{"product_id":"nx-od6256-5-omron-digital-output-unit-nx-series","title":"NX-OD6256-5 Omron Digital Output Unit NX Series","description":"\u003cp data-path-to-node=\"4\"\u003eThe \u003cb data-path-to-node=\"4\" data-index-in-node=\"4\"\u003eOmron NX-OD6256-5\u003c\/b\u003e, also cataloged as the \u003cb data-path-to-node=\"4\" data-index-in-node=\"45\"\u003eNX-OD6256\u003c\/b\u003e Digital I\/O Unit, operates as a dedicated hardware component for high-density 24 VDC switching and load drive execution within Sysmac EtherCAT and EtherNet\/IP networks.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"5\"\u003eInternal Part Designation Scheme\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eNX\u003c\/b\u003e: Slice I\/O modular platform family.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eOD\u003c\/b\u003e: Digital transistor output function group.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003e6256\u003c\/b\u003e: High-density configuration with 32 transistor output channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003e5\u003c\/b\u003e: PNP logic output type with 1-wire connection interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eParameter Ratings \u0026amp; Performance Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"8\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,1,1,0\"\u003eNX-OD6256-5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,2,1,0\"\u003eOmron\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,0,0\"\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,3,1,0\"\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,0,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,4,1,0\"\u003e0.095 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,0,0\"\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,5,1,0\"\u003e8.95 cm x 3.0 cm x 10.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,0,0\"\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,6,1,0\"\u003e0 to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,0,0\"\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,7,1,0\"\u003eNot specified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,0,0\"\u003eDigital Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,8,1,0\"\u003eNone (0 inputs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,0,0\"\u003eDigital Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,9,1,0\"\u003e32 PNP transistor outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,0,0\"\u003ePermitted Output Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,10,1,0\"\u003e20.4 to 28.8 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,11,0,0\"\u003eMax Output Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,11,1,0\"\u003e0.5 A per point\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,12,0,0\"\u003eSignal Processing\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,12,1,0\"\u003eFree running, Standard speed, Synchronous\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,13,0,0\"\u003ePropagation Delay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,13,1,0\"\u003eOFF to ON: 0.5 ms, ON to OFF: 1.0 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,14,0,0\"\u003eTerminal Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"8,14,1,0\"\u003e1-wire method\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eSynchronous Backplane Bus \u0026amp; High-Density Execution\u003c\/h3\u003e\n\u003cp data-path-to-node=\"10\"\u003eThe module interfaces directly with the internal NX bus to achieve deterministic signal processing synchronized with the CPU primary task period. High backplane bus communication velocity supports cycle-accurate output refreshes across all 32 PNP transistor channels simultaneously. Embedded firmware flash compatibility maintains consistent timing profiles across system updates, providing scalable I\/O density scaling while preserving isolation between logic and field power domains.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"11\"\u003eShipment Box Contents\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e1 x Omron NX-OD6256-5 Digital Output Slice Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e1 x Terminal Block Connector Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e1 x Module Installation Sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003ePanel Installation \u0026amp; Field Wiring Protocol\u003c\/h3\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eSlice Assembly\u003c\/b\u003e: Align the side hooks of the NX module with the adjacent CPU or EtherCAT Coupler unit and slide until the internal bus connectors lock into engagement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003e1-Wire Connection\u003c\/b\u003e: Wire 24 VDC actuators directly to individual output terminals using 1-wire topology, connecting common reference lines to dedicated IO power distribution terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eConductor Specification\u003c\/b\u003e: Insert ferruled solid or stranded copper wires ranging from AWG 24 to AWG 16 into the push-in terminal slots for gas-tight contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cb data-path-to-node=\"14,3,0\" data-index-in-node=\"0\"\u003eShield Grounding\u003c\/b\u003e: Keep low-voltage output cables physically separated from motor inverter leads and AC supply lines to prevent inductive noise pickup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"15\"\u003eMaintenance \u0026amp; Diagnostic FAQ\u003c\/h3\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003eWhat is the response delay time for the output channels?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003eThe hardware propagation time measures 0.5 ms maximum for OFF-to-ON state switching and 1.0 ms maximum for ON-to-OFF state switching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,1,0\"\u003eDoes this module support hot-swapping on an active EtherCAT bus coupler?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,1,0\"\u003eNo, removing or inserting the module requires powering down the local NX bus segment to prevent backplane communication errors or hardware damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,2,0\"\u003eHow are output loads powered across the 32 channels?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,2,0\"\u003eField power is drawn from the I\/O power supply terminals routed through the NX bus or an auxiliary power supply unit, operating between 20.4 and 28.8 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,3,0\"\u003eCan the outputs be synchronized with the master PLC execution cycle?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,3,0\"\u003eYes, the module supports synchronous I\/O refreshing, locking state updates directly to the EtherCAT distributed clock and CPU primary task period.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,4,0\"\u003eWhat happens if an individual output channel experiences an overcurrent event?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,4,0\"\u003eInternal protection circuits trip to isolate the fault, preventing damage to the internal transistor switches and reporting diagnostic flags to the CPU.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,5,0\"\u003eIs external field power required for the PNP output drive circuit?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,5,0\"\u003eYes, 24 VDC field supply must be supplied via the NX bus power distribution rail or an additional NX-PF feed unit to power external loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,6,0\"\u003eWhat wire terminal technology is used on the removable connector block?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,6,0\"\u003eThe unit utilizes Push-In Plus spring-cage terminals, allowing tool-less direct wire insertion for vibration-resistant electrical connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,7,0\"\u003eCan 2-wire or 3-wire field devices connect directly to this module?\u003c\/p\u003e\n\u003cp data-path-to-node=\"16,7,0\"\u003eBecause this module uses 1-wire connections, 2-wire and 3-wire loads require external common terminal blocks or additional power distribution units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306653892781,"sku":"NX-OD6256-5","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/nx-od6256-5_3_5.jpg?v=1790392973","url":"https:\/\/www.maxwellplc.com\/ru\/products\/nx-od6256-5-omron-digital-output-unit-nx-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}