{"product_id":"nx-ts3201-omron-temperature-input-unit-sysmac-nx-series","title":"NX-TS3201 Omron Temperature Input Unit Sysmac NX Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron NX-TS3201\u003c\/strong\u003e serves as the primary \u003cstrong\u003eNX-TS3201\u003c\/strong\u003e Temperature Input Unit utilized to execute multi-channel RTD signal processing across Sysmac NX Series platforms. Equipped with 4 input points for three-wire Pt100 and Pt1000 sensors, it operates at a conversion time of 250 ms per unit. The module incorporates optical isolation between field circuits and the internal bus, transferring process data via Free-Run refreshing.\u003c\/p\u003e\n\u003ch3\u003ePart Number Code Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNX\u003c\/strong\u003e: Sysmac modular slice I\/O platform prefix.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTS\u003c\/strong\u003e: Temperature input functional unit designation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3\u003c\/strong\u003e: High-density 4-point input channel capacity index.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2\u003c\/strong\u003e: Resistance thermometer (RTD) circuit interface type.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e01\u003c\/strong\u003e: Standard performance conversion rating (250 ms\/unit conversion speed).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Hardware Parameters\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX-TS3201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e2.4 x 7.1 x 10.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.95 W max (NX bus power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e4 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd\u003ePt100 (three-wire), Pt1000 (three-wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Time\u003c\/td\u003e\n\u003ctd\u003e250 ms\/unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefreshing Method\u003c\/td\u003e\n\u003ctd\u003eFree-Run refreshing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarm-Up Period\u003c\/td\u003e\n\u003ctd\u003e10 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Method\u003c\/td\u003e\n\u003ctd\u003ePower = Transformer, Signal = Photocoupler (Input to NX bus and channel-to-channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e20 Mohm min between isolated circuits (at 100 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003eScrewless clamping terminal block (16 terminals x 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Bus \u0026amp; Module Density\u003c\/h3\u003e\n\u003cp\u003eDesigned for integration into Profinet \/ EtherNet\/IP deterministic networks, the module communicates across the internal NX backplane bus using high-speed cyclic sampling. High backplane bus communication velocity allows all 4 RTD input values to be processed simultaneously without impacting controller cycle time. The platform maintains strict firmware flash compatibility across all Sysmac couplers, enabling optimal I\/O density scaling in distributed automation systems.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information \u0026amp; Package Scope\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron NX-TS3201 Temperature Input Unit\u003c\/li\u003e\n\u003cli\u003e2 x Screwless Clamping Terminal Blocks (16 Terminals Each)\u003c\/li\u003e\n\u003cli\u003e1 x Hardware Manual \u0026amp; Installation Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Mounting \u0026amp; Field Wiring Rules\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting\u003c\/strong\u003e: Align top housing slots with a 35 mm DIN rail and pivot the unit backward until the lower DIN clip locks firmly into place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTD Sensor Connection\u003c\/strong\u003e: Connect three-wire Pt100 or Pt1000 sensors to the screwless clamping terminal block, ensuring equal lead wire resistance across all terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-Up Phase\u003c\/strong\u003e: Allow a 10-minute warm-up period after power application to ensure internal measurement circuits stabilize before collecting process values.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Mating\u003c\/strong\u003e: Slide adjacent NX modules together horizontally along the DIN rail until side bus connectors mesh securely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise Suppression\u003c\/strong\u003e: Route RTD wiring away from high-voltage motor power leads and terminate overall cable shields to the main panel functional ground.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping supported for the NX-TS3201 on an energized backplane?\u003c\/p\u003e\n\u003cp\u003eNo. You must disconnect main CPU backplane power and sensor excitation power prior to inserting or removing the unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhich RTD element types can be wired to the 4 input channels?\u003c\/p\u003e\n\u003cp\u003eThe module supports standard three-wire Pt100 and three-wire Pt1000 resistance temperature detectors across all 4 input points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the required warm-up duration after initial power-up?\u003c\/p\u003e\n\u003cp\u003eA warm-up period of at least 10 minutes is required for internal voltage references and A\/D conversion circuits to reach thermal stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does Free-Run refreshing execute temperature sampling?\u003c\/p\u003e\n\u003cp\u003eFree-Run refreshing continuously executes analog-to-digital conversions independently of the controller's main task cycle time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat isolation scheme is implemented between individual input channels?\u003c\/p\u003e\n\u003cp\u003eChannel-to-channel isolation utilizes internal power transformers and signal photocouplers to prevent ground loops and inter-channel noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat terminal connection system is provided with the module?\u003c\/p\u003e\n\u003cp\u003eField signals terminate via two front-mounted screwless clamping terminal blocks containing 16 connection points each.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does backplane communication velocity affect temperature updates?\u003c\/p\u003e\n\u003cp\u003eHigh backplane velocity ensures that converted RTD data frames stream to the head coupler without network transmission lag.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is firmware flash compatibility verified during module replacement?\u003c\/p\u003e\n\u003cp\u003eSysmac Studio validates hardware revision parameters against project configuration profiles before downloading firmware parameters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306670506157,"sku":"NX-TS3201","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/NX-TS3201_2.jpg?v=1790221026","url":"https:\/\/www.maxwellplc.com\/ru\/products\/nx-ts3201-omron-temperature-input-unit-sysmac-nx-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}