{"product_id":"na5-12w101s-v1-omron-machine-interface-na5-v1-series","title":"NA5-12W101S-V1 Omron Machine Interface NA5-V1 Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron NA5-12W101S-V1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNA5-12W101S\u003c\/strong\u003e Machine Interface, operates as a dedicated hardware component for high-resolution human-machine interaction and data processing within Sysmac EtherNet\/IP deterministic networks.\u003c\/p\u003e\n\u003ch3\u003eModel Identification Matrix\u003c\/h3\u003e\n\u003cp\u003eThe part number structure defines physical display and communication interface variants across the NA5 platform:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNA5\u003c\/strong\u003e: Sysmac Series Programmable Terminal base designation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12W\u003c\/strong\u003e: 12.1-inch widescreen TFT LCD display panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e101\u003c\/strong\u003e: 1280 x 800 WXGA pixel resolution with 16.77 million color depth.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eS\u003c\/strong\u003e: Silver bezel enclosure frame.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eV1\u003c\/strong\u003e: Enhanced hardware revision with expanded memory and updated system firmware support.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational Hardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNA5-12W101S-V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e310 mm (W) x 220 mm (H) x 69 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e25 W max (24 VDC +\/- 15%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003e12.1-inch TFT LCD widescreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1280 x 800 pixels (WXGA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouch Panel\u003c\/td\u003e\n\u003ctd\u003eAnalog resistive touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interfaces\u003c\/td\u003e\n\u003ctd\u003e1 x RS-232C port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interfaces\u003c\/td\u003e\n\u003ctd\u003e2 x Ethernet ports (1000BASE-T \/ 100BASE-TX \/ 10BASE-T)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Interfaces\u003c\/td\u003e\n\u003ctd\u003e2 x USB 2.0 Host (Type A), 1 x USB 2.0 Slave (Type B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Expansion\u003c\/td\u003e\n\u003ctd\u003e1 x SD Card slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eNetwork Determinism \u0026amp; Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe NA5-12W101S-V1 routes high-density variable tags directly over EtherNet\/IP deterministic networks, maintaining sub-millisecond polling cycles synchronized with NJ\/NX series automation controllers. Built-in dual Ethernet ports enable physical separation between machine control loops and plant-wide IT networks without compromising processing speed. Onboard system memory maintains total firmware flash compatibility with Sysmac Studio project files, preventing runtime execution mismatches.\u003c\/p\u003e\n\u003ch3\u003eDeliverables \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron NA5-12W101S-V1 HMI Terminal\u003c\/li\u003e\n\u003cli\u003e1 x 3-pin DC Power Input Terminal Block Connector\u003c\/li\u003e\n\u003cli\u003e4 x Panel Mounting Brackets with Securing Screws\u003c\/li\u003e\n\u003cli\u003e1 x Instruction Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Mounting \u0026amp; Panel Integration Directives\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCut a clean rectangular opening in the control cabinet door according to the template dimensions of 291 mm (W) x 201 mm (H).\u003c\/li\u003e\n\u003cli\u003eInsert the unit through the front cutout, ensuring the integrated rubber panel gasket is positioned correctly to maintain IP65 surface seal.\u003c\/li\u003e\n\u003cli\u003eAttach the four supplied mounting brackets into the side housing slots and torque the retaining screws evenly to 0.5 to 0.6 N m.\u003c\/li\u003e\n\u003cli\u003eConnect the 24 VDC power lines using 1.25 to 2.0 mm2 (AWG 16 to 14) stranded copper wire, and verify functional panel ground bonding.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum clearance of 100 mm around all rear heatsink vents to prevent thermal buildup inside the panel enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Engineering Technical FAQs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the V1 suffix impact firmware flash compatibility in existing Sysmac Studio projects?\u003c\/p\u003e\n\u003cp\u003eThe V1 hardware revision natively accepts updated system firmware versions while maintaining full backward project file import compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the unit operate simultaneously across two independent physical Ethernet subnets?\u003c\/p\u003e\n\u003cp\u003eYes, the two built-in Ethernet ports feature independent MAC addresses for simultaneous connection to machine control networks and factory LANs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat input voltage limits apply to the terminal block power input?\u003c\/p\u003e\n\u003cp\u003eThe unit requires a nominal supply of 24 VDC, operating safely across a permissible input voltage range of 20.4 VDC to 27.6 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat type of touch detection mechanism is embedded on the front glass screen?\u003c\/p\u003e\n\u003cp\u003eThe front panel uses an analog resistive touch surface, supporting precise single-touch operation with bare fingers or gloved hands.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat functions do the dual USB Host Type-A interfaces perform during operation?\u003c\/p\u003e\n\u003cp\u003eUSB Type-A ports accept standard USB flash drives for screen capture export, user access logging, recipe file transfers, and alarm history storage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the NA5-12W101S-V1 support hot-swap battery replacement for internal real-time clock retention?\u003c\/p\u003e\n\u003cp\u003eThe internal backup battery can be replaced while main DC supply power remains energized without interrupting operational parameters or clock data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat IP ingress rating does the front surface maintain when panel-mounted?\u003c\/p\u003e\n\u003cp\u003eWhen installed with the supplied sealing gasket and properly torqued mounting brackets, the front surface satisfies IP65 oil-tight protection standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are variable tags mapped between the NJ\/NX PLC controller and the NA5 terminal?\u003c\/p\u003e\n\u003cp\u003eTags are imported directly from Sysmac Studio projects using shared variable names, eliminating manual memory address assignment tables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306592714925,"sku":"NA5-12W101S-V1","price":112.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/NA5-12W101S-V1.jpg?v=1790173698","url":"https:\/\/www.maxwellplc.com\/ru\/products\/na5-12w101s-v1-omron-machine-interface-na5-v1-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}