{"product_id":"pepperl-fuchs-kfd2-eb2-power-feed-module-k-system","title":"Pepperl+Fuchs KFD2-EB2 Power Feed Module K-System","description":"\u003cp data-path-to-node=\"6\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"6\" data-index-in-node=\"4\"\u003ePepperl+Fuchs KFD2-EB2\u003c\/b\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e also cataloged as the \u003c\/span\u003e\u003cb data-path-to-node=\"6\" data-index-in-node=\"50\"\u003eKFD2-EB2\u003c\/b\u003e\u003cspan\u003e Power Feed Module,\u003c\/span\u003e\u003cspan\u003e operates as a power distribution and fault monitoring component for the K-System DIN-rail interface module infrastructure.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eModel Configuration\u003c\/h3\u003e\n\u003cp data-path-to-node=\"8\"\u003e\u003cspan\u003eThe complete ordering code designates the standard DIN-rail powered feed module version equipped with collective error messaging functionality.\u003c\/span\u003e\u003cspan\u003e Suffix variants within the K-System power feed family typically denote terminal block types (screw terminals versus spring terminals) and electronic fault output characteristics,\u003c\/span\u003e\u003cspan\u003e though the base unit utilizes standard removable screw terminals.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"10\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,1,1,0\"\u003eKFD2-EB2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,2,1,0\"\u003ePepperl+Fuchs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,3,0,0\"\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,3,1,0\"\u003ePower Feed Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,4,0,0\"\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,4,1,0\"\u003eK-System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,5,0,0\"\u003eSupply Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,5,1,0\"\u003e19 to 30 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,6,0,0\"\u003eRated Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,6,1,0\"\u003eMax. 4 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,7,0,0\"\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,7,1,0\"\u003e\u003cspan class=\"math-inline\" data-math=\"\\le 2.0\\text{ W}\" data-index-in-node=\"0\"\u003e$\\le 2.0\\text{ W}$\u003c\/span\u003e (at 24 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,8,0,0\"\u003eFault Indication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,8,1,0\"\u003eRed LED for collective error \/ fuse failure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,9,0,0\"\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,9,1,0\"\u003e-20 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,10,0,0\"\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,10,1,0\"\u003e35 mm DIN rail (acc. to EN 60715)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,11,0,0\"\u003eProtection Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,11,1,0\"\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,12,0,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,12,1,0\"\u003eApprox. 150 g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"11\"\u003ePower Distribution and Collective Error Monitoring\u003c\/h3\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"4\"\u003ePepperl+Fuchs KFD2-EB2\u003c\/b\u003e\u003cspan\u003e supplies operating power to multiple K-System isolation barriers and signal conditioners via the Power Rail DIN-rail profile,\u003c\/span\u003e\u003cspan\u003e eliminating the need for individual module power wiring.\u003c\/span\u003e\u003cspan\u003e The module monitors the internal power bus for supply voltage drops or module faults.\u003c\/span\u003e\u003cspan\u003e When an error or blown internal fuse occurs on the power rail,\u003c\/span\u003e\u003cspan\u003e the unit triggers a collective error message through a relay contact output,\u003c\/span\u003e\u003cspan\u003e allowing centralized alarm integration into the control system or PLC digital input card.\u003c\/span\u003e\u003cspan\u003e Dual redundant power supply inputs allow primary and backup 24 VDC sources to be connected simultaneously with diode decoupling.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"13\"\u003eInstallation and Electrical Integration\u003c\/h3\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cspan\u003eMount the module directly onto a standard 35 mm DIN rail incorporating the Power Rail profile.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cspan\u003eConnect primary 24 VDC supply voltage to terminals designated for power input,\u003c\/span\u003e\u003cspan\u003e observing correct polarity.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cspan\u003eWire secondary redundant 24 VDC supply to the auxiliary input terminals if dual-source configuration is utilized.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cspan\u003eConnect the collective error relay output terminals to the plant alarm system or monitoring PLC.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,4,0\"\u003e\u003cspan\u003eEnsure total current draw of connected K-System modules does not exceed the 4 A rating of the feed module.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,5,0\"\u003e\u003cspan\u003eMaintain adequate vertical clearance around the DIN rail housing to support natural convection cooling within the control cabinet.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"15\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003e\u003cspan\u003eQ:\u003c\/span\u003e\u003cspan\u003e What is the primary function of the Pepperl+Fuchs KFD2-EB2?\u003c\/span\u003e\u003cspan\u003e A:\u003c\/span\u003e\u003cspan\u003e It distributes 24 VDC operating power to K-System signal conditioners via the DIN-rail power bus and monitors for supply faults.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,1,0\"\u003e\u003cspan\u003eQ:\u003c\/span\u003e\u003cspan\u003e Does the module support redundant power supplies?\u003c\/span\u003e\u003cspan\u003e A:\u003c\/span\u003e\u003cspan\u003e Yes,\u003c\/span\u003e\u003cspan\u003e it accepts dual 24 VDC supply inputs with internal diode decoupling for primary and backup power configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,2,0\"\u003e\u003cspan\u003eQ:\u003c\/span\u003e\u003cspan\u003e How is the collective error signal transmitted?\u003c\/span\u003e\u003cspan\u003e A:\u003c\/span\u003e\u003cspan\u003e It uses an integrated relay contact output that switches when a power rail fault or internal fuse failure is detected.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,3,0\"\u003e\u003cspan\u003eQ:\u003c\/span\u003e\u003cspan\u003e What is the maximum current capacity of the power feed module?\u003c\/span\u003e\u003cspan\u003e A:\u003c\/span\u003e\u003cspan\u003e The module supports a maximum total current output of 4 A across the connected K-System modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,4,0\"\u003e\u003cspan\u003eQ:\u003c\/span\u003e\u003cspan\u003e What type of DIN rail is required for installation?\u003c\/span\u003e\u003cspan\u003e A:\u003c\/span\u003e\u003cspan\u003e It mounts on a standard 35 mm DIN rail in accordance with EN 60715,\u003c\/span\u003e\u003cspan\u003e typically utilizing the Power Rail insert.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,5,0\"\u003e\u003cspan\u003eQ:\u003c\/span\u003e\u003cspan\u003e What is the operating temperature range?\u003c\/span\u003e\u003cspan\u003e A:\u003c\/span\u003e\u003cspan\u003e The module operates reliably within a temperature range of -20 to 60 deg C.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,6,0\"\u003e\u003cspan\u003eQ:\u003c\/span\u003e\u003cspan\u003e What indication does the unit provide for operational status?\u003c\/span\u003e\u003cspan\u003e A:\u003c\/span\u003e\u003cspan\u003e It features front-panel LED indicators for power availability and a red LED for collective error or fuse status.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,7,0\"\u003e\u003cspan\u003eQ:\u003c\/span\u003e\u003cspan\u003e What is the power consumption of the device itself?\u003c\/span\u003e\u003cspan\u003e A:\u003c\/span\u003e\u003cspan\u003e The internal power consumption of the module is approximately 2.\u003c\/span\u003e\u003cspan\u003e0 W at 24 VDC input.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":47508765376685,"sku":"KFD2-EB2-PEPPERL+FUCHS","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/kfd2-eb2_2.jpg?v=1792985801","url":"https:\/\/www.maxwellplc.com\/ru\/products\/pepperl-fuchs-kfd2-eb2-power-feed-module-k-system","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}