{"product_id":"kfd2-sld-ex1-13100-pepperl-fuchs-solenoid-driver-k-system","title":"KFD2-SLD-Ex1.13100 Pepperl+Fuchs Solenoid Driver K-System","description":"\u003cp\u003eThe \u003cstrong\u003ePepperl+Fuchs KFD2-SLD-Ex1.13100\u003c\/strong\u003e serves as the primary \u003cstrong\u003eKFD2-SLD\u003c\/strong\u003e Solenoid Driver utilized to execute intrinsically safe loop energization for field-mounted valves across intrinsic safety (Ex i) barriers platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Designation \u0026amp; Suffix Logic\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eKFD2\u003c\/strong\u003e: K-System standard housing designed for 35 mm DIN rail or Power Rail installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSLD\u003c\/strong\u003e: Solenoid driver function group delivering loop-powered or bus-powered drive current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEx1\u003c\/strong\u003e: Single-channel galvanically isolated intrinsically safe output circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e13100\u003c\/strong\u003e: Specific voltage\/current output characteristic profile (13 V DC output voltage limit at 100 mA current threshold).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCore Technical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKFD2-SLD-Ex1.13100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 150 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e20 mm x 119 mm x 115 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Circuit\u003c\/td\u003e\n\u003ctd\u003e19 to 30 VDC control signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003eMin. 13 VDC at 100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003eReinforced isolation according to EN 60079-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e1 single-channel isolated drive output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHazardous Area Barrier Integrity and Mechanical Stability\u003c\/h3\u003e\n\u003cp\u003eThe isolated driver channels preserve strict intrinsic safety (Ex i) barriers separation between safe-area logic controllers and hazardous area field actuators. Solid housing latches enforce high DIN-rail mounting stability under ambient mechanical stress, preventing earth loops while maintaining internal surge voltage protection limits and low protocol conversion latencies across field discrete actuation loops.\u003c\/p\u003e\n\u003ch3\u003ePackage Component Checklist\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Pepperl+Fuchs KFD2-SLD-Ex1.13100 Solenoid Driver Module\u003c\/li\u003e\n\u003cli\u003e1 x Blue Intrinsically Safe Output Terminal Connector\u003c\/li\u003e\n\u003cli\u003e1 x Black Control Side Logic Terminal Connector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation \u0026amp; Wiring Protocol\u003c\/h3\u003e\n\u003ch4\u003eModule Rail Placement\u003c\/h4\u003e\n\u003cp\u003eAttach the module vertically onto a standard 35 mm DIN rail or integrated Power Rail structure. Press down firmly until the locking spring latches engage with the rail profile.\u003c\/p\u003e\n\u003ch4\u003eSafe Area Control Signal Wiring\u003c\/h4\u003e\n\u003cp\u003eTerminate logic switching signals from the host controller at black terminals 7(+) and 8(-). Ensure drive signal levels strictly match the specified 24 VDC control threshold.\u003c\/p\u003e\n\u003ch4\u003eHazardous Field Actuator Connection\u003c\/h4\u003e\n\u003cp\u003eConnect field solenoid wires to blue terminals 1(+) and 2(-). Maintain physical routing separation between intrinsically safe field wiring and non-intrinsically safe power lines.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat maximum output drive current does the module supply to a field solenoid valve?\u003c\/p\u003e\n\u003cp\u003eThe driver supplies up to 100 mA continuous current at a minimum output voltage of 13 VDC to actuate field solenoids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs an external auxiliary power supply required to operate this driver channel?\u003c\/p\u003e\n\u003cp\u003eThe driver loop operates directly from the 24 VDC control input signal, eliminating the need for a separate auxiliary power connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens to the hazardous area output if the safe-area control signal drops?\u003c\/p\u003e\n\u003cp\u003eWhen control voltage drops below threshold level, output current collapses immediately to zero, returning the field valve to its safe de-energized position.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the device support line fault transparency for field cable break detection?\u003c\/p\u003e\n\u003cp\u003eLine fault monitoring detects open-circuit or short-circuit conditions on field lines and mirrors the fault status back to the control system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is electrical separation maintained between the logic input and field output?\u003c\/p\u003e\n\u003cp\u003eGalvanic isolation rated at 2.5 kV AC prevents potential surges from propagating between safe-area control logic and hazardous field wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat maximum wire cross-section can be terminated into the pluggable terminals?\u003c\/p\u003e\n\u003cp\u003ePluggable terminal blocks accept solid or stranded copper conductors up to a maximum cross-sectional area of 2.5 mm square.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the driver be mounted horizontally inside a crowded control cabinet?\u003c\/p\u003e\n\u003cp\u003eVertical DIN-rail mounting is recommended to optimize convection airflow and ensure operation within specified ambient thermal limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the unit protect against field wiring short circuits?\u003c\/p\u003e\n\u003cp\u003eInternal current-limiting electronics clamp output current to safe levels during field short-circuits, preventing module damage or thermal hazards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Pepperl+Fuchs","offers":[{"title":"Default Title","offer_id":47508764164269,"sku":"KFD2-SLD-EX1.13100","price":381.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/kfd2-sl2-ex1.lk_1.jpg?v=1789090639","url":"https:\/\/www.maxwellplc.com\/ru\/products\/kfd2-sld-ex1-13100-pepperl-fuchs-solenoid-driver-k-system","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}