{"product_id":"omron-cp1l-m60dt-d-cp1l-series-programmable-logic-controller","title":"Omron CP1L-M60DT-D CP1L Series Programmable Logic Controller","description":"\u003ch2\u003eOmron CP1L-M60DT-D CP1L Series Programmable Logic Controller\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-speed logic processing, multi-axis positioning, and discrete sensor interfacing in industrial automation networks, the \u003cstrong\u003eOmron CP1L-M60DT-D\u003c\/strong\u003e (\u003cstrong\u003eCP1L-M60DT-D\u003c\/strong\u003e) CPU Unit provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eIdentifier Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Identifier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCP1L-M60DT-D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCP1L Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 Points Built-in (36 Digital Inputs \/ 24 Transistor Outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransistor Output (Sinking)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10K Steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCP1L-M60DT-D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.5 cm x 11.0 cm x 8.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.0 cm x 14.0 cm x 11.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 W max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStored program method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Control Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCyclic scan with immediate refreshing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgramming Language\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLadder diagram, Structured Text (ST in Function Blocks)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstruction Execution Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic instructions: 0.55 us min. \/ Special instructions: 4.1 us min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgram Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10K steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTask Allocation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e288 total (32 cyclic tasks, 256 interrupt tasks)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHigh-Speed Counters\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kHz, 4 axes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kHz, 2 axes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpansion Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax. 3 CP-series Expansion Units or Expansion I\/O Units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Expanded I\/O Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180 points (60 built-in + 40 per expansion unit x 3 units)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Memory Area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,600 bits (100 words): CIO 0 to CIO 99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWork Bits Area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8,192 bits (512 words): W000.00 to W511.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHolding Memory Area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8,192 bits (512 words): H0.00 to H511.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTimers \/ Counters\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4,096 timers (T0 to T4095) \/ 4,096 counters (C0 to C4095)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eOmron Backplane Bus Velocity \u0026amp; Determinism Architecture\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eOmron CP1L-M60DT-D\u003c\/strong\u003e CPU unit achieves an instruction execution benchmark of 0.55 us for basic ladder operations and 4.1 us for specialized instructions, operating with a deterministic common processing overhead of 0.4 ms. Internal I\/O synchronization utilizes cyclic scanning combined with immediate refreshing to eliminate backplane communication latency across connected CP-series expansion units. The integrated task scheduler handles up to 32 cyclic tasks and 256 interrupt tasks to preserve deterministic execution during concurrent high-density interrupt processing. Built-in high-speed counter channels handle up to 100 kHz input signals across 4 differential or single-ended axes without introducing jitter to CPU scan execution. Dual pulse output channels generate up to 100 kHz pulse trains for high-precision, two-axis motion control. Function block structures support up to 128 definitions and 256 instances, allowing embedded Structured Text (ST) execution within standard ladder cycles.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x Omron CP1L-M60DT-D CPU Unit\u003c\/li\u003e\n\u003cli\u003e1x Removable Terminal Block Assembly (Pre-installed)\u003c\/li\u003e\n\u003cli\u003e1x Hardware Installation Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Structure:\u003c\/strong\u003e Mount the CPU unit vertically onto a 35 mm DIN rail or fasten directly to a panel surface using M4 mounting screws. Maintain a minimum vertical gap of 50 mm above and below the module for airflow and wire trace routing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower \u0026amp; Wiring:\u003c\/strong\u003e Terminate the 24 VDC system power lines at the dedicated DC power terminals using solid or stranded wiring rated between 0.5 mm2 and 1.25 mm2 (AWG 20 to AWG 16). Crimp insulated pin terminals to prevent shorting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding \u0026amp; Grounding:\u003c\/strong\u003e Connect the protective earth (PE) terminal to a dedicated low-impedance ground point using wire with a minimum cross-sectional area of 2.0 mm2. Apply 360-deg braid shielding on high-speed pulse and counter signal cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Terminations:\u003c\/strong\u003e Ensure sinking transistor outputs operate within the maximum switching rating of 24 VDC at 0.3 A per point. Install external flyback suppression diodes across inductive DC loads.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the response frequency capability for the high-speed counter inputs?\u003c\/p\u003e\n\u003cp\u003eThe unit supports 100 kHz response frequency across 4 distinct high-speed counter input axes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the minimum pulse width recognized by quick-response inputs?\u003c\/p\u003e\n\u003cp\u003eQuick-response inputs register digital pulses with a minimum pulse width of 50 us maximum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many total I\/O points can be controlled using expansion modules?\u003c\/p\u003e\n\u003cp\u003eThe system expands up to 180 total I\/O points by connecting up to 3 CP-series expansion units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat language formats are supported inside Function Block definitions?\u003c\/p\u003e\n\u003cp\u003eFunction block definitions support standard Ladder Diagram and Structured Text (ST) coding formats.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the output electrical characteristics on the CP1L-M60DT-D?\u003c\/p\u003e\n\u003cp\u003eThis model features 24 sinking transistor outputs rated for DC loads with 100 kHz pulse train capability on 2 axes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the nominal operating power supply voltage for this unit?\u003c\/p\u003e\n\u003cp\u003eThe module operates on a nominal 24 VDC power supply with a maximum power consumption of 20 W.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many interrupt input points operate in counter mode?\u003c\/p\u003e\n\u003cp\u003eThere are 6 interrupt inputs operating in 16-bit up\/down counter mode with a maximum response frequency of 5 kHz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are user programs and DM area values preserved during power loss?\u003c\/p\u003e\n\u003cp\u003eUser programs and setup parameters write to flash memory, while DM, Holding, and counter data retain state via battery backup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306646388909,"sku":"CP1L-M60DT-D","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CP1L-M60DT-D_1.jpg?v=1788840012","url":"https:\/\/www.maxwellplc.com\/ru\/products\/omron-cp1l-m60dt-d-cp1l-series-programmable-logic-controller","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}