{"product_id":"omron-cp1l-m60dt-a-cp1l-series-programmable-controller","title":"Omron CP1L-M60DT-A CP1L Series Programmable Controller","description":"\u003cp\u003eThe \u003cstrong\u003eOmron CP1L-M60DT-A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCP1L-M60DT-A\u003c\/strong\u003e High Performing Programmable Controller with Embedded Ethernet, operates as a dedicated hardware component for localized sequential logic execution and multi-axis pulse train motion control within CP-series architecture platforms.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model Code:\u003c\/strong\u003e CP1L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Category (M):\u003c\/strong\u003e Monolithic CPU Unit with high-capacity memory (10K steps) and extended I\/O expansion capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Capacity (60):\u003c\/strong\u003e 60 total built-in I\/O points (36 discrete inputs, 24 transistor outputs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Type (T):\u003c\/strong\u003e Transistor sinking outputs supporting 100 kHz pulse outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Type (A):\u003c\/strong\u003e 100 to 240 VAC wide-range power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCP1L-M60DT-A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e19.5 cm x 11.0 cm x 8.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e22.0 cm x 14.0 cm x 11.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e50 VA max. at 100 to 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e100 to 240 VAC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eStored program method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Control Method\u003c\/td\u003e\n\u003ctd\u003eCyclic scan with immediate refreshing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in I\/O Points\u003c\/td\u003e\n\u003ctd\u003e60 points (36 Inputs, 24 Outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eTransistor output (sinking)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Outputs\u003c\/td\u003e\n\u003ctd\u003e100 kHz, 2 axes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Expandable I\/O\u003c\/td\u003e\n\u003ctd\u003e180 points (using up to 3 CP-series expansion units)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExecution Time\u003c\/td\u003e\n\u003ctd\u003eBasic instructions: 0.55 us min. \/ Special instructions: 4.1 us min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Processing Time\u003c\/td\u003e\n\u003ctd\u003e0.4 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Capacity\u003c\/td\u003e\n\u003ctd\u003e10K steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction Block Definitions\u003c\/td\u003e\n\u003ctd\u003e128 max. definitions (256 max. instances)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction Block Languages\u003c\/td\u003e\n\u003ctd\u003eLadder Diagram, Structured Text (ST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTask Configuration\u003c\/td\u003e\n\u003ctd\u003e288 total (32 cyclic tasks, 256 interrupt tasks)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Memory Area\u003c\/td\u003e\n\u003ctd\u003eCIO 0 to CIO 99 (1,600 bits \/ 100 words)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWork Memory Bits\u003c\/td\u003e\n\u003ctd\u003eW0 to W511 (8,192 bits \/ 512 words)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIO Area Extension\u003c\/td\u003e\n\u003ctd\u003eCIO 3800 to CIO 6143 (37,504 bits \/ 2,344 words)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHolding Memory Area\u003c\/td\u003e\n\u003ctd\u003eH0 to H511 (8,192 bits \/ 512 words)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimers \/ Counters\u003c\/td\u003e\n\u003ctd\u003e4,096 Timers (T0 to T4095) \/ 4,096 Counters (C0 to C4095)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-Speed Counters\u003c\/td\u003e\n\u003ctd\u003e100 kHz, 4 axes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupt Inputs\u003c\/td\u003e\n\u003ctd\u003e6 inputs (0.3 ms response time)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick-Response Inputs\u003c\/td\u003e\n\u003ctd\u003e6 points (min. input pulse width 50 us max.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Volatile Backup\u003c\/td\u003e\n\u003ctd\u003eFlash memory for program\/parameters; Battery backup for Holding Area, DM Area, and counter flags\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life Expectancy\u003c\/td\u003e\n\u003ctd\u003e5 years at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePLC Determinism and Backplane Bus Velocity\u003c\/h3\u003e\n\u003cp\u003eThe Omron CP1L-M60DT-A processing architecture is structured for fast cyclic scan execution, executing basic ladder instructions in 0.55 microseconds. The integrated sinking transistor outputs enable direct 2-axis high-speed pulse train output up to 100 kHz, driving positioning tasks alongside 4-axis 100 kHz high-speed counter feedback loops.\u003c\/p\u003e\n\u003cp\u003eSystem expansion remains deterministic through the dedicated lateral backplane bus interface, accommodating up to 3 CP-series expansion or expansion I\/O modules to scale system density up to 180 I\/O points. Cyclic scan cycles execute immediate refreshing across physical terminal states, ensuring real-time synchronized synchronization between memory map registers, execution tasks, and physical peripheral devices.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x Omron CP1L-M60DT-A Programmable Controller Unit\u003c\/li\u003e\n\u003cli\u003e1x Removable Screw Terminal Block Assembly\u003c\/li\u003e\n\u003cli\u003e1x Lithium Backup Battery\u003c\/li\u003e\n\u003cli\u003e1x CP1L Hardware Installation Instruction Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN-Rail Mounting:\u003c\/strong\u003e Secure the unit onto a standard 35 mm DIN rail (PFP-50N\/PFP-100N). Ensure a minimum clearance of 50 mm above and below the housing to maintain natural convection cooling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Power Wiring:\u003c\/strong\u003e Connect 100 to 240 VAC power to the dedicated L1 and L2\/N terminals using stranded copper conductors. Torque terminal screws to 0.5 N-m.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSinking Transistor Load Wiring:\u003c\/strong\u003e Connect the external DC power supply positive rail to the load and wire the negative side to the controller sinking output terminals. Ensure total output current stays within rated limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Setup:\u003c\/strong\u003e Wire the protective earth (PE) terminal to an external ground with an impedance under 100 ohms using a copper wire of at least 1.25 mm sq cross-section.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding Procedures:\u003c\/strong\u003e Apply 360-deg braid shield clamping to high-speed pulse and input line cables to suppress electromagnetic interference and signal degradation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat output technology is integrated into the CP1L-M60DT-A?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit incorporates transistor sinking outputs designed for fast electronic switching and high-speed pulse train control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this CPU support high-speed pulse outputs for motion tasks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the CPU provides 2 axes of high-speed pulse outputs capable of frequencies up to 100 kHz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum number of I\/O points supported with expansion units?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe base unit provides 60 built-in I\/O points and expands up to 180 points using 3 CP-series expansion units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow fast are the basic instruction execution speeds on this CPU?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBasic instructions execute in a minimum processing time of 0.55 microseconds, while special instructions take 4.1 microseconds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat programming languages are supported for function block execution?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFunction block definitions support both Ladder Diagrams and IEC 61131-3 Structured Text (ST).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the capacity and lifespan of the memory backup system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFlash memory saves user programs and parameters permanently, while a lithium battery backs up work registers for up to 5 years at 25 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow many high-speed counter inputs are available on the terminal strip?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CPU provides 4 axes of high-speed counters capable of processing signals up to 100 kHz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow are quick-response input signals handled by the hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit incorporates 6 quick-response input terminals that reliably register input pulses with widths down to 50 microseconds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306636886189,"sku":"CP1L-M60DT-A(SAME DAY DELIVERY)","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CP1L-M60DT-A_1.jpg?v=1788841976","url":"https:\/\/www.maxwellplc.com\/ru\/products\/omron-cp1l-m60dt-a-cp1l-series-programmable-controller","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}