{"product_id":"sa910s-3kde175131l9100-abb-power-supply-advant-ocs-800xa","title":"SA910S 3KDE175131L9100 ABB Power Supply Advant OCS\/800xA","description":"\u003cp\u003eConfigured for primary AC-to-DC voltage conversion in Advant OCS\/800xA systems, the \u003cstrong\u003eABB SA910S 3KDE175131L9100\u003c\/strong\u003e (\u003cstrong\u003eSA910S\u003c\/strong\u003e Power Supply) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eDesignator Mapping \u0026amp; Technical Structure\u003c\/h3\u003e\n\u003cp\u003eThe hardware designator scheme specifies functional parameters across system subracks:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSA910S\u003c\/strong\u003e: Main product designator for the regulated system power supply card.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3KDE175131L9100\u003c\/strong\u003e: Manufacturing part reference for subrack slot integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePS24-Ex\u003c\/strong\u003e: Spare part designation cross-referenced to the 3KDE175131L9100 assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTariff Code\u003c\/strong\u003e: 8537101190 for low-voltage industrial control power supplies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \u0026amp; Environmental Data\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSA910S 3KDE175131L9100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSWEDEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e85 to 264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Frequency\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current Limit\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 0.95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified (Input\/Output converter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Weight\u003c\/td\u003e\n\u003ctd\u003e1.14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e6.6 cm x 12 cm x 15.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 % (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Bus \u0026amp; Hardware Integration\u003c\/h3\u003e\n\u003cp\u003eThe module supplies regulated 24 VDC bus power across the local rack assembly to maintain uninterrupted CPU and I\/O communication execution. High-density I\/O density scaling and real-time data transfers across Profinet or EtherNet\/IP deterministic networks rely on stable supply rails, avoiding communication drops. Onboard firmware flash compatibility and system rack logic supervision maintain steady backplane bus communication velocity during system power transients.\u003c\/p\u003e\n\u003ch3\u003ePackage Delivery Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB SA910S 3KDE175131L9100 Power Supply Unit\u003c\/li\u003e\n\u003cli\u003e1 x Anti-static protective enclosure bag\u003c\/li\u003e\n\u003cli\u003e1 x Installation guide and pinout reference manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSubrack Mounting \u0026amp; Wiring Precautions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Line Disconnection\u003c\/strong\u003e: Isolate external AC mains voltage before inserting or removing the power supply module from the rack slot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Connection\u003c\/strong\u003e: Ensure the panel enclosure earth stud connects directly to protective earth ground to maintain noise suppression.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConvection Clearance\u003c\/strong\u003e: Maintain clear vertical airflow paths above and below the module heat sink to facilitate thermal dissipation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Screws\u003c\/strong\u003e: Torqued screw terminals on AC supply inputs to prevent high-resistance connections and local thermal buildup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat range of AC input voltage does the SA910S 3KDE175131L9100 accommodate?\u003c\/p\u003e\n\u003cp\u003eThe module accepts standard universal AC input sources ranging from 85 to 264 VAC at frequencies of 47 to 63 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat output voltage is generated by the SA910S module for subrack loads?\u003c\/p\u003e\n\u003cp\u003eThe unit provides a regulated 24 VDC bus output to power adjacent controller cards and I\/O subrack modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the peak inrush current limit during initial AC power-up?\u003c\/p\u003e\n\u003cp\u003eThe integrated power supply input circuitry limits the cold-start inrush current to \u0026lt;= 20 A under full line loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the SA910S module be hot-swapped while the rack backplane is energized?\u003c\/p\u003e\n\u003cp\u003eNo. System power feeds must be isolated before pulling or inserting the power supply module to prevent internal arcing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the module maintain high electrical efficiency on AC mains?\u003c\/p\u003e\n\u003cp\u003eThe unit incorporates active power factor correction circuitry yielding a power factor parameter of \u0026gt;= 0.95.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat spare part model code corresponds to the 3KDE175131L9100 hardware?\u003c\/p\u003e\n\u003cp\u003eThe manufacturing spare part cross-reference identifier for this power unit is PS24-Ex 3KDE175131L9100.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat ambient temperature limits apply to operating hardware installations?\u003c\/p\u003e\n\u003cp\u003eThe unit operates within industrial thermal limits specified from -25 to +70 deg C under non-condensing humidity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the power supply require external forced-air cooling fans?\u003c\/p\u003e\n\u003cp\u003eConvection cooling operates effectively provided standard vertical clearance dimensions around the module are maintained.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021148672173,"sku":"3KDE175131L9100","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb_sa910s_3kde175131l9100_2.jpg?v=1788357909","url":"https:\/\/www.maxwellplc.com\/ru\/products\/sa910s-3kde175131l9100-abb-power-supply-advant-ocs-800xa","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}