{"product_id":"omron-nsj5-tq01b-g5d-human-machine-interface-nsj-series","title":"Omron NSJ5-TQ01B-G5D Human Machine Interface NSJ Series","description":"\u003cp\u003eConfigured for integrated PLC control execution and graphical display operations in DeviceNet fieldbus networks, the \u003cstrong\u003eOmron NSJ5-TQ01B-G5D\u003c\/strong\u003e (\u003cstrong\u003eNSJ5-TQ01\u003c\/strong\u003e Human Machine Interface) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eNomenclature Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNSJ5\u003c\/strong\u003e: Integrated HMI-PLC unit with 5.7-inch screen size footprint.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTQ01\u003c\/strong\u003e: TFT color LCD panel with QVGA display resolution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB\u003c\/strong\u003e: Black enclosure frame finish.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eG5D\u003c\/strong\u003e: Built-in CJ1-series PLC processing engine with DeviceNet master interface and 24 VDC input.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFunctional Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNSJ5-TQ01B-G5D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.99 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e195 mm x 142 mm x 79 mm (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e25 W max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Program Memory\u003c\/td\u003e\n\u003ctd\u003e60 K Steps (Advanced CPU 45H) \/ 20 K Steps (Basic CPU 13H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Memory\u003c\/td\u003e\n\u003ctd\u003e128 K words (Advanced CPU 45H) \/ 32 K words (Basic CPU 13H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-board Fieldbus\u003c\/td\u003e\n\u003ctd\u003eDeviceNet Master (Up to 32,000 distributed I\/O points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Racks\u003c\/td\u003e\n\u003ctd\u003e3 max (Advanced CPU 45H) \/ 1 max (Basic CPU 13H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePLC Engine Integration and System Memory Management\u003c\/h3\u003e\n\u003cp\u003eThe integrated CJ1 controller architecture maintains high backplane bus communication velocity Licences and deterministic internal memory mapping between the PLC engine and display hardware. Dedicated internal memory channels eliminate external communication latencies during high-density I\/O register exchanges. Flash memory management reserves dedicated blocks for function block program data (1024 KB), comment files (64 KB), program index files (64 KB), and symbol tables (64 KB). System execution maintains strict firmware flash compatibility across CX-One development environments.\u003c\/p\u003e\n\u003ch3\u003eSystem Supply Items\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron NSJ5-TQ01B-G5D Integrated HMI-PLC Unit\u003c\/li\u003e\n\u003cli\u003e1 x 24 VDC Power Supply Terminal Plug\u003c\/li\u003e\n\u003cli\u003e1 x DeviceNet Fieldbus Connector Block\u003c\/li\u003e\n\u003cli\u003e4 x Panel Mounting Clamps and Retaining Screws\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Installation and Power Grounding\u003c\/h3\u003e\n\u003ch4\u003eDoor Panel Cutout\u003c\/h4\u003e\n\u003cp\u003eCut a clean rectangular opening in the enclosure door according to standard panel dimensions. Maintain at least 100 mm clear perimeter space around top, bottom, and side ventilation slots to enable natural convection airflow.\u003c\/p\u003e\n\u003ch4\u003eBezel Fastening\u003c\/h4\u003e\n\u003cp\u003eVerify that the perimeter rubber seal is properly seated inside the bezel channel. Insert the unit into the door opening and tighten all four clamp brackets evenly to maintain IP65 front panel sealing.\u003c\/p\u003e\n\u003ch4\u003ePower and Earth Ground Connections\u003c\/h4\u003e\n\u003cp\u003eConnect a regulated 24 VDC power source using shielded 16 AWG conductors. Wire the Functional Ground (FG) terminal directly to the central enclosure earth bus using a short, low-impedance copper conductor to mitigate high-frequency electrical interference.\u003c\/p\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHow is data exchanged between the internal PLC engine and the display panel?\u003c\/p\u003e\n\u003cp\u003eInternal bus routing maps PLC memory areas directly to screen tags, eliminating serial baud rate delays and ensuring microsecond-level register updates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the unit support hot-swapping connected DeviceNet slave nodes?\u003c\/p\u003e\n\u003cp\u003eDeviceNet network nodes can be connected or disconnected without powering down the master, provided terminal resistors and trunk cable integrity remain intact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens to local I\/O execution if 24 VDC power drops below threshold?\u003c\/p\u003e\n\u003cp\u003eA drop below 20.4 VDC triggers an immediate controller fault state, halting program execution and resetting digital outputs to safe zero states.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the system handle function block memory allocation?\u003c\/p\u003e\n\u003cp\u003eFunction block code is executed from dedicated 1024 KB flash program memory, preserving program execution structure during main DC power loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat routing rules apply to DeviceNet trunk and drop cables?\u003c\/p\u003e\n\u003cp\u003eDeviceNet cables must run through grounded metal conduits separated from 230\/400 VAC power lines and variable frequency drive motor leads by at least 300 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat expansion limit applies to the basic processing controller variant?\u003c\/p\u003e\n\u003cp\u003eBasic controller configurations support a maximum of 1 expansion rack, limiting total local I\/O module footprint compared to advanced controller models.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat precautions are required during program download via CX-One?\u003c\/p\u003e\n\u003cp\u003eMaintain continuous 24 VDC logic power throughout the transfer. Loss of power during firmware or flash sector writes corrupts memory indexes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat mounting angle is required for optimal cabinet thermal dissipation?\u003c\/p\u003e\n\u003cp\u003eMount the display terminal vertically within 30 deg of perpendicular to prevent heat buildup inside the rear CPU and power supply enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306654711981,"sku":"NSJ5-TQ01B-G5D","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/NSJ5-TQ01B-G5D.jpg?v=1790140139","url":"https:\/\/www.maxwellplc.com\/ru\/products\/omron-nsj5-tq01b-g5d-human-machine-interface-nsj-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}