are available?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module supports ±10 V, 0–10 V, 0–5 V, and 1–5 V input ranges.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. What is the analog-to-digital resolution?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe TSXAEY1600 uses 12-bit analog-to-digital conversion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e6. Which electrical connectors does this module use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt uses two 25-pin SUB-D connectors for analog signal connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e7. Is the TSXAEY1600 discontinued?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Schneider Electric lists the product as discontinued. Its published end-of-service date on the Singapore product page is December 31, 2026.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e8. What is the recommended replacement for TSXAEY1600?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSchneider Electric identifies BMXAMI0810 from the Modicon X80 family. However, it has eight input channels rather than 16, so a system-level assessment is necessary before replacement.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":68377282478253,"sku":"TSXAEY1600","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/tsxaey1600-1.jpg?v=1795141461","url":"https:\/\/www.maxwellplc.com\/ru\/products\/schneider-electric-tsxaey1600-16-channel-analog-input-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}