{"product_id":"nx-da3203-omron-analog-output-unit-nx-series","title":"NX-DA3203 Omron Analog Output Unit NX Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron NX-DA3203\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNX-DA32\u003c\/strong\u003e Analog Output Unit, operates as a dedicated hardware component for multi-channel current signal generation within Sysmac NX-series I\/O bus architectures.\u003c\/p\u003e\n\u003ch3\u003eModel Identification \u0026amp; Circuit Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNX\u003c\/strong\u003e: Specifies integration within the Omron NX I\/O system backplane architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDA\u003c\/strong\u003e: Identifies the analog output functional classification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3203\u003c\/strong\u003e: Indicates a 4-channel analog output configuration operating across a 4 to 20 mA current loop range with 1\/8000 resolution.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational Performance Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNX-DA3203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e70 g max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e12.0 cm x 3.0 cm x 10.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.85 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Points\u003c\/td\u003e\n\u003ctd\u003e4 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1\/8000 (0 to 8000 full scale)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.3% of full scale at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Time\u003c\/td\u003e\n\u003ctd\u003e250 us\/point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Refreshing Method\u003c\/td\u003e\n\u003ctd\u003eFree-Run refreshing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBus Communication \u0026amp; High-Density Scalability\u003c\/h3\u003e\n\u003cp\u003eThe analog output module executes real-time conversion cycles across all four channels, updating digital values into proportional 4 to 20 mA current outputs. Operating on high-speed backplane bus communication velocity protocols, the hardware supports high I\/O density scaling alongside Sysmac CPU units or EtherCAT Couplers. Internal firmware flash compatibility ensures synchronized register processing and output stability across multi-axis or multi-loop industrial control layouts.\u003c\/p\u003e\n\u003ch3\u003eShipping Package Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron NX-DA3203 Analog Output Module\u003c\/li\u003e\n\u003cli\u003e1 x 16-Pin Push-In Terminal Block\u003c\/li\u003e\n\u003cli\u003e1 x Installation Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet Installation \u0026amp; Field Wiring Rules\u003c\/h3\u003e\n\u003ch4\u003eRail Mounting Procedure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAlign the module side grooves with adjacent NX-series units on a standard 35 mm DIN rail.\u003c\/li\u003e\n\u003cli\u003ePress the unit backward until the bus connector latch snaps securely onto the backplane rail assembly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCurrent Loop Wiring Standards\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eStrip solid or ferruled conductor wires to 10 mm and insert them directly into the push-in screwless terminal block.\u003c\/li\u003e\n\u003cli\u003eKeep 4 to 20 mA analog output wiring routed away from AC power lines and high-voltage motor conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCable Shielding \u0026amp; Grounding\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUse shielded twisted-pair cables for all current output signals.\u003c\/li\u003e\n\u003cli\u003eConnect cable shielding to the functional earth terminal of the NX-series rack to block high-frequency noise.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat current output range is provided across the output channels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module provides four independent current output channels operating over a standard 4 to 20 mA current loop range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat digital resolution corresponds to the 4 to 20 mA output span?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module converts digital register values from 0 to 8000 (0 to 100%) with a digital resolution rating of 1\/8000.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the analog signal conversion speed per channel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInternal digital-to-analog conversion completes at a rated conversion speed of 250 us per output point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat overall signal conversion accuracy is maintained at ambient room temperature?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe overall output accuracy is +\/-0.3% of full scale at an operating ambient temperature of 25 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhich I\/O refreshing method is utilized by the NX-DA3203 module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit operates using Free-Run refreshing logic independently of the controller task cycle time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat terminal connection style is integrated into the front interface?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eField wiring connects through a removable 16-terminal push-in screwless clamping terminal block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat physical mass does the standalone module possess?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe standalone physical mass of the NX-DA3203 analog output module is 70 g max.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow are field current loops shielded against electromagnetic interference?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSignal lines require shielded twisted-pair cables grounded directly to the NX rack functional earth connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306678501549,"sku":"NX-DA3203","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/NX-DA3203_1.jpg?v=1789711939","url":"https:\/\/www.maxwellplc.com\/ru\/products\/nx-da3203-omron-analog-output-unit-nx-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}