{"product_id":"pepperl-fuchs-kfd2-sot3-ex1-lb-k-system-switch-amplifier","title":"Pepperl+Fuchs KFD2-SOT3-EX1.LB K-System Switch Amplifier","description":"\u003cp\u003eConfigured for discrete control signal transfer and fault monitoring in hazardous areas, the \u003cstrong\u003ePepperl+Fuchs KFD2-SOT3-EX1.LB\u003c\/strong\u003e (\u003cstrong\u003eKFD2-SOT3-EX1.LB\u003c\/strong\u003e Switch Amplifier) provides direct physical signal execution by isolating NAMUR sensors or dry contacts located in explosive atmospheres from control system logic inputs.\u003c\/p\u003e\n\u003ch3\u003eModel Designation and Suffix Architecture\u003c\/h3\u003e\n\u003cp\u003eThe complete manufacturer ordering designation is \u003cstrong\u003eKFD2-SOT3-EX1.LB\u003c\/strong\u003e, belonging to the Pepperl+Fuchs K-System isolation barrier product family. The model string elements denote a dual-rail power feed architecture, transistor output configuration (SOT3), single-channel Ex-i input structure (EX1), and integrated line fault transparency functionality (.LB).\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKFD2-SOT3-EX1.LB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSwitch Amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eK-System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.17 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e15 x 12 x 3.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1.3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput and Output Configuration\u003c\/td\u003e\n\u003ctd\u003e1-channel NAMUR input, transistor output with line fault detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type and Range\u003c\/td\u003e\n\u003ctd\u003eDiscrete switching signals per EN 60947-5-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation between input, output, and power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN-rail mounting per EN 60715\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIntrinsic Safety Barriers and Surge Protection Limits\u003c\/h3\u003e\n\u003cp\u003eAs an intrinsic safety interface component, the KFD2-SOT3-EX1.LB incorporates galvanic isolation barriers to prevent high fault voltages from transferring into explosive atmospheres. The circuitry limits electrical energy parameters to safe thresholds, protecting field instrumentation installed in hazardous locations. Furthermore, integrated surge voltage protection limits safeguard internal solid-state components against transient voltage spikes originating from long field cabling runs.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information and Package Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Pepperl+Fuchs KFD2-SOT3-EX1.LB Switch Amplifier\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN-Rail Mounting:\u003c\/strong\u003e Secure the housing firmly onto a standard 35 mm DIN rail inside a protective control cabinet enclosure, maintaining vertical orientation to facilitate proper convective thermal dissipation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e Terminate signal cable shields at the designated control panel ground bar to mitigate electromagnetic interference and maintain high noise immunity across discrete control loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Wiring:\u003c\/strong\u003e Connect field conductors to removable screw or spring terminals using stranded or solid copper wires, adhering strictly to recommended strip lengths and tightening torque limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearance Verification:\u003c\/strong\u003e Ensure sufficient physical separation between intrinsically safe wiring terminals and non-intrinsically safe conductors in accordance with regional hazardous area separation codes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the primary function of the Pepperl+Fuchs KFD2-SOT3-EX1.LB?\u003c\/p\u003e\n\u003cp\u003eA: It serves as a switch amplifier designed to isolate and transfer discrete NAMUR sensor signals from hazardous areas to safe-area control systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What does the .LB designation indicate in the model number?\u003c\/p\u003e\n\u003cp\u003eA: The .LB designation indicates integrated line fault transparency features for detecting sensor open-circuit and short-circuit conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What type of output stage does this switch amplifier provide?\u003c\/p\u003e\n\u003cp\u003eA: It is equipped with a transistor output stage (SOT3 configuration) for reliable solid-state switching execution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What operational temperature range is specified for this module?\u003c\/p\u003e\n\u003cp\u003eA: The hardware is rated for continuous reliable operation in ambient environments ranging from -20 deg C to +60 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How is the module secured inside an industrial control panel?\u003c\/p\u003e\n\u003cp\u003eA: It is engineered for rapid snap-on mounting onto standard 35 mm DIN rails complying with EN 60715 standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the unit provide galvanic isolation across circuits?\u003c\/p\u003e\n\u003cp\u003eA: Yes, it provides complete galvanic isolation separating input circuits, output channels, and the power supply rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What maximum power consumption should be planned for the module?\u003c\/p\u003e\n\u003cp\u003eA: The unit operates with a power consumption of less than 1.3 W under normal active switching conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What maintenance checks should be performed periodically?\u003c\/p\u003e\n\u003cp\u003eA: Technicians should inspect terminal block screw tightness, verify LED status indicators, and check enclosure cleanliness.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":47508763705517,"sku":"KFD2-SOT3-EX1.LB","price":141.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/kfd2-sot3-ex1.lb_1.jpg?v=1792986827","url":"https:\/\/www.maxwellplc.com\/ru\/products\/pepperl-fuchs-kfd2-sot3-ex1-lb-k-system-switch-amplifier","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}