{"product_id":"omron-cj1w-od202-transistor-output-module-sysmac-cj-series","title":"Omron CJ1W-OD202 Transistor Output Module SYSMAC CJ Series","description":"\u003cp\u003eConfigured for high-current discrete switching and field load control in SYSMAC CJ Series systems, the \u003cstrong\u003eOmron CJ1W-OD202\u003c\/strong\u003e (\u003cstrong\u003eCJ1W-OD202\u003c\/strong\u003e Transistor Output Unit) provides direct physical\/electrical execution across 8 sourcing transistor output points.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Hardware Model:\u003c\/strong\u003e CJ1W-OD202\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Part Number:\u003c\/strong\u003e CJ1W-OD202\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Transistor Output Module (Sourcing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Family:\u003c\/strong\u003e Omron SYSMAC CJ Series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Classification:\u003c\/strong\u003e Basic I\/O Unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Configuration:\u003c\/strong\u003e 8 sourcing outputs (4 points\/common, 2 circuits)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Type:\u003c\/strong\u003e Terminal block\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-OD202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.12 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.1 cm x 9.0 cm x 6.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e11.0 cm x 7.0 cm x 13.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e110 mA max at 5 VDC (Internal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Load Voltage Range\u003c\/td\u003e\n\u003ctd\u003e20.4 to 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current\u003c\/td\u003e\n\u003ctd\u003e2 A\/point, 8 A\/Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current\u003c\/td\u003e\n\u003ctd\u003e0.1 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Voltage\u003c\/td\u003e\n\u003ctd\u003e1.5 V max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON Response Time\u003c\/td\u003e\n\u003ctd\u003e0.5 ms max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF Response Time\u003c\/td\u003e\n\u003ctd\u003e1.0 ms max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Short-circuit Protection\u003c\/td\u003e\n\u003ctd\u003eDetection current: 6 A min, automatic restart after error clearance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Disconnection Detection\u003c\/td\u003e\n\u003ctd\u003eDetection current: 200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e20 MOhm min between external terminals and GR terminal (at 100 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e1,000 VAC between external terminals and GR terminal for 1 min (10 mA max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 50 mA min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eOmron Backplane Bus Velocity \u0026amp; Real-Time Logic Execution\u003c\/h3\u003e\n\u003cp\u003eThe CJ1W-OD202 interfaced with the CJ Series CPU backplane maps output bit states directly across the high-speed internal bus, updating physical transistor outputs with maximum execution speeds of 0.5 ms ON and 1.0 ms OFF. Hardware-level short-circuit protection trips at 6 A minimum, automatically restarting output execution following error recovery to maintain high I\/O density scaling and scan determinism. The internal logic circuit draws a low backplane current of 110 mA at 5 VDC, while firmware compatibility allows hardware register assignment across the backplane upon power-up without adding scan delay.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x Omron CJ1W-OD202 Transistor Output Module\u003c\/li\u003e\n\u003cli\u003e1x Terminal block connector kit\u003c\/li\u003e\n\u003cli\u003e1x Hardware specification instruction sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Mounting:\u003c\/strong\u003e Slide the CJ1W-OD202 unit into the CPU or expansion rack slot until the backplane bus connectors align and latch into position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Wiring:\u003c\/strong\u003e Wire field loads to the sourcing terminals using solid or stranded conductors, ensuring correct 24 VDC external power connection to terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Shielding:\u003c\/strong\u003e Enclose field wiring in grounded metallic conduits or continuous 360-deg braid shields to isolate 24 VDC load switching from high-frequency noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Grounding:\u003c\/strong\u003e Connect the rack Ground (GR) terminal directly to panel earth using copper conductor lines with ground loop resistance under 100 Ohms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping supported for the CJ1W-OD202 on a live SYSMAC CJ backplane?\u003c\/p\u003e\n\u003cp\u003eNo. Main power to the CPU rack assembly must be turned off before inserting or removing the module to avoid hardware damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat internal backplane current is required by the CJ1W-OD202?\u003c\/p\u003e\n\u003cp\u003eThe module consumes a maximum of 110 mA at 5 VDC directly from the internal backplane logic power supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat external power source must be connected to drive the output circuitry?\u003c\/p\u003e\n\u003cp\u003eAn external 24 VDC power supply capable of supplying at least 50 mA at 20.4 to 26.4 VDC is required for output execution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the load short-circuit protection function operate?\u003c\/p\u003e\n\u003cp\u003eWhen load current exceeds 6 A minimum, short-circuit protection trips the circuit and automatically restarts operation after the error clears.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the threshold for the line disconnection detection feature?\u003c\/p\u003e\n\u003cp\u003eThe module detects field circuit disconnections when the output load current drops below the 200 mA detection limit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat dielectric strength rating is established for the terminal connections?\u003c\/p\u003e\n\u003cp\u003eInsulation withstands 1,000 VAC for 1 minute between external field terminals and the GR terminal at 10 mA maximum leakage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum allowable load current per individual point and unit?\u003c\/p\u003e\n\u003cp\u003eEach output channel handles up to 2 A maximum, with a total maximum current capacity of 8 A for the entire module unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat grounding resistance standard applies to the GR terminal ground path?\u003c\/p\u003e\n\u003cp\u003eThe GR terminal must be bonded to the central panel earth ground bar maintaining an electrical resistance under 100 Ohms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306615980205,"sku":"CJ1W-OD202","price":124.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CJ1W-OD202_1.jpg?v=1788103514","url":"https:\/\/www.maxwellplc.com\/ru\/products\/omron-cj1w-od202-transistor-output-module-sysmac-cj-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}