{"product_id":"nx102-1120-omron-sysmac-nx1-modular-cpu-sysmac-nx-series","title":"NX102-1120 Omron Sysmac NX1 Modular CPU Sysmac NX Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron NX102-1120\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNX102-1120\u003c\/strong\u003e Sysmac NX1 Modular CPU, operates as a dedicated hardware component for real-time motion control and database connectivity within Sysmac automation architectures. The controller executes sequence and motion tasks on a 1 ms primary task cycle, managing up to 4 synchronous axes and up to 15 total axes (including virtual). Featuring 5 MB program memory, 33.5 MB variables memory, and onboard OPC-UA and EtherCAT Master interfaces, it coordinates data transfer across local NX I\/O expansion racks and up to 64 remote I\/O nodes.\u003c\/p\u003e\n\u003ch3\u003eIdentification \u0026amp; Architecture Nomenclature\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNX102\u003c\/strong\u003e: Sysmac compact controller series with dual EtherNet\/IP and database functionality.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1120\u003c\/strong\u003e: Performance tier specifying 4-axis motion control and integrated OPC-UA server capability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance \u0026amp; System Parameters\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX102-1120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e10 x 6.6 x 10 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Task Cycle Time\u003c\/td\u003e\n\u003ctd\u003e1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Memory\u003c\/td\u003e\n\u003ctd\u003e5 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVariables Memory\u003c\/td\u003e\n\u003ctd\u003e33.5 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSynchronous Axes\u003c\/td\u003e\n\u003ctd\u003e4 max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePTP Axes\u003c\/td\u003e\n\u003ctd\u003e4 max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Axes (incl. Virtual)\u003c\/td\u003e\n\u003ctd\u003e15 max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnboard Communication\u003c\/td\u003e\n\u003ctd\u003eEtherCAT Master, EtherNet\/IP, Ethernet TCP\/IP, USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eSerial RS-232C, Serial RS-422, Serial RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Capacity\u003c\/td\u003e\n\u003ctd\u003e32 units max (NX I\/O Bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e64 nodes max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBus Communication Velocity \u0026amp; Local Scaling\u003c\/h3\u003e\n\u003cp\u003eThe CPU coordinates real-time motion profiles across EtherCAT fieldbus topologies while maintaining deterministic communications over EtherNet\/IP trunklines. High backplane bus communication velocity allows seamless internal data transfer to local expansion modules without compromising 1 ms cycle timing. Scalable I\/O density scaling supports up to 32 slice modules per rack, while non-volatile memory maintains firmware flash compatibility across all connected bus nodes.\u003c\/p\u003e\n\u003ch3\u003eScope of Delivery\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron NX102-1120 Modular CPU Unit\u003c\/li\u003e\n\u003cli\u003e1 x Bus End Cover\u003c\/li\u003e\n\u003cli\u003e1 x Installation Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWiring \u0026amp; Physical Mounting Directives\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Assembly\u003c\/strong\u003e: Hook the upper latch of the unit onto a standard 35 mm DIN rail and push firmly until the lower locking tab engages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNX Bus Expansion\u003c\/strong\u003e: Slide local NX I\/O slice modules laterally into side connectors until the locking mechanisms click into position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding \u0026amp; Grounding\u003c\/strong\u003e: Wire the functional ground terminal to the main panel ground bar using a short, low-impedance copper conductor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEtherCAT Network Cabling\u003c\/strong\u003e: Connect double-shielded Category 5e STP cables to the EtherCAT master port to prevent electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Termination\u003c\/strong\u003e: Install the included bus end cover on the rightmost NX I\/O module to complete the internal backplane logic circuit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Knowledge Base\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the NX102-1120 CPU support live hot-swapping of local NX I\/O slice modules?\u003c\/p\u003e\n\u003cp\u003eNo. Main power to the CPU unit and I\/O bus must be turned off before replacing local slice modules to prevent module damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat limits apply to the maximum number of synchronous motion axes?\u003c\/p\u003e\n\u003cp\u003eThe controller supports a maximum of 4 synchronous motion axes and 4 PTP axes within its 15 total axis memory limit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are database connectivity features handled during network disconnects?\u003c\/p\u003e\n\u003cp\u003eSpooling memory buffers hold SQL transactions internally in variables memory until network communication to the server resumes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat cable specification is required for the integrated EtherCAT Master port?\u003c\/p\u003e\n\u003cp\u003eUse Category 5e or higher aluminum tape and braided double-shielded twisted-pair (STP) Ethernet cables with shielded RJ45 connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the NX bus require a physical termination component at the end of the rack?\u003c\/p\u003e\n\u003cp\u003eYes. The provided bus end cover must be attached to the right edge of the last NX I\/O module for the backplane to function.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is firmware flash compatibility verified across connected field devices?\u003c\/p\u003e\n\u003cp\u003eFirmware compatibility is managed via Sysmac Studio, which checks CPU and remote node revision levels prior to code deployment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum number of local expansion modules supported on the CPU backplane?\u003c\/p\u003e\n\u003cp\u003eThe CPU backplane supports up to 32 local NX I\/O expansion units connected directly alongside the main processor module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat communication protocols run concurrently over the onboard Ethernet ports?\u003c\/p\u003e\n\u003cp\u003eThe onboard ports run OPC-UA server communications, EtherNet\/IP explicit\/implicit messaging, and standard TCP\/IP sockets simultaneously.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306667622573,"sku":"NX102-1120","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/NX102-1120.jpg?v=1790222010","url":"https:\/\/www.maxwellplc.com\/ru\/products\/nx102-1120-omron-sysmac-nx1-modular-cpu-sysmac-nx-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}