{"product_id":"nx1p2-1140dt1-omron-sysmac-nx1p-cpu","title":"NX1P2-1140DT1 Omron Sysmac NX1P CPU","description":"\u003cp data-path-to-node=\"4\"\u003eConfigured for high-speed motion control and industrial process synchronization in industrial automation networks, the \u003cb data-path-to-node=\"4\" data-index-in-node=\"119\"\u003eOmron NX1P2-1140DT1\u003c\/b\u003e (\u003cb data-path-to-node=\"4\" data-index-in-node=\"140\"\u003eNX1P2-1140DT1\u003c\/b\u003e Sysmac NX1P CPU) provides direct physical\/electrical execution. It coordinates sequence control and motion processing across local I\/O cards and fieldbus nodes, supporting up to 40 direct digital I\/O points alongside integrated EtherCAT and EtherNet\/IP communications.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"5\"\u003ePart Number Nomenclature \u0026amp; Variant Index\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eNX1P2\u003c\/b\u003e: Sysmac compact machine controller processor family.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003e1140\u003c\/b\u003e: Standard performance CPU core with 40 built-in direct I\/O points (24 NPN\/PNP inputs, 16 PNP outputs).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eD\u003c\/b\u003e: Direct current (DC) supply voltage execution architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eT1\u003c\/b\u003e: Transistor PNP logic output array for field actuator control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eCore System Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"8\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,1,0\"\u003eNX1P2-1140DT1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,1,0\"\u003eOmron\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,0,0\"\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,1,0\"\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,0,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,1,0\"\u003e0.66 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,0,0\"\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,1,0\"\u003e7.1 cm x 14.8 cm x 10.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,0,0\"\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,1,0\"\u003e0 to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,0,0\"\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,1,0\"\u003e16.0 W max\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,0,0\"\u003ePrimary Task Cycle Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,1,0\"\u003e2 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,0,0\"\u003eProgram Memory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,1,0\"\u003e1.5 MB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,0,0\"\u003eVariables Memory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,1,0\"\u003e2 MB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,11,0,0\"\u003eSupply Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,11,1,0\"\u003e20.4-28.8 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,12,0,0\"\u003eCommunication Ports\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,12,1,0\"\u003eEtherCAT Master, EtherNet\/IP, Ethernet TCP\/IP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eEtherNet\/IP \u0026amp; Backplane Bus Performance\u003c\/h3\u003e\n\u003cp data-path-to-node=\"10\"\u003eThe NX1P processor implements deterministic network switching over EtherCAT to manage distributed servo axes and remote I\/O modules with minimal jitter. Internal CPU backplane bus communication velocity guarantees rapid data interchange between the primary processor core and adjacent NX-series expansion I\/O units. Deterministic network packet handling on the EtherNet\/IP channel enables concurrent enterprise data connectivity without degrading real-time control task execution loops. High-density I\/O scaling is achieved through expansion bus couplers, while local firmware flash compatibility maintains version integrity across multi-axis motion profile libraries.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"11\"\u003eLogistics \u0026amp; Package Contents\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e1x Omron NX1P2-1140DT1 Sysmac CPU Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e1x Removable Terminal Block Set for DC Power and Direct I\/O Wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e1x End Cover Unit (NX-END02)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e1x Hardware Installation Sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003eMechanical Mounting \u0026amp; Wiring Protocol\u003c\/h3\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eDIN-Rail Attachment\u003c\/b\u003e: Mount the CPU vertically onto a standard 35 mm DIN rail (TH35-7.5\/TH35-15). Secure both ends with DIN rail stop brackets to prevent lateral displacement under industrial vibration profiles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eShielding \u0026amp; Grounding\u003c\/b\u003e: Connect the functional ground terminal (100 ohms or less) directly to an independent earth bus using a minimum 2.0 mm2 conductor wire to suppress electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eConductor Separation\u003c\/b\u003e: Route high-voltage power lines and motor drive cables in separate ducting at least 100 mm away from the EtherCAT and Ethernet communication wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cb data-path-to-node=\"14,3,0\" data-index-in-node=\"0\"\u003eTerminal Wiring\u003c\/b\u003e: Use ferruled stranded copper conductors rated for 75 deg C or higher when wiring the push-in Plus terminal block to maintain vibration-resistant electrical contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"15\"\u003eSystem Diagnostic FAQ\u003c\/h3\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003eHow does the primary task cycle time impact motion execution?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003eThe 2 ms primary cycle time locks the execution period for sequence programming and motion profiles, ensuring deterministic timing for axis positioning and sensor sampling routines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,1,0\"\u003eWhat voltage range is tolerated on the primary power terminals?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,1,0\"\u003eThe CPU accepts an input supply range of 20.4 VDC to 28.8 VDC. Supply excursions outside this boundary trigger internal power supply brownout protection and halt CPU execution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,2,0\"\u003eCan NX-series I\/O units be attached directly to the CPU base?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,2,0\"\u003eYes, NX-series digital, analog, and communication I\/O modules snap directly onto the right side of the NX1P CPU backplane bus interface without requiring intermediate cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,3,0\"\u003eDoes the EtherCAT master port support third-party fieldbus devices?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,3,0\"\u003eThe EtherCAT port supports standard EtherCAT Slave Information (ESI) files, allowing integration of third-party servo drives, distributed I\/O islands, and sensor blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,4,0\"\u003eWhat happens if an EtherCAT network cable is disconnected during operation?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,4,0\"\u003eThe CPU registers a communication link error, retains safe state configuration on local outputs, and continues executing local non-motion logic tasks unimpacted by the lost fieldbus node.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,5,0\"\u003eIs battery backup required to retain program memory during power outages?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,5,0\"\u003eNo, user program memory and non-volatile system variables are saved to internal non-volatile flash memory, eliminating the requirement for a continuous battery backup power source.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,6,0\"\u003eHow are the transistor PNP outputs protected against short circuits?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,6,0\"\u003eInternal overcurrent protection circuitry limits output current when an external load short occurs, toggling system diagnostic flags to alert the supervisory software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,7,0\"\u003eWhat wire gauge range is supported by the integrated push-in terminal block?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,7,0\"\u003eThe spring-cage push-in terminal blocks accommodate solid or ferruled flexible copper conductors ranging from 0.14 mm2 to 1.5 mm2 (AWG 28 to AWG 16).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306659266733,"sku":"NX1P2-1140DT1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/nx1p2-1140dt1-1_1.jpg?v=1790393761","url":"https:\/\/www.maxwellplc.com\/ru\/products\/nx1p2-1140dt1-omron-sysmac-nx1p-cpu","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}