{"product_id":"rdco-01c-64606948-abb-acs800-ddcs-communication-option-module","title":"RDCO-01C 64606948 ABB ACS800 DDCS Communication Option Module","description":"\u003cp data-path-to-node=\"4\"\u003eThe \u003cb data-path-to-node=\"4\" data-index-in-node=\"4\"\u003eABB RDCO-01C 64606948\u003c\/b\u003e, also cataloged as the \u003cb data-path-to-node=\"4\" data-index-in-node=\"49\"\u003eRDCO-01C\u003c\/b\u003e DDCS Communication Option Module, operates as a dedicated hardware component for high-speed optical data transfer and drive controller interfacing within ABB ACS800 frequency converter platforms.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"5\"\u003eHardware Variant \u0026amp; Connector Interface\u003c\/h3\u003e\n\u003cp data-path-to-node=\"6\"\u003eThe RDCO-01C module mounts directly into designated drive expansion slots using internal header pins and retaining fasteners. Primary identification criteria comprise:\u003c\/p\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003eModule Hardware Designation: RDCO-01C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003eFactory Code Designation: 64606948\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003eInterface Type: 20-pin internal board connector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003eCommunication Architecture: Distributed Drives Communication System (DDCS)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"8\"\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"9\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,1,1,0\"\u003eRDCO-01C 64606948\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,2,1,0\"\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,3,0,0\"\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,3,1,0\"\u003eSWEDEN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,4,0,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,4,1,0\"\u003e0.05 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,5,0,0\"\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,5,1,0\"\u003e9.5 x 3.6 x 3.3 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,6,0,0\"\u003eSupply Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,6,1,0\"\u003e24 VDC (+\/- 10%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,7,0,0\"\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,7,1,0\"\u003e\u0026lt; 5 W typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,8,0,0\"\u003eOperating Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,8,1,0\"\u003e200 mA @ 24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,9,0,0\"\u003eCommunication Speed\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,9,1,0\"\u003eUp to 12 Mbps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,10,0,0\"\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,10,1,0\"\u003e0 to +55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,11,0,0\"\u003eStorage Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,11,1,0\"\u003e-40 to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,12,0,0\"\u003eRelative Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,12,1,0\"\u003e5% to 95% non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,13,0,0\"\u003eTariff Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,13,1,0\"\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,14,0,0\"\u003eDispatch Location\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"9,14,1,0\"\u003eXiamen, China\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"10\"\u003eAutomation Platform Bus \u0026amp; Deterministic Processing\u003c\/h3\u003e\n\u003cp data-path-to-node=\"11\"\u003eThe RDCO-01C option board utilizes optical DDCS channels (CH0 to CH3) to maintain backplane bus communication velocity Licences and isolate signal processing from ambient electrical noise. Integrated board logic ensures strict firmware flash compatibility across AC 800PEC and ACS800 control units, supporting deterministic networks execution and rapid parameter exchange across Profinet \/ EtherNet\/IP topologies.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"12\"\u003eDelivery Package Checklist\u003c\/h3\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e1 x ABB RDCO-01C 64606948 DDCS Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e2 x M3 x 8 Fixing Screws\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e1 x Anti-Static Protective Packaging Sleeve\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"14\"\u003eAssembly \u0026amp; Optical Wiring Guidelines\u003c\/h3\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,0,0\"\u003ePower Disconnection\u003c\/p\u003e\n\u003cul data-path-to-node=\"15,0,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,0,1,0,0\"\u003eTurn off all main power feeds and external 24 VDC auxiliary lines prior to inserting or removing the option card.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,1,0\"\u003eBoard Insertion \u0026amp; Mechanical Fastening\u003c\/p\u003e\n\u003cul data-path-to-node=\"15,1,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,1,1,0,0\"\u003eSeat the module into the slot labeled \"DDCS\" to engage the 20-pin header, securing it with plastic clips and two M3 x 8 screws to complete the GND earth path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,2,0\"\u003eOptical Fiber Handling\u003c\/p\u003e\n\u003cul data-path-to-node=\"15,2,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,2,1,0,0\"\u003eObserve transmitter (V_T) and receiver (V_R) color codes during cross-connection. Do not bend plastic optical fiber cables tighter than a 35 mm minimum radius.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,3,0\"\u003eCable Maintenance\u003c\/p\u003e\n\u003cul data-path-to-node=\"15,3,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,3,1,0,0\"\u003eClean optical fiber cable endpoints with lint-free wipes and isopropyl alcohol before insertion to maintain signal light intensity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"16\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul data-path-to-node=\"17\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,0,0\"\u003eQ: What auxiliary supply voltage and operating current are required for the RDCO-01C module?\u003c\/p\u003e\n\u003cp data-path-to-node=\"17,0,1\"\u003eA: The card requires a 24 VDC supply (+\/- 10%) and draws an operating current of 200 mA under nominal load conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,1,0\"\u003eQ: What maximum data transfer rate is achieved across the optical DDCS channels?\u003c\/p\u003e\n\u003cp data-path-to-node=\"17,1,1\"\u003eA: The module supports optical data communication transmission speeds operating up to 12 Mbps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,2,0\"\u003eQ: Is hot-swapping supported when installing or removing this communication module?\u003c\/p\u003e\n\u003cp data-path-to-node=\"17,2,1\"\u003eA: No, auxiliary drive power must be fully isolated before inserting or unseating the 20-pin backplane connector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,3,0\"\u003eQ: How is electrical frame grounding established during mechanical mounting?\u003c\/p\u003e\n\u003cp data-path-to-node=\"17,3,1\"\u003eA: Frame earthing and GND signal interconnects are established directly via two M3 x 8 mounting screws connected to the drive control board.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,4,0\"\u003eQ: What is the minimum allowable bending radius for plastic fiber optic cables?\u003c\/p\u003e\n\u003cp data-path-to-node=\"17,4,1\"\u003eA: Fiber optic lines connected to the optical ports must maintain a bend radius greater than 35 mm to avoid signal attenuation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,5,0\"\u003eQ: How does firmware flash compatibility affect drive communication setup?\u003c\/p\u003e\n\u003cp data-path-to-node=\"17,5,1\"\u003eA: Alignment between control board firmware and module registers guarantees valid telegram structure mapping and predictable timing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,6,0\"\u003eQ: What are the physical transport package dimensions and total item weight?\u003c\/p\u003e\n\u003cp data-path-to-node=\"17,6,1\"\u003eA: The module weighs 0.05 kg with boxed shipping dimensions measuring 9.5 cm in length, 3.6 cm in width, and 3.3 cm in height.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"17,7,0\"\u003eQ: What optical port color coding rules apply to transmitter and receiver channels?\u003c\/p\u003e\n\u003cp data-path-to-node=\"17,7,1\"\u003eA: Transmitters (V_T) are marked with blue or grey color codes, whereas receivers (V_R) feature black connector housings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021077270701,"sku":"RDCO-01C","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/rdco-01c_1.jpg?v=1791901217","url":"https:\/\/www.maxwellplc.com\/ru\/products\/rdco-01c-64606948-abb-acs800-ddcs-communication-option-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}