{"product_id":"nkas01-10-abb-analog-module-termination-cable-bailey-infi-90","title":"NKAS01-10 ABB Analog Module Termination Cable Bailey Infi 90","description":"\u003cp\u003eThe \u003cstrong\u003eABB NKAS01-10\u003c\/strong\u003e serves as the primary \u003cstrong\u003eNKAS01\u003c\/strong\u003e Analog Module Termination Cable utilized to execute point-to-point analog signal routing between I\/O cards and terminal units across Bailey Infi 90 platforms. It routes multi-channel low-voltage analog signals, providing multi-conductor physical interconnection rated for 300 V AC and up to 2 A per conductor without introducing channel cross-talk or measurement offset errors.\u003c\/p\u003e\n\u003ch3\u003eCable Assembly Designator \u0026amp; Subsystem Structure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNKAS01\u003c\/strong\u003e: Base part identifier for Bailey Infi 90 analog module terminal unit interconnect cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-10\u003c\/strong\u003e: Specific cable designator for pre-terminated field wiring interfacing (10 ft nominal \/ 10 in physical connection span rating).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Wiring\u003c\/strong\u003e: 20-22 AWG multi-conductor copper bundle with 300 V insulation rating and 80 deg C thermal barrier.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; Electrical Data\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNKAS01-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSWEDEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e27.9 x 7.6 x 30.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +80 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive cable (0 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e2 A per conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Gauge\u003c\/td\u003e\n\u003ctd\u003e20-22 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5-95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Integration \u0026amp; High-Density IO Scaling\u003c\/h3\u003e\n\u003cp\u003eThe NKAS01-10 cable maintains analog measurement precision across high-density I\/O density scaling configurations in Infi 90 racks. By ensuring consistent conductor resistance and low signal capacitance across all channels, it prevents voltage drop and loop noise that interfere with backplane bus communication velocity and analog-to-digital processing. The cable construction supports uninterrupted firmware flash compatibility during module hot-swaps, protecting internal multiplexing logic on host processing cards.\u003c\/p\u003e\n\u003ch3\u003eShipping Kit \u0026amp; Packaging Assembly\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB NKAS01-10 Analog Module Termination Cable\u003c\/li\u003e\n\u003cli\u003eProtective connector dust caps inside sealed polybag packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet Interconnect \u0026amp; Cable Handling Rules\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Latching\u003c\/strong\u003e: Fully engage and secure screw-locks on both cable header connectors to prevent pin contact resistance and intermittent analog input drops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRouting Isolation\u003c\/strong\u003e: Keep analog signal cable runs separate from high-current AC lines and inductive loads by at least 200 mm to avoid noise coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrain Relief\u003c\/strong\u003e: Fasten the cable assembly to internal cabinet tie-bars within 150 mm of the connection header to eliminate physical strain on terminal pins.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatic Bend Radius\u003c\/strong\u003e: Maintain a minimum static bend radius of 60 mm during installation inside wiring ducts to preserve conductor insulation and shield coverage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational FAQ \u0026amp; Technical Constraints\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum continuous current capacity per conductor on the NKAS01-10?\u003c\/p\u003e\n\u003cp\u003eEach conductor path within the cable assembly is rated to carry up to 2 A continuous current at 300 V AC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this termination cable be disconnected while the host analog module is powered?\u003c\/p\u003e\n\u003cp\u003eDisconnecting under power interrupts live 4-20 mA or voltage loops, causing open-circuit fault detection on controller channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does conductor gauge size affect signal loss across this cable assembly?\u003c\/p\u003e\n\u003cp\u003eThe 20-22 AWG conductors minimize series loop resistance, preserving instrument accuracy across 1-5 V or 4-20 mA signal ranges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat voltage isolation rating applies to the internal conductor insulation?\u003c\/p\u003e\n\u003cp\u003eThe wire insulation layer is factory tested and rated for continuous operation up to 300 V AC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the NKAS01-10 cable require external ground wire connections?\u003c\/p\u003e\n\u003cp\u003eThe cable shield grounds automatically through the mating header pin assignment on the termination module chassis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum operating ambient temperature for this cable assembly?\u003c\/p\u003e\n\u003cp\u003eThe cable insulation material is rated for continuous field exposure from -20 deg C up to +80 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does this cable prevent channel-to-channel cross-talk in analog loops?\u003c\/p\u003e\n\u003cp\u003eIndividually twisted conductor pairs and internal shielding isolate low-level analog signals from adjacent channel interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat maintenance check is recommended for aging cable installations?\u003c\/p\u003e\n\u003cp\u003eInspect terminal connector pin contacts for oxidation and measure pin-to-pin loop resistance to ensure values stay under 1 ohm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021105713325,"sku":"NKAS01-10","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-nkas01-15-termination-cable-xomi3o0syp5_f3e8f171-c467-49ea-a0e9-eebb80b8111d.jpg?v=1762942490","url":"https:\/\/www.maxwellplc.com\/ru\/products\/nkas01-10-abb-analog-module-termination-cable-bailey-infi-90","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}