NKAS11-12 ABB Bailey Infi 90 Analog Slave Termination Unit Cable
NKAS11-12 ABB Bailey Infi 90 Analog Slave Termination Unit Cable
ABB

NKAS11-12 ABB Bailey Infi 90 Analog Slave Termination Unit Cable

SKU: NKAS11-12
Categories : ABB
In Stock
  • Dimensions: 38.1 x 7.6 x 33.0 cm
  • Country of origin: Sweden
  • Payment: T/T, Western Union
  • Shipping port: Xiamen
1 years warranty
Delivery time: 3-7 business days
Free 30 days return

Help

If you have any questions, you are always welcome to contact us. We'll get back to you as soon as possible, withing 24 hours on weekdays.

Customer service

All questions about your order, return and delivery must be sent to our customer service team by e-mail at yourstore@yourdomain.com

Sale & Press

If you are interested in selling our products, need more information about our brand or wish to make a collaboration, please contact us at press@yourdomain.com

Configured for multi-channel analog signal routing and slave termination module interconnectivity in Bailey Infi 90 DCS racks, the ABB NKAS11-12 (NKAS11 Analog Slave Termination Unit Cable) provides direct physical/electrical execution. This multi-conductor cable assembly transfers low-level voltage and current loop signals between analog slave processing cards and field termination units, supporting continuous 300 V AC insulation integrity across 16-32 conductor pathways.

Cable Part Number & Assembly Breakdown

  • NKAS11: Base part designation for Bailey Infi 90 analog slave termination interconnect cables.
  • -12: Extended assembly length designator (12 ft nominal length specification / 12 in physical harness span).
  • Conductor Harness: Multi-conductor bundle incorporating 16-32 discrete 20-22 AWG copper lines rated for 300 V AC service.

Technical & Electrical Specifications

Parameter Specification
Model NKAS11-12
Brand ABB
Origin SWEDEN
Weight 1.6 kg
Shipping Dimensions 38.1 x 7.6 x 33.0 cm
Operating Temp -20 deg C to +80 deg C
Power Consumption Passive component (0 W)
Voltage Rating 300 V AC
Conductor Gauge 20-22 AWG
Number of Conductors 16-32 conductors
Storage Temperature -40 deg C to +85 deg C
Humidity 5-95% RH (non-condensing)
Tariff Code 8537101190

Deterministic IO Bus Routing & Signal Integrity

The NKAS11-12 assembly supports structured backplane bus communication velocity and I/O density scaling across Infi 90 analog expansion racks. Low-resistance 20-22 AWG copper conductors limit loop impedance and prevent channel crosstalk during multi-channel signal multiplexing. The assembly preserves precise analog-to-digital measurement accuracy and maintains firmware flash compatibility across connected slave modules during continuous online operations.

Package & Ordering Components

  • 1 x ABB NKAS11-12 Analog Slave Termination Unit Cable
  • Factory ESD protective polybag packaging

Cabinet Cable Installation Guidelines

  • Connector Engagement: Insert terminal connectors fully into mating module headers and tighten retaining screws to establish low-resistance electrical contacts.
  • Bend Radius Limits: Maintain a minimum static cable bend radius of 75 mm inside wireways to prevent conductor stress and insulation degradation.
  • Signal Cable Separation: Route the analog slave cable bundle at least 200 mm clear of AC power wiring and high-current relay circuits to mitigate noise coupling.
  • Strain Relief: Secure the cable harness to cabinet tie-down points within 100 mm of the connection header to eliminate mechanical pull on terminal pins.

Technical Support FAQ

  • What is the primary application of the NKAS11-12 cable assembly?

    It provides multi-channel analog signal connections between slave processing modules and field termination blocks in Infi 90 racks.

  • What voltage isolation rating applies to the individual conductors?

    Each conductor in the assembly features high-dielectric insulation rated for continuous operation at 300 V AC.

  • Can the cable assembly be disconnected while the host module is powered?

    Disconnecting live cables breaks analog loops, triggering open-circuit diagnostic alarms on active controller channels.

  • How does conductor resistance affect measurement accuracy across this cable?

    The 20-22 AWG wire gauge minimizes series loop resistance, preserving voltage drops and 4-20 mA calibration limits.

  • Does the NKAS11-12 require separate external shield grounding wires?

    Internal cable shields connect automatically to system chassis earth through dedicated ground pins on the header connector.

  • What is the ambient temperature threshold for installed cable runs?

    The physical cable assembly operates continuously in ambient field temperatures from -20 deg C up to +80 deg C.

  • How does the cable construction prevent internal signal crosstalk?

    Conductors are arranged in twisted pairs with overall shielding to isolate adjacent analog channels from mutual induction.

  • How should spare cable harness length be stored within marshalling racks?

    Coil excess cable in loose loops with a minimum diameter of 200 mm to preserve conductor insulation and shielding integrity.

Shipping & Returns

Shipping

  • Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
  • Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
  • Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
  • Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.

Returns

  • 30-Day Window: Request a return within 30 days of receipt for eligible items.
  • Condition: Items must be in their original, factory-sealed condition with all tags.
  • Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
  • Fast Refunds: Approved refunds are processed to your original payment method within 10 days.

Shipping & Returns

Shipping

  • Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
  • Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
  • Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
  • Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.

Returns

  • 30-Day Window: Request a return within 30 days of receipt for eligible items.
  • Condition: Items must be in their original, factory-sealed condition with all tags.
  • Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
  • Fast Refunds: Approved refunds are processed to your original payment method within 10 days.

Warranty

Warranty

  • 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
  • Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
  • Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
  • Peace of Mind: Long-term reliability support for all your mission-critical automation parts.

Warranty

Warranty

  • 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
  • Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
  • Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
  • Peace of Mind: Long-term reliability support for all your mission-critical automation parts.

Secure Payment

Secure Payment

  • Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
  • Local Friendly: RMB transfers are accepted if you have a local agent in China.
  • Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
  • Data Safety: All transactions are processed through encrypted and secure banking channels.


Secure Payment

Secure Payment

  • Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
  • Local Friendly: RMB transfers are accepted if you have a local agent in China.
  • Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
  • Data Safety: All transactions are processed through encrypted and secure banking channels.


You may also like

From our blog

Latest News and Insights

Predictive Maintenance Adoption Accelerates Across Oil and Gas Operations
Sep 13, 2026
MaxWell
Predictive Maintenance Adoption Accelerates Across Oil and Gas Operations
The oil and gas industry is accelerating adoption of predictive maintenance strategies, with over 60%...
Read More
Industrial Automation Sector Q2 2026 Financial Results Show Mixed Performance
Sep 13, 2026
MaxWell
Industrial Automation Sector Q2 2026 Financial Results Show Mixed Performance
Industrial automation companies reported mixed financial results for the second quarter of 2026, reflecting varying...
Read More
POWERCHINA Advances 1.8 GW Wind Power Portfolio to Support Egypt's Energy Transition
Sep 13, 2026
MaxWell
POWERCHINA Advances 1.8 GW Wind Power Portfolio to Support Egypt's Energy Transition
Power Construction Corporation of China is advancing a portfolio of wind power projects totaling more...
Read More
Siemens Industrial AI Strategy: From CES 2026 to Production Floor
Sep 12, 2026
MaxWell
Siemens Industrial AI Strategy: From CES 2026 to Production Floor
Siemens' industrial artificial intelligence strategy has evolved from concept demonstration to production deployment, marking a...
Read More
ABB Rotork Acquisition Analysis: Strategic Expansion in Flow Control
Sep 12, 2026
MaxWell
ABB Rotork Acquisition Analysis: Strategic Expansion in Flow Control
ABB's landmark $5.5 billion acquisition of Rotork represents a decisive move to strengthen its position...
Read More
Global Renewable Energy Trends 2026: IRENA Statistical Insights
Sep 11, 2026
MaxWell
Global Renewable Energy Trends 2026: IRENA Statistical Insights
The International Renewable Energy Agency's 2026 statistical report reveals accelerating momentum in global renewable energy...
Read More
ABB IP66/Type 4X Drives: Rugged Motor Control Solutions for Harsh Industrial Environments
Sep 11, 2026
MaxWell
ABB IP66/Type 4X Drives: Rugged Motor Control Solutions for Harsh Industrial Environments
ABB has expanded its motor control portfolio with the introduction of ACS580, ACH580, and ACQ580...
Read More
DCS Selection Guide: Matching Control Architecture to Process Requirements
Sep 11, 2026
Shopify API
DCS Selection Guide: Matching Control Architecture to Process Requirements
Selecting the appropriate distributed control system requires careful analysis of process characteristics, operational requirements, and...
Read More
Rockwell Automation TechConnectIQ: AI-Powered Support Reshapes Industrial Service Delivery
Sep 11, 2026
MaxWell
Rockwell Automation TechConnectIQ: AI-Powered Support Reshapes Industrial Service Delivery
Rockwell Automation has introduced a comprehensive suite of technology initiatives aimed at transforming how manufacturers...
Read More
Wind Farm SCADA Optimization: Maximizing Energy Yield Through Data Analytics
Sep 10, 2026
MaxWell
Wind Farm SCADA Optimization: Maximizing Energy Yield Through Data Analytics
Wind farm SCADA systems have evolved from simple monitoring tools into sophisticated data analytics platforms...
Read More