{"product_id":"pr6426-010-100-con021-915-200-emerson-epro-proximity-sensor-system","title":"PR6426-010-100 CON021\/915-200 Emerson epro Proximity Sensor System","description":"\u003cp\u003eThe \u003cstrong\u003eEmerson PR6426-010-100 CON021\/915-200\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003ePR6426\/010\u003c\/strong\u003e Proximity Sensor System, operates as a dedicated hardware component for non-contact shaft vibration and axial position measurement within AMS Machinery Health Monitor platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix \u0026amp; Configuration Structure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransducer Probe (PR6426\/010)\u003c\/strong\u003e: High-temperature eddy-current probe with heavy-duty construction designed for severe vibration monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length (-100)\u003c\/strong\u003e: Integrated armor-protected cable specifying a 10.0 m integral connection path to the signal converter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConverter Module (CON021\/915-200)\u003c\/strong\u003e: Matched signal converter providing regulated oscillator excitation and linear signal conditioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Performance Data\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePR6426-010-100 CON021\/915-200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson \/ epro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.85 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e22.0 cm x 16.5 cm x 7.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 deg C to +180 deg C (Probe head)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.8 W via CON021 converter loop supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Span\u003c\/td\u003e\n\u003ctd\u003e4.0 mm linear measurement range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003eRaw AC voltage \/ proportional DC voltage output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Housing\u003c\/td\u003e\n\u003ctd\u003eStainless steel thread with rugged tip design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSignal Transmission \u0026amp; DCS Integration\u003c\/h3\u003e\n\u003cp\u003eThe transducer generates high-frequency electromagnetic fields that induce eddy currents in target shaft surfaces. Distance variations change coil impedance, which the CON021\/915-200 converter processes into proportional physical displacement signals. Incorporating channel-to-channel isolation safeguards output integrity when interfaced to plant-wide DCS platforms and 4-20 mA HART loop protocol monitoring modules.\u003c\/p\u003e\n\u003ch3\u003eScope of Delivery\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Emerson epro PR6426-010-100 eddy-current probe with 10.0 m integral armored cable\u003c\/li\u003e\n\u003cli\u003e1 x CON021\/915-200 signal converter unit\u003c\/li\u003e\n\u003cli\u003e2 x Stainless steel mounting locknuts\u003c\/li\u003e\n\u003cli\u003e1 x Factory test calibration datasheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Field Installation Instructions\u003c\/h3\u003e\n\u003ch4\u003eProbe Mount \u0026amp; Spatial Clearance\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSecure probe housing in tapped brackets using double locknuts to lock final gap alignment.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum 20 mm unthreaded radial clearance around the sensor tip head to prevent false readings from adjacent machine walls.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eConverter Mounting \u0026amp; Shielding Rules\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSnap the CON021 converter onto standard 35 mm DIN rails inside field terminal boxes.\u003c\/li\u003e\n\u003cli\u003eConnect the cable outer shield bar exclusively to earth ground at the converter housing to eliminate earth loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat main measuring task does the PR6426-010-100 system perform?\u003c\/p\u003e\n\u003cp\u003eIt monitors non-contact radial vibration, shaft position, and thrust wear on heavy industrial rotating machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat does the CON021\/915-200 designation represent?\u003c\/p\u003e\n\u003cp\u003eIt represents the matched signal converter module configured for processing the probe's raw impedance signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan field technicians trim the 10.0 m integral probe cable?\u003c\/p\u003e\n\u003cp\u003eNo, altering cable length changes total system inductance and permanently invalidates factory gap calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the PR6426 probe tip resistant to high operating temperatures?\u003c\/p\u003e\n\u003cp\u003eYes, the probe head operates reliably in extreme temperatures ranging from -35 deg C up to +180 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does channel isolation benefit DCS loop connectivity?\u003c\/p\u003e\n\u003cp\u003eGalvanic channel-to-channel isolation prevents stray ground currents from corrupting analog signals in plant networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat monitoring platforms interface with this proximity system?\u003c\/p\u003e\n\u003cp\u003eIt connects directly to Emerson CSI 6500 racks and AMS machinery protection monitoring systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are signal interference issues mitigated during installation?\u003c\/p\u003e\n\u003cp\u003eEnsuring adequate radial metal clearance around the sensor head prevents unwanted magnetic field degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the converter module require routine field recalibration?\u003c\/p\u003e\n\u003cp\u003eNo, system components are factory-calibrated as a matched pair; field checks only verify zero and span gap settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":50522737246381,"sku":"PR6426-010-100 CON021\/915-200","price":599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/emerson-pr6426-010-000-con021-916-160-epro-plc-module-04u4vkxejn3.jpg?v=1766986776","url":"https:\/\/www.maxwellplc.com\/ru\/products\/pr6426-010-100-con021-915-200-emerson-epro-proximity-sensor-system","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}