{"product_id":"omron-v680-hs52-w-cylindrical-antenna-v680-series","title":"Omron V680-HS52-W Cylindrical Antenna V680 Series","description":"\u003cp\u003eConfigured for high-frequency non-contact RFID tag communication in deterministic networks, the \u003cstrong\u003eOmron V680-HS52-W\u003c\/strong\u003e (\u003cstrong\u003eV680-HS52\u003c\/strong\u003e Cylindrical Antenna) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eModel Nomenclature \u0026amp; Configuration\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eV680-HS52-W\u003c\/strong\u003e designation identifies specific mechanical and electrical features within the V680 RFID platform.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eV680\u003c\/strong\u003e: Base high-frequency industrial RFID series operating at 13.56 MHz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHS\u003c\/strong\u003e: Head system antenna unit designed for read\/write module integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e52\u003c\/strong\u003e: M22 thread diameter form factor with standard sensing distance limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eW\u003c\/strong\u003e: Standard cable configuration featuring an integrated waterproof connector body.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; Electrical Performance\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eV680-HS52-W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCylindrical Antenna\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eM22 x 65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.85 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to 60 deg C (no icing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e20 MOhm min. at 500 VDC between cable terminals and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e10 to 500 Hz, 1.5-mm double amplitude at 100 m\/s2, 10 sweeps in X, Y, Z for 8 min each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e500 m\/s2 in X, Y, and Z directions 3 times each (18 times total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Architecture\u003c\/td\u003e\n\u003ctd\u003eBackplane bus communication velocity Licences compatible via V680 controllers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network \u0026amp; Bus Integrity\u003c\/h3\u003e\n\u003cp\u003eThe antenna assembly operates in tandem with V680 ID controllers to achieve deterministic network scan times across EtherNet\/IP and Profinet architectures. Signal execution relies on stable backplane processing speed to maintain synchronization during high-speed tag pass-by operations. Noise immunity performance prevents firmware flash compatibility mismatches when routing raw RF data to upper-level PLC processors.\u003c\/p\u003e\n\u003ch3\u003eSupplied Components List\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x V680-HS52-W cylindrical antenna unit with attached standard waterproof cable\u003c\/li\u003e\n\u003cli\u003e2x Brass mounting jam nuts for M22 threaded body securing\u003c\/li\u003e\n\u003cli\u003e1x Standard mounting washer set\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMounting \u0026amp; Wiring Procedures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMaintain a metal-free zone around the sensing head to prevent attenuation of the 13.56 MHz electromagnetic field.\u003c\/li\u003e\n\u003cli\u003eTorque the M22 mounting nuts to a maximum limit of 20 N m to prevent mechanical deformation of the outer housing.\u003c\/li\u003e\n\u003cli\u003eGround the cable shield terminal at the controller side to avoid ground loops and low-frequency noise coupling.\u003c\/li\u003e\n\u003cli\u003eSecure the waterproof connector firmly without exceeding the minimal bending radius of the standard cable during execution.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Questions \u0026amp; Answers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the primary purpose of the waterproof connector on the V680-HS52-W?\u003c\/p\u003e\n\u003cp\u003eIt protects signal integrity at the terminal coupling from moisture ingress and fluid splash in wet processing areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the antenna housing require grounding through the panel?\u003c\/p\u003e\n\u003cp\u003eNo, internal shielding routes through the cable connector, but insulation must exceed 20 MOhm at 500 VDC from the case.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does external metal affect the M22 cylindrical body installation?\u003c\/p\u003e\n\u003cp\u003eSurrounding metals alter the inductance, which decreases read\/write communication range if metal-free zones are ignored.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the antenna cable be cut or spliced directly in the field?\u003c\/p\u003e\n\u003cp\u003eSplicing is prohibited because altering cable length disrupts impedance matching required for 13.56 MHz RF execution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat causes communication retries during high-speed tag reads?\u003c\/p\u003e\n\u003cp\u003eExtreme vibration or improper backplane synchronization timings between controller and PLC network modules cause retries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does temperature affect the insulation performance?\u003c\/p\u003e\n\u003cp\u003eOperating outside -10 deg C to 60 deg C causes thermal stress, degrading insulation below the 20 MOhm threshold.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat mechanical force limits apply to the antenna face?\u003c\/p\u003e\n\u003cp\u003eImpacts must not exceed 500 m\/s2 in X, Y, or Z axes to prevent cracking the internal ferrite and coil structure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this antenna compatible with non-V680 series tag controllers?\u003c\/p\u003e\n\u003cp\u003eNo, impedance matching and signal modulation limits restrict execution exclusively to Omron V680 controller channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306618536109,"sku":"V680-HS52-W","price":105.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/v680-hs52-w0.jpg?v=1790391369","url":"https:\/\/www.maxwellplc.com\/ru\/products\/omron-v680-hs52-w-cylindrical-antenna-v680-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}