{"product_id":"nx-ts3102-omron-temperature-input-unit-sysmac-nx-series","title":"NX-TS3102 Omron Temperature Input Unit Sysmac NX Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron NX-TS3102\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNX-TS3102\u003c\/strong\u003e Temperature Input Unit, operates as a dedicated hardware component for multi-channel thermocouple signal acquisition within Sysmac NX automation networks. It provides 4 isolated temperature input points supporting K, J, T, E, L, U, N, R, S, WRe5-26, and PLII sensor types at a conversion speed of 10 ms per unit. Interfacing across the NX backplane via Free-Run refreshing, the unit delivers 0.01 deg C resolution with digital isolator channel separation.\u003c\/p\u003e\n\u003ch3\u003eModel Numbering \u0026amp; Functional Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNX\u003c\/strong\u003e: Sysmac modular slice I\/O series hardware platform designation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTS\u003c\/strong\u003e: Temperature input function unit classification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3\u003c\/strong\u003e: 4-channel temperature point capacity index.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1\u003c\/strong\u003e: Thermocouple sensor input circuit type.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e02\u003c\/strong\u003e: Advanced resolution specification (0.01 deg C max, 10 ms\/unit conversion speed).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance Parameters\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX-TS3102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e2.4 x 7.1 x 10.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.55 W max (CPU \/ Comm Unit connection) \/ 1.10 W max (Coupler connection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e4 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Compatibility\u003c\/td\u003e\n\u003ctd\u003eThermocouple types K, J, T, E, L, U, N, R, S, WRe5-26, PLII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 deg C max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Time\u003c\/td\u003e\n\u003ctd\u003e10 ms\/unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e20 kohm min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisconnection Detection\u003c\/td\u003e\n\u003ctd\u003eApprox 0.1 uA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute Maximum Rating\u003c\/td\u003e\n\u003ctd\u003e+\/-130 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Scheme\u003c\/td\u003e\n\u003ctd\u003eTransformer (Power) \/ Digital Isolator (Signal) between inputs and NX bus \/ between channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e20 Mohm min between isolated circuits (at 100 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e510 VAC between isolated circuits for 1 minute (5 mA max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefreshing Method\u003c\/td\u003e\n\u003ctd\u003eFree-Run refreshing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrewless clamping terminal block (16 terminals x 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Communication \u0026amp; Density Scaling\u003c\/h3\u003e\n\u003cp\u003eOperating within Profinet \/ EtherNet\/IP deterministic networks, the unit processes digitized temperature measurements across the internal NX backplane bus. High backplane bus communication velocity allows rapid cyclic data transfers to the head controller without introducing network frame delays. The hardware architecture preserves firmware flash compatibility across all Sysmac couplers, providing seamless I\/O density scaling inside space-constrained control enclosures.\u003c\/p\u003e\n\u003ch3\u003eStandard Commercial Deliverables\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron NX-TS3102 Temperature Input Unit\u003c\/li\u003e\n\u003cli\u003e2 x Screwless Clamping Terminal Blocks (16 Terminals Each)\u003c\/li\u003e\n\u003cli\u003e1 x Technical Instruction Leaflet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Wiring \u0026amp; Physical Installation Directives\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting\u003c\/strong\u003e: Hook the top guide notch onto a standard 35 mm DIN rail and press the module backward until the lower locking lever snaps into place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermocouple Wiring\u003c\/strong\u003e: Insert thermocouple extension wires directly into the screwless clamping terminal slots, ensuring correct polarity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-Up Allowance\u003c\/strong\u003e: Allow a 45-minute warm-up period after power-on to stabilize internal cold junction compensation circuitry before reading temperature values.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Assembly\u003c\/strong\u003e: Slide the unit laterally along the DIN rail to mate internal bus connectors securely with adjacent NX modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Shielding\u003c\/strong\u003e: Ground thermocouple shielding wires directly to the panel functional ground terminal to prevent external high-frequency interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIs live hot-swapping supported for the NX-TS3102 on an active NX bus rail?\u003c\/p\u003e\n\u003cp\u003eNo. Main power to the CPU or coupler unit and external circuit power must be isolated prior to removing or mounting the module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat sensor types are supported by the 4 input channels?\u003c\/p\u003e\n\u003cp\u003eThe module accepts thermocouple types K, J, T, E, L, U, N, R, S, WRe5-26, and PLII with configurable scaling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow long is the required warm-up time after powering up the unit?\u003c\/p\u003e\n\u003cp\u003eA minimum warm-up period of 45 minutes is required for cold junction compensation circuits to reach thermal stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat isolation method is implemented between individual input channels?\u003c\/p\u003e\n\u003cp\u003ePower isolation uses internal transformers, while signal pathways use digital isolators between channels and the backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the input disconnection detection current on thermocouple loops?\u003c\/p\u003e\n\u003cp\u003eThe open-circuit wire break detection circuit outputs a small burnout test current of approximately 0.1 uA across the terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does Free-Run refreshing operate on the temperature input module?\u003c\/p\u003e\n\u003cp\u003eFree-Run refreshing continuously executes analog-to-digital conversions asynchronously from the main controller task execution cycle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the input voltage exceeds the absolute maximum rating?\u003c\/p\u003e\n\u003cp\u003eVoltages exceeding the +\/-130 mV absolute maximum rating will damage internal analog front-end switching components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is firmware flash compatibility maintained across different coupler units?\u003c\/p\u003e\n\u003cp\u003eSysmac Studio automatically checks module revision numbers against system profiles during project configuration to match firmware rules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306669621421,"sku":"NX-TS3102","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/NX-TS3102_1.jpg?v=1790221454","url":"https:\/\/www.maxwellplc.com\/ru\/products\/nx-ts3102-omron-temperature-input-unit-sysmac-nx-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}