{"product_id":"ics-triplex-t9110-aadvance-processor-module","title":"ICS Triplex T9110 AADvance Processor Module","description":"\u003cp\u003eThe \u003cstrong\u003eICS Triplex T9110\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eT9110\u003c\/strong\u003e Processor Module, operates as a dedicated hardware component for safety-critical logic execution within AADvance safety instrumented system networks.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e ICS Triplex (Rockwell Automation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model:\u003c\/strong\u003e T9110\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Platform:\u003c\/strong\u003e AADvance Functional Safety System\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Central Processing Unit \/ Processor Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Configuration:\u003c\/strong\u003e DIN-rail backplane interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eT9110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICS Triplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited Kingdom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4.0 cm x 12.3 cm x 16.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e10.0 cm x 18.0 cm x 22.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eNatural convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Integrity Level\u003c\/td\u003e\n\u003ctd\u003eIEC 61508 SIL 2 \/ SIL 3 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Architecture\u003c\/td\u003e\n\u003ctd\u003e1oo1 (Simplex), 1oo2 (Dual), 2oo3 (TMR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eSNCP, Modbus TCP, Modbus RTU, TCP\/UDP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming Languages\u003c\/td\u003e\n\u003ctd\u003eIEC 61131-3 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Location Certifications\u003c\/td\u003e\n\u003ctd\u003eATEX, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSafety Instrumented System Architecture \u0026amp; TMR Execution\u003c\/h3\u003e\n\u003cp\u003eThe T9110 Processor Module delivers functional safety execution compliant with IEC 61508 up to SIL 3 application limits. The hardware architecture executes voter logic dynamically across single, dual, or triple modular redundancy (TMR) arrays without requiring customized application programming. Internal hardware-based diagnostics continuously monitor logic states and memory integrity to guarantee fail-safe state execution or continuous operation during single-fault conditions. Galvanic isolation circuits protect internal processing logic against external field loop transients.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x ICS Triplex T9110 Processor Module\u003c\/li\u003e\n\u003cli\u003e1x Installation and Hardware Reference Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the module directly onto the dedicated AADvance DIN-rail backplane assembly until the locking mechanisms fully engage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Clearance:\u003c\/strong\u003e Maintain vertical convection pathways with a minimum of 50 mm clearance above and below the module enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Bond the backplane chassis ground directly to the primary protective earth (PE) bus using a low-impedance conductor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Terminate all industrial communication network cables using 360-deg braid shielding connections at the cabinet entry point.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat redundancy modes does the T9110 processor support?\u003c\/p\u003e\n\u003cp\u003eThe T9110 supports user-configurable 1oo1 (Simplex), 1oo2 (Dual), and 2oo3 (Triple Modular Redundancy) configurations without specialized application code modifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat functional safety certifications are held by the T9110 module?\u003c\/p\u003e\n\u003cp\u003eThe module is certified under IEC 61508 for use in safety-instrumented functions up to SIL 2 in simplex and SIL 3 in redundant architectural setups.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhich communication protocols are natively supported by the processor?\u003c\/p\u003e\n\u003cp\u003eNative protocol support includes Rockwell Safe Network Control Protocol (SNCP), Modbus TCP, Modbus RTU, and standard TCP\/UDP industrial network interfaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is heat dissipated from the T9110 enclosure?\u003c\/p\u003e\n\u003cp\u003eThermal management relies strictly on natural convection cooling, eliminating mechanical fans and active cooling failures in high-dust enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat programming standard is utilized for control logic development?\u003c\/p\u003e\n\u003cp\u003eLogic development for the T9110 is executed within environment toolsets adhering to standard IEC 61131-3 programming languages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the physical dimensions of the T9110 Processor Module?\u003c\/p\u003e\n\u003cp\u003eThe physical envelope measures exactly 4.0 cm x 12.3 cm x 16.2 cm with total hardware mass rated at 0.36 kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the processor operate in hazardous locations?\u003c\/p\u003e\n\u003cp\u003eYes, the hardware carries official ATEX and UL certification approvals for deployment in classified hazardous industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the processor support hot-swapping inside a redundant array?\u003c\/p\u003e\n\u003cp\u003eWhen deployed in multi-processor redundant arrays, fault isolation allows module replacement without interrupting active safety logic execution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45519064826029,"sku":"T9110","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ics-triplex-t9110-processor-module-grwezund1un-2.jpg?v=1788311616","url":"https:\/\/www.maxwellplc.com\/ru\/products\/ics-triplex-t9110-aadvance-processor-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}