{"product_id":"ns10-tv00b-v1-omron-programmable-terminal-ns-series","title":"NS10-TV00B-V1 Omron Programmable Terminal NS Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron NS10-TV00B-V1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNS10-TV00\u003c\/strong\u003e Programmable Terminal, operates as a dedicated hardware component for graphical process interface monitoring and register bit execution within Omron PLC networks.\u003c\/p\u003e\n\u003ch3\u003eNomenclature and Model Structure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNS10\u003c\/strong\u003e: Identifies the 10.4-inch display frame tier within the operator interface family.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTV\u003c\/strong\u003e: Specifies high-resolution TFT active-matrix color LCD panel hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e: Denotes standard dual serial interface configuration without factory integrated Ethernet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB\u003c\/strong\u003e: Designates black bezel panel housing finish.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eV1\u003c\/strong\u003e: Indicates System Version 1 hardware design revision with core system memory architecture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance Parameters\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNS10-TV00B-V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e300 mm x 240 mm x 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Device\u003c\/td\u003e\n\u003ctd\u003eTFT Color LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScreen Diagonal\u003c\/td\u003e\n\u003ctd\u003e10.4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e640 x 480 dots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Depth\u003c\/td\u003e\n\u003ctd\u003e256 colors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e22 W max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Bus and Firmware Management\u003c\/h3\u003e\n\u003cp\u003eSerial fieldbus communications utilize optimized protocol stacks to sustain high-frequency register polling across host controller memory areas. The hardware structure ensures high backplane bus communication velocity Licences and consistent data updates during heavy I\/O density scaling. Integrated boot logic maintains firmware flash compatibility, preventing system image corruption and enabling stable initialization following sudden plant power interruptions.\u003c\/p\u003e\n\u003ch3\u003ePackage Component List\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron NS10-TV00B-V1 Programmable Terminal\u003c\/li\u003e\n\u003cli\u003e1 x Power Input Terminal Connector Block\u003c\/li\u003e\n\u003cli\u003e6 x Mounting Brackets with Retaining Screws\u003c\/li\u003e\n\u003cli\u003e1 x Bezel Sealing Ring (Pre-mounted)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Wiring Protocol\u003c\/h3\u003e\n\u003ch4\u003eCutout and Convection Requirements\u003c\/h4\u003e\n\u003cp\u003ePrepare a rectangular panel door opening matching 10.4-inch enclosure dimensions. Maintain at least 100 mm clear perimeter space around top, bottom, and side ventilation slots to permit unobstructed upward natural air convection.\u003c\/p\u003e\n\u003ch4\u003eMechanical Clamp Mounting\u003c\/h4\u003e\n\u003cp\u003eEnsure the perimeter rubber sealing ring is undamaged and properly seated in the bezel groove. Insert the unit into the door cutout and tighten all retention brackets diagonally to maintain uniform seal compression for IP65 front panel sealing.\u003c\/p\u003e\n\u003ch4\u003ePower and Earth Grounding\u003c\/h4\u003e\n\u003cp\u003eWire a regulated 24 VDC power line using 1.5 mm2 (16 AWG) copper conductor. Connect the terminal Functional Ground (FG) lug directly to the main cabinet ground bar using the shortest possible low-impedance connection to prevent noise interference.\u003c\/p\u003e\n\u003ch3\u003eTechnical Questions \u0026amp; Answers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping the 24 VDC main power connector permitted during active operation?\u003c\/p\u003e\n\u003cp\u003eDisconnecting main 24 VDC power while active halts operational processing instantly and risks corrupting unwritten system data or internal SRAM alarm logs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat steps mitigate touch position offset or non-responsive touch entries?\u003c\/p\u003e\n\u003cp\u003eHigh-frequency electrical noise on DC supply rails or a disconnected FG ground wire causes touch controller drift. Verify clean 24 VDC power and low-impedance ground bonding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat thermal placement constraints govern vertical cabinet mounting?\u003c\/p\u003e\n\u003cp\u003eThe terminal must be oriented vertically within 30 deg of perpendicular. Horizontal or severely tilted mounting restricts vertical airflow, leading to internal heat accumulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat precautions must be enforced during system firmware updates?\u003c\/p\u003e\n\u003cp\u003eMaintain uninterrupted 24 VDC supply voltage throughout the write process. A power failure during flash memory updates corrupts bootloader sectors and renders the unit inoperable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are serial bus transmission timeout errors processed by internal logic?\u003c\/p\u003e\n\u003cp\u003eCommunication timeouts prompt visual error banners on screen. Retry attempt limits and response delay thresholds are fully adjustable within the internal system menu settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat routing practices protect serial links against electromagnetic noise?\u003c\/p\u003e\n\u003cp\u003eRoute communication cables inside dedicated grounded metal conduits, separated from high-voltage AC lines, variable frequency drives, and heavy inductive contactors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the internal lithium battery protect real-time system data?\u003c\/p\u003e\n\u003cp\u003eThe integrated lithium battery maintains real-time clock running states and preserves SRAM log registers whenever main external 24 VDC supply power is disconnected.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat inline circuit protection should be installed on the incoming DC lines?\u003c\/p\u003e\n\u003cp\u003eInstall a fast-acting 3 A inline fuse on the positive +24 VDC lead to protect internal power conversion circuits against overcurrent and supply surge conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306664444077,"sku":"NS10-TV00B-V1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/NS-5.jpg?v=1790141006","url":"https:\/\/www.maxwellplc.com\/ru\/products\/ns10-tv00b-v1-omron-programmable-terminal-ns-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}