{"product_id":"omron-nx-eic202-nx-series-ethernet-ip-coupler-unit","title":"Omron NX-EIC202 NX-series EtherNet\/IP Coupler Unit","description":"\u003cp data-path-to-node=\"4\"\u003eThe \u003cb data-path-to-node=\"4\" data-index-in-node=\"4\"\u003eOmron NX-EIC202\u003c\/b\u003e, also cataloged as the \u003cb data-path-to-node=\"4\" data-index-in-node=\"43\"\u003eNX-EIC202\u003c\/b\u003e Coupler Unit, operates as a dedicated hardware component for fieldbus packet translation and slave bus management within EtherNet\/IP network platforms.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"5\"\u003ePart Number Code Interpretation\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eNX\u003c\/b\u003e: Compact I\/O system base product line.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eEIC\u003c\/b\u003e: EtherNet\/IP communication coupler module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003e202\u003c\/b\u003e: Standard functional specification revision supporting implicit and explicit CIP messaging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eTechnical Performance Matrix\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"8\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,1,0\"\u003eNX-EIC202\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,1,0\"\u003eOmron\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,0,0\"\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,1,0\"\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,0,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,1,0\"\u003e0.110 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,0,0\"\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,1,0\"\u003e0.350 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,0,0\"\u003ePhysical Dimensions (L x W x H)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,1,0\"\u003e10.00 cm x 4.60 cm x 7.10 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,0,0\"\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,1,0\"\u003e15.00 cm x 10.00 cm x 8.00 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,0,0\"\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,1,0\"\u003e0 to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,0,0\"\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,1,0\"\u003e1.25 W max\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,0,0\"\u003ePower Supply Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,1,0\"\u003e24 VDC (20.4 to 28.8 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,11,0,0\"\u003eCommunication Ports\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,11,1,0\"\u003e2 x RJ45 (100Base-TX)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,12,0,0\"\u003eMax I\/O Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,12,1,0\"\u003eUp to 63 NX-series I\/O units\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,13,0,0\"\u003ePacket Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,13,1,0\"\u003eUp to 10000 pps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eDeterministic Network Bus Architecture\u003c\/h3\u003e\n\u003cp data-path-to-node=\"10\"\u003eThe module utilizes an internal backplane bus communication velocity profile designed for high-density I\/O data refresh cycles across downstream expansion blocks. Real-time CIP messaging protocol engines maintain low-jitter EtherNet\/IP determinism, while integrated firmware flash compatibility ensures synchronized operational execution during dynamic network topology changes.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"11\"\u003eDeliverable Package Breakdown\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e1 x Omron NX-EIC202 EtherNet\/IP Coupler Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e1 x Bus end cover\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e1 x Installation manual sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003eField Installation \u0026amp; Wiring Guidelines\u003c\/h3\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003eSecure the module onto a standard 35 mm DIN rail in a horizontal orientation inside an IP54-rated industrial cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003eConnect the 24 VDC system power supply using twisted-pair copper conductors with cross-section areas between 0.2 mm2 and 2.5 mm2.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003eEnsure standard Ethernet CAT5e or CAT6 shielded cable connections are routed away from high-voltage AC motor drives.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003eGround the functional earth terminal via a dedicated copper wire directly connected to the cabinet earth bar.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"15\"\u003eTechnical Support FAQ\u003c\/h3\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003eWhat is the maximum number of NX I\/O units that can be attached to one NX-EIC202?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,0,1\"\u003eA single coupler unit controls up to 63 connected NX I\/O units along the right-side local expansion backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,1,0\"\u003eDoes the NX-EIC202 support hot-swapping of attached I\/O modules during operation?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,1,1\"\u003eNo, power to the coupler and total backplane must be turned off before replacing or adding attached I\/O units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,2,0\"\u003eHow are IP address settings configured on the NX-EIC202 coupler?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,2,1\"\u003eIP addresses are assigned via hardware rotary switches located on the front panel or configured via Sysmac Studio software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,3,0\"\u003eWhat communication topologies are supported by the dual RJ45 Ethernet ports?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,3,1\"\u003eThe onboard dual ports support star, daisy-chain, and ring network topologies via EtherNet\/IP CIP messaging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,4,0\"\u003eWhat type of cable shield grounding is recommended for the communication lines?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,4,1\"\u003eUse double-shielded STP cables grounded at both switch ends to prevent industrial electromagnetic noise interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,5,0\"\u003eIs external power supply wiring required for downstream I\/O module operation?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,5,1\"\u003eYes, separate power connections are required for internal logic circuit supply and field output load power lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,6,0\"\u003eHow does the coupler indicate internal CPU or communication fault status?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,6,1\"\u003eStatus indicators labeled MS (Module Status), NS (Network Status), and IO PWR display solid or flashing diagnostic LEDs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,7,0\"\u003eWhat is the maximum length per EtherNet\/IP network segment connected to the unit?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,7,1\"\u003eThe maximum physical cable length between the coupler and the adjacent network switch or node is 100 meters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306664575149,"sku":"NX-EIC202","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/NX-EIC202-1.jpg?v=1790689450","url":"https:\/\/www.maxwellplc.com\/ru\/products\/omron-nx-eic202-nx-series-ethernet-ip-coupler-unit","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}