{"product_id":"nx102-9000-omron-sysmac-nx1-modular-cpu","title":"NX102-9000 Omron Sysmac NX1 Modular CPU","description":"\u003cp\u003eThe \u003cstrong\u003eOmron NX102-9000\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNX102-9000\u003c\/strong\u003e Modular CPU, operates as a dedicated hardware component for multi-axis position control, sequence execution, and OPC-UA data bridging within Sysmac Sysmac NX1 platform architectures.\u003c\/p\u003e\n\u003ch3\u003eSystem Model Nomenclature\u003c\/h3\u003e\n\u003cp\u003eThe hardware part number structure designates core processing parameters:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNX102\u003c\/strong\u003e: Compact Sysmac CPU controller hardware platform with integrated EtherCAT and EtherNet\/IP bus interfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e9000\u003c\/strong\u003e: Standard database\/OPC-UA network integration feature set without safety control extensions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; Electrical Performance Parameters\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX102-9000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.580 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2.000 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Dimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e10.00 cm x 6.60 cm x 10.00 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e18.00 cm x 12.00 cm x 15.00 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e12.20 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Functionality\u003c\/td\u003e\n\u003ctd\u003eOPC-UA, Position control, Sequence control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Memory\u003c\/td\u003e\n\u003ctd\u003e5 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVariables Memory\u003c\/td\u003e\n\u003ctd\u003e33.5 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-Board Communication Ports\u003c\/td\u003e\n\u003ctd\u003eEtherCAT Master, EtherNet\/IP, Ethernet TCP\/IP, USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Serial Options\u003c\/td\u003e\n\u003ctd\u003eSerial RS-232C, Serial RS-422, Serial RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Remote I\/O Nodes\u003c\/td\u003e\n\u003ctd\u003e64 nodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal I\/O Bus Interface\u003c\/td\u003e\n\u003ctd\u003eNX I\/O Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Local Expansion Units\u003c\/td\u003e\n\u003ctd\u003e32 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Execution \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe CPU core coordinates high-speed EtherCAT motion axes alongside EtherNet\/IP deterministic networks, maintaining microsecond-level synchronization across distributed servo drives. Backplane bus communication velocity allows up to 32 local NX I\/O modules to update in real time while maintaining firmware flash compatibility and program execution consistency under dense I\/O density scaling profiles.\u003c\/p\u003e\n\u003ch3\u003ePackage \u0026amp; Component Listing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron NX102-9000 Sysmac NX1 Modular CPU Unit\u003c\/li\u003e\n\u003cli\u003e1 x End cover unit (NX-END02)\u003c\/li\u003e\n\u003cli\u003e1 x Power supply terminal connector block\u003c\/li\u003e\n\u003cli\u003e1 x Installation guide sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation \u0026amp; Enclosure Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the controller vertically onto a standard 35 mm DIN rail inside an IP54-rated industrial control enclosure.\u003c\/li\u003e\n\u003cli\u003eEnsure a minimum vertical clearance of 30 mm above and below the housing for proper convection cooling.\u003c\/li\u003e\n\u003cli\u003eTerminate the 24 VDC power supply wiring using 16 AWG conductors with crimped ferrules into the removable terminal block.\u003c\/li\u003e\n\u003cli\u003eConnect the protective earth (PE) terminal directly to the enclosure backplate ground copper bus.\u003c\/li\u003e\n\u003cli\u003eSnap local NX series I\/O modules sequentially onto the right side of the CPU before attaching the end cover.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Support FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the NX102-9000 CPU support local hot-swapping of expansion modules?\u003c\/p\u003e\n\u003cp\u003eNo, local expansion modules on the NX I\/O Bus must not be removed or added while backplane power is applied to the CPU.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum number of EtherCAT remote nodes supported by this processor?\u003c\/p\u003e\n\u003cp\u003eThe integrated EtherCAT master interface supports up to 64 remote I\/O and drive nodes in a single network topology.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is program memory retained during power outages?\u003c\/p\u003e\n\u003cp\u003eThe processor uses non-volatile flash memory to preserve sequence programs and non-volatile variables without a battery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat serial communication options can be integrated with this processor?\u003c\/p\u003e\n\u003cp\u003eOption boards can be installed on the front slot to add RS-232C, RS-422, or RS-485 serial communication capability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many local expansion units can be attached directly to the CPU backplane?\u003c\/p\u003e\n\u003cp\u003eUp to 32 NX-Series digital, analog, or function modules can be attached directly to the local CPU backplane bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum total variables memory allocated in this CPU?\u003c\/p\u003e\n\u003cp\u003eThe hardware provides 33.5 MB of dedicated variables memory alongside 5 MB of non-volatile program memory.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs OPC-UA server functionality natively supported on the embedded network interfaces?\u003c\/p\u003e\n\u003cp\u003eYes, the CPU incorporates native OPC-UA server functionality over its primary Ethernet interface for secure host communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the proper procedure for grounding the CPU chassis?\u003c\/p\u003e\n\u003cp\u003eConnect a low-impedance ground conductor from the CPU ground terminal directly to the panel backplate DIN rail ground strap.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306661298349,"sku":"NX102-9000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/nx102-9000.jpg?v=1790689715","url":"https:\/\/www.maxwellplc.com\/ru\/products\/nx102-9000-omron-sysmac-nx1-modular-cpu","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}