{"product_id":"omron-3g3jz-a4037-sysdrive-3g3jz-series-inverter","title":"Omron 3G3JZ-A4037 SYSDRIVE 3G3JZ Series Inverter","description":"\u003cp\u003eThe \u003cstrong\u003eOmron 3G3JZ-A4037\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3G3JZ-A4037\u003c\/strong\u003e Inverter, operates as a dedicated hardware component for pulse-width modulated motor speed control and torque regulation within SYSDRIVE automation platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Identification Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3G3JZ\u003c\/strong\u003e: Base family prefix for compact SYSDRIVE AC variable frequency drive units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Panel-mounting enclosure design conforming to IP20 minimum closed wall mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4\u003c\/strong\u003e: Operating input voltage specification designated for 3-phase AC 400 V power networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e037\u003c\/strong\u003e: Maximum drive power capacity scaled for 3.7 kW induction motors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational Parameters\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3G3JZ-A4037\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Class\u003c\/td\u003e\n\u003ctd\u003e3-phase AC 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Capacity\u003c\/td\u003e\n\u003ctd\u003e3.7 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003ePanel-mounting (IP20 min) \/ Closed wall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to +50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3.7 kW full load power output rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e22.0 x 18.0 x 16.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eNetwork Protocol \u0026amp; Deterministic Control\u003c\/h3\u003e\n\u003cp\u003eThe drive interfaces with PLC host controllers over Modbus RS-485 interfaces to support deterministic networks and real-time parameter configuration. Onboard control logic executes firmware flash compatibility validation upon system power-up to ensure seamless drive control and optimal I\/O density scaling.\u003c\/p\u003e\n\u003ch3\u003eComponent Package Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron 3G3JZ-A4037 Inverter Module\u003c\/li\u003e\n\u003cli\u003e1 x ESD protective chassis wrap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet Installation \u0026amp; Field Wiring Directives\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Mounting Considerations\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSecure the inverter in an upright vertical orientation on a grounded metal backpanel.\u003c\/li\u003e\n\u003cli\u003eMaintain an unimpeded thermal clearance of at least 100 mm above and below the drive chassis.\u003c\/li\u003e\n\u003cli\u003eTighten panel mounting screws securely to satisfy vibration resistance requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Wiring Instructions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTerminate incoming 3-phase AC 400 V power lines to terminals L1, L2, and L3.\u003c\/li\u003e\n\u003cli\u003eAttach three-phase motor leads to terminals T1, T2, and T3 using continuous shielded cable.\u003c\/li\u003e\n\u003cli\u003eGround the drive frame directly to the main enclosure earth bus bar using heavy copper wire.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Support FAQs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat input voltage range does the 3G3JZ-A4037 drive accept?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe drive requires a nominal 3-phase AC 400 V input voltage source for 400 V class AC motor control loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat motor power output rating is supported by this inverter model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis inverter model provides drive output capacity tailored for 3-phase AC motors rated up to 3.7 kW.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs power terminal hot-swapping allowed on this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Input power must be turned off and DC link capacitors discharged prior to servicing power wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the internal control board protected from electrical noise?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eControl lines must use twisted-pair shielded cables separated from motor wiring to avoid interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat structural enclosure protection does this inverter supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit features an IP20 minimum panel-mounting enclosure designed for closed wall cabinet mounting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is cabinet grounding executed for safety and noise suppression?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGrounding connects from the dedicated PE terminal directly to the enclosure grounding rail via copper strap.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the unit handle protocol communication timing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIntegrated serial logic maintains deterministic control timing over Modbus RS-485 network connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat checks occur when replacing or updating drive firmware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSystem initialization routines run firmware flash compatibility checks prior to executing motor control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306657923245,"sku":"3G3JZ-A4037","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/omron_3g3jz-a4037_2.jpg?v=1787720290","url":"https:\/\/www.maxwellplc.com\/ru\/products\/omron-3g3jz-a4037-sysdrive-3g3jz-series-inverter","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}