{"product_id":"schneider-electric-tm5sdo12t-discrete-output-module-modicon-tm5","title":"Schneider Electric TM5SDO12T Discrete Output Module Modicon TM5","description":"\u003cp\u003eConfigured for discrete signal output in Modicon TM5 and PacDrive LMC controller environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSchneider Electric TM5SDO12T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eTM5SDO12T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDiscrete Output Module) provides direct physical electrical execution of 12 source-logic switching commands.\u003c\/p\u003e\n\u003ch3\u003eModel Identification and Series Context\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTM5SDO12T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econstitutes a 12-channel transistor output module utilizing 1-wire connection architecture. It is designed specifically for integration within the Modicon TM5 distributed I\/O slice system, compatible with PacDrive LMC motion controllers, M258, and LMC058 logic controller platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTM5SDO12T\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRefer to product labeling\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.025 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.00 cm x 5.40 cm x 10.50 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 to 55 deg C (horizontal) \/ -10 to 50 deg C (vertical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e52 mA at 5 VDC \/ 48 mA at 24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Logic\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSource\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (20.4 to 28.8 VDC range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 A per channel \/ 6 A per common\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResponse Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;= 300 us (state 0 to 1 \/ 1 to 0)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Controller Integration\u003c\/h3\u003e\n\u003cp\u003eThe TM5SDO12T supports I\/O density scaling within the TM5 bus structure, enabling granular configuration of distributed control architectures. Deterministic timing is maintained via the backplane bus, ensuring synchronization with PacDrive LMC motion cycles. Firmware management and parameterization are performed through the SoMachine or EcoStruxure Machine Expert software environments, which govern the bus communication cycle and module diagnostic polling.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x TM5SDO12T Discrete output module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Technical documentation sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: Terminal blocks are required for field wiring and are typically provided as part of the bus base assembly or sold separately depending on the specific system configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Procedures\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Snap the module onto the TM5 system DIN rail. Ensure proper alignment of the bus connector to maintain electrical continuity across the slice assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCabling: Utilize single-wire configurations as specified. Ensure wire gauges comply with terminal block capacity to maintain the IP20 integrity and connection security.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Establish common potential references for the 24 VDC I\/O power segment. Use the integrated power distribution features of the bus bases to minimize external wiring loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtection: Implement external inductive load protection (flyback diodes) on all inductive outputs to prevent back-EMF damage to the internal transistors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does this module support hot-swapping during active system operation?\u003c\/p\u003e\n\u003cp\u003eA: No, the TM5SDO12T does not support hot-swapping. Disconnect the system power and the external I\/O power supply segment before attempting to remove or replace the module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I connect 2-wire loads directly to the outputs?\u003c\/p\u003e\n\u003cp\u003eA: Yes, though it is recommended to use a TM5SPDG12F Common Distribution module to facilitate proper wiring of the 0 VDC return path for 2-wire devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the purpose of the 6 A common current rating?\u003c\/p\u003e\n\u003cp\u003eA: This is the maximum permissible aggregate current for the entire output common circuit; it must not be exceeded even if individual channel currents are within the 0.5 A limit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the module protected against short circuits?\u003c\/p\u003e\n\u003cp\u003eA: The module does not feature individual channel short-circuit protection. External fuses or circuit breakers should be installed in the power distribution path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What does the red LED on the module indicate?\u003c\/p\u003e\n\u003cp\u003eA: The red LED indicates a fault or power supply error within the module's localized power segment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this module operate in a vertical mounting position?\u003c\/p\u003e\n\u003cp\u003eA: Yes, but the operating temperature range is derated to a maximum of 50 deg C, compared to the 55 deg C limit for horizontal installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the peak output current capability?\u003c\/p\u003e\n\u003cp\u003eA: The module supports a peak output current of 12 A, strictly subject to the specified duration and thermal constraints of the output stage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the module provide galvanic isolation between channels?\u003c\/p\u003e\n\u003cp\u003eA: No, the outputs are internally referenced to the common; galvanic isolation is provided between the output stages and the internal backplane logic bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46463380226221,"sku":"TM5SDO12T","price":59.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/TM5SDO12T_14.jpg?v=1782799570","url":"https:\/\/www.maxwellplc.com\/ru\/products\/schneider-electric-tm5sdo12t-discrete-output-module-modicon-tm5","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}