{"product_id":"omron-drt2-ros16-remote-i-o-terminal-devicenet-series","title":"Omron DRT2-ROS16 Remote I\/O Terminal DeviceNet Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron DRT2-ROS16\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDRT2-ROS16\u003c\/strong\u003e Remote I\/O Terminal, operates as a dedicated hardware component for relay output execution and load switching within DeviceNet control networks.\u003c\/p\u003e\n\u003ch3\u003eModel Nomenclature Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDRT2\u003c\/strong\u003e: Smart Slave terminal platform with integrated maintenance diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRO\u003c\/strong\u003e: Relay output functional contact architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eS\u003c\/strong\u003e: Screw terminal block wiring structure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16\u003c\/strong\u003e: 16-point relay output point count.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Electrical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDRT2-ROS16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.260 kg max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e15 x 15 x 5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eCommunications: 215 mA max. at 24 VDC, 395 mA max. at 11 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounted Relays\u003c\/td\u003e\n\u003ctd\u003eDRTA-NY5W-K (plug-in replaceable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Load\u003c\/td\u003e\n\u003ctd\u003e2 A at 250 VAC, 2 A at 30 VDC (8 A per common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Contact Voltage\u003c\/td\u003e\n\u003ctd\u003e250 VAC, 125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Switching Capacity\u003c\/td\u003e\n\u003ctd\u003e750 VA AC, 90 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Applicable Load\u003c\/td\u003e\n\u003ctd\u003e1 mA at 5 VDC (reference value)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e500 VAC (between isolated circuits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e20 MOhm min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Immunity\u003c\/td\u003e\n\u003ctd\u003eConforms to IEC 61000-4-4, 2 kV (power line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003e35-mm DIN rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Operations \u0026amp; Output Control\u003c\/h3\u003e\n\u003cp\u003eThe DRT2-ROS16 executes output command updates with high determinism across DeviceNet networks. Internal logic handles contact cycle counting and operational runtime accumulators without causing backplane bus communication velocity bottlenecks. Built-in firmware flash compatibility supports dynamic field diagnostic reporting and maintenance monitoring across I\/O density scaling configurations.\u003c\/p\u003e\n\u003ch3\u003eShipping Box Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron DRT2-ROS16 Remote Relay Output Terminal\u003c\/li\u003e\n\u003cli\u003e1 x DeviceNet Open Connector\u003c\/li\u003e\n\u003cli\u003e1 x Technical Instruction Leaflet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Mounting \u0026amp; Wiring Directives\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDIN-Rail Terminal Mounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMount the terminal onto a standard 35-mm DIN rail and secure the end stoppers on both sides.\u003c\/li\u003e\n\u003cli\u003eTighten M3 panel mounting screws to 0.5 N m if mounting directly onto an enclosure backplate.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eField Wiring \u0026amp; Terminal Torque\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWire output loads to the M3 terminal block, tightening screws to a torque rating of 0.5 N m.\u003c\/li\u003e\n\u003cli\u003eFasten the M2 communications connector screws to a torque rating of 0.2 to 0.3 N m to preserve terminal integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eAre the individual output relays replaceable on the DRT2-ROS16 terminal board?\u003c\/p\u003e\n\u003cp\u003eYes, the terminal utilizes plug-in DRTA-NY5W-K relays designed for single-step relay replacement during field maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum load current allowed per common terminal group?\u003c\/p\u003e\n\u003cp\u003eThe maximum continuous current rating per common terminal line is 8 A across the output contact grouping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat power supply voltage range is required for DeviceNet communication?\u003c\/p\u003e\n\u003cp\u003eThe terminal operates on a communications power supply voltage of 11 to 25 VDC provided through the network bus connector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the minimum signal load that the relay contacts can reliably switch?\u003c\/p\u003e\n\u003cp\u003eThe minimum applicable reference load for the contacts is 1 mA at 5 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat level of electrical noise immunity does the terminal feature?\u003c\/p\u003e\n\u003cp\u003eThe unit conforms to the IEC 61000-4-4 standard for fast transient noise immunity up to 2 kV on power lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the DRT2-ROS16 be mounted directly to an enclosure panel without a DIN rail?\u003c\/p\u003e\n\u003cp\u003eYes, the housing includes M3 screw mounting holes alongside the 35-mm DIN rail lock mechanism.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum AC switching capacity supported per relay output channel?\u003c\/p\u003e\n\u003cp\u003eEach output contact supports a maximum switching capacity of 750 VA AC under resistive load conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat storage temperature limits must be observed for unused replacement units?\u003c\/p\u003e\n\u003cp\u003eThe device can be safely stored in non-condensing environments maintained between -25 deg C and 65 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306618372269,"sku":"DRT2-ROS16","price":230.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/omron_drt2-ros16_1.jpg?v=1789695268","url":"https:\/\/www.maxwellplc.com\/ru\/products\/omron-drt2-ros16-remote-i-o-terminal-devicenet-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}